Influence of implant number on the movement of mandibular implant overdentures

被引:17
|
作者
Oda, Ken [1 ]
Kanazawa, Manabu [2 ]
Takeshita, Shin [2 ]
Minakuchi, Shunsuke [3 ]
机构
[1] Tokyo Med & Dent Univ, Gerodontol & Oral Rehabil, Grad Sch Med & Dent Sci, Bunkyo Ku, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Gerodontol & Oral Rehabil, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Gerodontol & Oral Rehabil, Bunkyo Ku, Tokyo, Japan
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2017年 / 117卷 / 03期
基金
日本学术振兴会;
关键词
QUALITY-OF-LIFE; SUPPORTED OVERDENTURE; SINGLE IMPLANT; IN-VITRO; OUTCOMES; BALL; BAR;
D O I
10.1016/j.prosdent.2016.08.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The rotational movement of an implant overdenture (IOD) has a negative effect on the perceived masticatory ability of the denture wearer. However, the influence of implant number on the movement of IODs has not been investigated. Purpose. The purpose of this in vitro study was to evaluate the denture movement of mandibular IODs anchored by different numbers of implants. Material and methods. An edentulous mandibular test model with artificial mucosa and 5 experimental overdentures (N=5) was fabricated. The locator attachment system with blue nylon inserts was chosen for this study. Three implant positions were prepared: anterior midline (1-IOD), bilateral lateral incisor regions (2-IOD), and anterior midline and bilateral canine regions (3-IOD). Vertical loads of 50 N were applied to the mid-anterior region, the left canine region, the left premolar region, and the left first molar region. The vertical and horizontal displacements at the right distal edge and the vertical displacements at the loading point were measured. The displacement values were statistically analyzed using a 1-way analysis of variance and the post hoc Tukey honest significant difference test with the implant number as a factor. In addition, the values of the vertical and horizontal displacements at the distal edge of the overdenture were statistically compared using a paired t test, and the values of the vertical displacement at the distal edge of the overdenture were statistically analyzed by a repeated measures analysis of variance and the post hoc Tukey honest significance difference test with the loading point as a 'factor (a=.05). Results. Upon anterior loading, the 2-IOD showed significantly larger vertical displacements at the right distal edge than the 1-IOD or 3-IOD (P<.01). The horizontal displacements at the right distal edge were small compared with the vertical displacements at the same point, although the displacement of the 2-IOD was significantly larger than that of the 1-IOD upon anterior loading (P=.03). The magnitude of the vertical displacement at the loading point of the 2-IOD was significantly larger than that of the 3-IOD upon anterior loading (P<.01). No statistically significant differences were shown under the other conditions for each loading (P>.05). Conclusions. Within the limitations of this in vitro study, the following conclusions were drawn: During mastication with the anterior teeth, the use of 2 implants for anchoring an IOD increased the rotation of the denture base more than the use of 1 or 3 implants. The horizontal movements of the IODs were small compared with the vertical movements. Denture movement under the occlusal force in the molar region was smaller than that in the anterior region.
引用
收藏
页码:380 / 385
页数:6
相关论文
共 50 条
  • [41] A comparison of the effect of different occlusal forms in mandibular implant overdentures
    Khamis, MM
    Zaki, HS
    Rudy, TE
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (04): : 422 - 429
  • [42] Prosthetic maintenance of different mandibular implant overdentures: A systematic review
    Assaf, Andre
    Daas, Marwan
    Boittin, Adeline
    Eid, Nicolas
    Postaire, Michel
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02): : 144 - 152
  • [43] Influence of implant distribution on the biomechanical behaviors of mandibular implant-retained overdentures: a three-dimensional finite element analysis
    Liao, Xiaoling
    Cao, Ruitao
    Zhong, Juan
    Chen, Chunxia
    Pan, Shaoxia
    BMC ORAL HEALTH, 2024, 24 (01)
  • [44] Influence of Implant Distribution and Palatal Coverage on the Strain of Splinted Implant and Overdenture in Maxillary Implant Overdentures
    Nishimura, Yuichi
    Takahashi, Toshihito
    Gonda, Tomoya
    Ikebe, Kazunori
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 281 - 288
  • [45] Effect of Implant Angulation on Attachment Retention in Mandibular Two-Implant Overdentures: A Clinical Study
    Jabbour, Zaher
    Fromentin, Olivier
    Lassauzay, Claire
    Nader, Samer Abi
    Correa, Jose A.
    Feine, Jocelyne
    de Albuquerque, Rubens F., Jr.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (04) : 565 - 571
  • [46] COST-EFFECTIVENESS OF IMPLANT-RETAINED MANDIBULAR OVERDENTURES
    VANDERWIJK, P
    BOUMA, J
    VANOORT, RP
    VANWAAS, MAJ
    RUTTEN, FFH
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 384 - 384
  • [47] Influence of Number of Implants and Connection Systems on Stress Behaviour of Mandibular Implant-retained overdentures: Photoelastic and Strain Gauge Analysis
    Campaner, Marcio
    Mendes Borges, Anna Clara
    Camargo, Danielle de Almeida
    Mazza, Leticia Cerri
    Bitencourt, Sandro Basso
    de Medeiros, Rodrigo Antonio
    Goiato, Marcelo Coelho
    Pesqueira, Aldieris Alves
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (05) : ZC04 - ZC09
  • [48] Does number of implants or type of attachment affect patient satisfaction with implant-retained mandibular overdentures?
    Kucukkurt, S.
    Tukel, H. C.
    JOURNAL OF OSSEOINTEGRATION, 2020, 12 (02) : 154 - 160
  • [49] Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures
    Takahashi, Toshihito
    Gonda, Tomoya
    Tomita, Akiko
    Mizuno, Yoko
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E43 - E48
  • [50] Patient Satisfaction with Maxillary 3-Implant Overdentures Using Different Attachment Systems Opposing Mandibular 2-Implant Overdentures
    Al-Zubeidi, Mohammed I.
    Alsabeeha, Nabeel H. M.
    Thomson, W. Murray
    Payne, Alan G. T.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e11 - e19