Impact of lung density on isolated lung tumor dose in VMAT using inline MR-Linac

被引:0
|
作者
Ohno, Takeshi [1 ]
Araki, Fujio [1 ]
Anami, Naoki [2 ]
Kubota, Takahiro [2 ,3 ]
Yano, Masayuki [4 ]
Ito, Shotaro [5 ]
机构
[1] Kumamoto Univ, Fac Life Sci, Dept Hlth Sci, 4-24-1 Kuhonji, Kumamoto, Japan
[2] Kumamoto Univ, Grad Sch Hlth Sci, 4-24-1 Kuhonji, Kumamoto, Japan
[3] Kokura Mem Hosp, 3-2-1 Asano, Kokura, Fukuoka, Japan
[4] Saga Heavy Ion Med Accelerator Tosu, 3049 Koga Machi, Tosu, Saga, Japan
[5] Natl Hosp Org Kyushu Med Ctr, 1-8-1 Jigyouhama, Fukuoka, Japan
关键词
MR-Linac; Isolated lung tumor; Lung density; Monte Carlo method; MAGNETIC-FIELDS; RADIOTHERAPY; DISTRIBUTIONS; VERIFICATION; ENHANCEMENT; DOSIMETRY; ELECTRON; BEAM;
D O I
10.1016/j.ejmp.2020.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the impact of lung density on the isolated lung tumor dose for volumetric modulated arc therapy (VMAT) in an inline magnetic resonance linear accelerator (MR-Linac) using the Monte Carlo (MC) simulation. Methods: CT images of the thorax phantoms with lung tumors of 1, 2, and 3 cm diameters were converted into voxel-base phantoms with lung densities of 0.1, 0.2, and 0.3 g/cm(3), respectively. The dose distributions were calculated for partial-arc VMAT. The dose distributions were compared using dose differences, dose volume histograms, and dose volume indices. Results: In all cases, the inline magnetic field significantly enhanced the lung tumor dose compared to that at 0 T. For the 1 cm lung tumor, the inline magnetic field of 1 T increased the minimum dose of 95% of the Planning target volume (PTV D-95) by 14.0% in 0.1 g/cm(3) ling density as compared to that in 0.3 g/cm(3) at 0 T. In contrast, at 0 and 0.5 T, the PTV D-95 in 0.3 g/cm(3) lung density was larger than that in lung density of 0.1 g/cm(3). For the 2 cm lung tumor, a similar tendency to 1 cm was observed, whereas the dose impact of lung density was smaller than that for 1 cm. For the 3 cm lung tumor, the lung tumor dose was independent of lung density at 0.5 T and 1.0 T. Conclusion: The inline MR-Linac with the magnetic field over 1 T can enhance the PTV D-95 for VMAT regardless of the lung density.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 50 条
  • [1] Impact of inline magnetic fields on dose distributions for VMAT in lung tumor
    Kubota, Takahiro
    Araki, Fujio
    Ohno, Takeshi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 100 - 106
  • [2] Comparison of treatment plans between IMRT with MR-linac and VMAT for lung SABR
    Jong Min Park
    Hong-Gyun Wu
    Hak Jae Kim
    Chang Heon Choi
    Jung-in Kim
    Radiation Oncology, 14
  • [3] Comparison of treatment plans between IMRT with MR-linac and VMAT for lung SABR
    Park, Jong Min
    Wu, Hong-Gyun
    Kim, Hak Jae
    Choi, Chang Heon
    Kim, Jung-in
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [4] MR-linac is the best modality for lung SBRT
    Godley, Andrew
    Zheng, Dandan
    Rong, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 7 - 11
  • [5] The Dosimetric Impact of Magnetic Field on Lung Cancer Treatment When Using MR-Linac
    Ding, C.
    Godley, A.
    Westover, K.
    Timmerman, R.
    Park, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] First experimental demonstration of VMAT combined with MLC tracking for single and multi fraction lung SBRT on an MR-linac
    Uijtewaal, Prescilla
    Borman, Pim T. S.
    Woodhead, Peter L.
    Kontaxis, Charis
    Hackett, Sara L.
    Verhoeff, Joost
    Raaymakers, Bas W.
    Fast, Martin F.
    RADIOTHERAPY AND ONCOLOGY, 2022, 174 : 149 - 157
  • [7] First VMAT delivery with MLC-tracking for single and multi fraction lung SBRT on a Unity MR-linac
    Uijtewaal, P.
    Borman, P.
    Woodhead, P.
    Kontaxis, C.
    Hackett, S.
    Verhoeff, J.
    Raaymakers, B.
    Fast, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S479 - S480
  • [8] Isotoxic Dose Escalation with Real-Time Imaging on an MR-Linac in Lung Radiation Therapy
    Bendall, L.
    Papiez, B. W.
    Hawkins, M. A.
    Fenwick, J. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S207 - S207
  • [9] Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking
    Menten, Martin J.
    Fast, Martin F.
    Nill, Simeon
    Kamerling, Cornelis P.
    McDonald, Fiona
    Oelfke, Uwe
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 461 - 466
  • [10] Measurement of Dose at Interfaces Using a Heterogeneous Phantom in a MR-Linac
    Ahmad, S.
    Paudel, M.
    Sahgal, A.
    Sarfehnia, A.
    Keller, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E551 - E551