Dynamic Performance of Flush End-Plate Beam-Column Connections and Design Applications in Progressive Collapse

被引:48
|
作者
Liu, Chang [1 ]
Fung, Tat Ching [1 ]
Tan, Kang Hai [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
Dynamic behavior; Flush end-plate connections; Experiments; Sudden column-removal scenario; Dynamic increase factor; Finite-element simulations; Dynamic effects; REMOVAL SCENARIO; RESISTANCE; BUILDINGS; BEHAVIOR;
D O I
10.1061/(ASCE)ST.1943-541X.0001329
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental program was conducted in this study to investigate the dynamic behavior of flush end plate steel beam-column cruciform connections following instantaneous removal of a central supporting column. The dynamic tests were performed by using a quick-release mechanism to simulate sudden column-removal scenarios. In the test program, the geometries of the flush end-plate connections remained unchanged but subjected to five different magnitudes of uniformly distributed load. Another five quasi-static tests were also carried out for comparison with the dynamic response and investigation of the dynamic increase factors (DIF). Test results showed that the release-time durations of the column support force were approximately 30 ms for all five dynamic tests. For the same initial applied dead loads, the maximum dynamic displacement was significantly increased compared to the corresponding quasi-static displacement. In order to observe the full dynamic performance of the tested connection until final failure, a general-purpose finite-element software was used to conduct the three-dimensional numerical simulations. Comparison results showed that the numerical model could accurately simulate the monotonic quasi-static test results and the dynamic test results under sudden column removal. Subsequently, a series of parametric studies was conducted to investigate the connection behavior considering the load-release time, different loading methods, and the magnitude of uniform distributed load. By comparing the full dynamic response of the flush end-plate connection with its corresponding quasi-static response, both the displacement-based DIF and force-based DIF could be respectively determined. The paper also addresses which DIF is more appropriate for the design of structures to resist progressive collapse. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Progressive collapse resistance of precast concrete beam-column sub-assemblages with high-performance dry connections
    Qian, Kai
    Liang, Shi-Lin
    Fu, Feng
    Fang, Qin
    [J]. ENGINEERING STRUCTURES, 2019, 198
  • [42] Dynamic performance of composite beam-column connections subjected to impact loadings
    Wang, Haitao
    Huo, Jingsi
    Liu, Yanzhi
    Elchalakani, Mohamed
    Zhu, Zhengxi
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 178
  • [43] Test on seismic behaviors of stainless steel bolted extended end-plate beam-column joints
    Zheng, Baofeng
    Wu, Dianhan
    Wang, Jiachang
    Shu, Ganping
    [J]. THIN-WALLED STRUCTURES, 2024, 196
  • [44] Study on The End-plate and Angle of Semi-rigid Connection in The Steel Frame of Beam-column
    Xu, Ling
    Liu, Shuai
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 872 - +
  • [45] Performance of practical beam-to-SHS column connections against progressive collapse
    Wang, Wei
    Fang, Cheng
    Qin, Xi
    Chen, Yiyi
    Li, Ling
    [J]. ENGINEERING STRUCTURES, 2016, 106 : 332 - 347
  • [46] Cyclic testing of flush end-plate semi-rigid steel connections
    Broderick, BM
    Thomson, AW
    [J]. BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 135 - 140
  • [47] Study on neutral axis location of common bolts of flush end-plate connections
    Wang, Anlian
    Zhang, Zhiwen
    Ji, Jialong
    Liu, Yan
    [J]. RESULTS IN ENGINEERING, 2022, 16
  • [48] Initial rotational stiffness of minor-axis flush end-plate connections
    Pan, Jianrong
    Chen, Shizhe
    Wang, Zhan
    Lu, Hui
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (01):
  • [49] Study on neutral axis location of common bolts of flush end-plate connections
    Wang, Anlian
    Zhang, Zhiwen
    Ji, Jialong
    Liu, Yan
    [J]. RESULTS IN ENGINEERING, 2022, 16
  • [50] Fire Response of Steel Column Trees with End-Plate Connections
    Rezaeian, Abbas
    Eghbali, Sobhan
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (10)