Comprehensive device simulation modeling of heavily irradiated silicon detectors at cryogenic temperatures

被引:8
|
作者
Moscatelli, F [1 ]
Santocchia, A
MacEvoy, B
Hall, G
Passeri, D
Petasecca, M
Pignatel, GU
机构
[1] Ist Nazl Fis Nucl, I-06123 Perugia, Italy
[2] Univ Perugia, Dipartimento Ingn Elett & Informaz, I-06125 Perugia, Italy
[3] Univ London Imperial Coll Sci Technol & Med, High Energy Phys Grp, London SW7 2BW, England
关键词
cryogenic temperatures; device simulation; particle physics; radiation damage effects;
D O I
10.1109/TNS.2004.832602
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radiation hardness is a critical design concern for present and future silicon detectors in high energy physics. Tracking systems at the CERN Large Hadron Collider (LHC) are expected to operate for ten years and to receive fast hadron fluences equivalent to 10(15)cm(-2) 1-MeV neutrons. Recently, low temperature operating conditions have been suggested as a means of suppressing the negative effects of radiation damage on detector charge collection properties. To investigate this effect, simulations have been carried out using the ISE-TCAD DESSIS device simulator. The so-called "three-level model" has been used. A comprehensive analysis of the influence of the V-2, CiOi and V2 0 capture cross sections on the effective doping concentration (N-eff) as a function of temperature and fluence has been carried out. The capture cross sections have been varied in the range 10(-18) - 10(-12) cm(2). The simulated results are compared with charge collection spectra obtained with 1064-mn laser pulses on devices irradiated with 23-GeV protons as a function of detector bias voltage. To validate the model, a wide range of temperature and fluence has been studied using a one-dimensional (1-D) simplified structure. Thousands of simulation results have been cross checked with the experimental data. The data between 190 K (the lower limit for simulations due to computational difficulties) and 290 K are well reproduced for all of the fluences considered. We conclude that the three-level model can be successfully used to predict irradiated detector behavior down to a temperature of at least 190 K.
引用
收藏
页码:1759 / 1765
页数:7
相关论文
共 50 条
  • [21] MODELING AND SIMULATION OF CHARGE COLLECTION PROPERTIES FOR NEUTRON-IRRADIATED SILICON DETECTORS
    LI, Z
    KRANER, HW
    NUCLEAR PHYSICS B, 1993, : 398 - 409
  • [22] Comprehensive modeling of silicon microstrip detectors
    Passeri, D
    Ciampolini, P
    Baroncini, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 598 - 605
  • [23] Comprehensive modeling of silicon microstrip detectors
    Passeri, D
    Ciampolini, P
    Baroncini, M
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 118 - 122
  • [24] Temperature dependence of the charge collection efficiency in heavily irradiated silicon detectors
    Bell, WH
    Casagrande, L
    Da Via, C
    Granata, V
    Palmieri, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (1-2): : 187 - 193
  • [25] Operation of heavily irradiated silicon detectors in non-depletion mode
    Verbitskaya, E
    Eremin, V
    Ilyashenko, I
    Li, Z
    Härkönen, J
    Tuovinen, E
    Luukka, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 557 (02): : 528 - 536
  • [26] Temperature dependence of the charge collection efficiency in heavily irradiated silicon detectors
    Bell, William H.
    Casagrande, Luca
    Da Via, Cinzia
    Granata, Valeria
    Palmieri, Vittorio G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 435 (1-2): : 187 - 193
  • [27] Test results on heavily irradiated silicon detectors for the CMS experiment at LHC
    Bozzi, C
    Albergo, S
    Angarano, MM
    Azzi, P
    Babucci, E
    Bacchetta, N
    Bader, A
    Bagliesi, G
    Bartalini, P
    Basti, A
    Biggeri, U
    Bilei, GM
    Bisello, D
    Boemi, D
    Bosi, F
    Borrello, L
    Braibant, S
    Breuker, H
    Bruzzi, M
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Creanza, D
    D'Alessandro, R
    Da Rold, M
    Demaria, N
    de Palma, M
    Dell'Orso, R
    Della Marina, R
    Dutta, S
    Eklund, C
    Elliott-Peisert, A
    Feld, L
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Fürtjes, A
    Giassi, A
    Giraldo, A
    Glessing, B
    Gu, WH
    Hall, G
    Hammerstrom, R
    Hebbeker, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2092 - 2100
  • [28] Simulation of signal in irradiated silicon pixel detectors
    Kramberger, G
    Contarato, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 82 - 87
  • [29] The impact of active base on the bulk current in silicon heavily irradiated detectors
    Eremin, V.
    Fadeeva, N.
    Verbitskaya, E.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [30] Interdefect charge exchange in silicon particle detectors at cryogenic temperatures
    MacEvoy, B
    Santocchia, A
    Hall, G
    Moscatelli, F
    Passeri, D
    Bilei, GM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1750 - 1755