Generating multiple independent retention index data in dual-secondary column comprehensive two-dimensional gas chromatography

被引:46
|
作者
Bieri, Stefan [1 ]
Marriott, Philip J. [1 ]
机构
[1] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3001, Australia
关键词
D O I
10.1021/ac060869l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach ( GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/ siloxane (BPX5) and 14% cyanopropylphenyl/ 86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which Kovats indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction ( SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index information in comprehensive 2D-GC.
引用
收藏
页码:8089 / 8097
页数:9
相关论文
共 50 条
  • [1] Methods for generating second dimension retention index data in comprehensive two-dimensional gas chromatography
    Western, RJ
    Marriott, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) : 3 - 14
  • [2] A dual-secondary column comprehensive two-dimensional gas chromatograph for the analysis of volatile organic compound mixtures
    Seeley, JV
    Kramp, FJ
    Sharpe, KS
    [J]. JOURNAL OF SEPARATION SCIENCE, 2001, 24 (06) : 444 - 450
  • [3] Characterization of gaseous mixtures of organic compounds with dual-secondary column comprehensive two-dimensional gas chromatography (GC x 2GC)
    Seeley, JV
    Kramp, FJ
    Sharpe, KS
    Seeley, SK
    [J]. JOURNAL OF SEPARATION SCIENCE, 2002, 25 (1-2) : 53 - 59
  • [4] Identification of unknown compounds on the basis of retention index data in comprehensive two-dimensional gas chromatography
    Pang, Tao
    Zhu, Shukui
    Lu, Xin
    Xu, Guowang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 868 - 874
  • [5] Retention indices in comprehensive two-dimensional gas chromatography
    von Muehlen, Carin
    Marriott, Philip J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2351 - 2360
  • [6] Retention indices in comprehensive two-dimensional gas chromatography
    Carin von Mühlen
    Philip J. Marriott
    [J]. Analytical and Bioanalytical Chemistry, 2011, 401 : 2351 - 2360
  • [7] Alignment for Comprehensive Two-Dimensional Gas Chromatography with Dual Secondary Columns and Detectors
    Reichenbach, Stephen E.
    Rempe, Davis W.
    Tao, Qingping
    Bressanello, Davide
    Liberto, Erica
    Bicchi, Carlo
    Balducci, Stefano
    Cordero, Chiara
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (19) : 10056 - 10063
  • [8] A retention index system for comprehensive two-dimensional gas chromatography using polyethylene glycols
    Veenaas, Cathrin
    Haglund, Peter
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 : 67 - 74
  • [9] A procedure for comprehensive two-dimensional gas chromatography retention time locked dual detection
    Mommers, John
    Ritzen, Erik
    Dutriez, Thomas
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1461 : 153 - 160
  • [10] Evaluation of a retention model in comprehensive two-dimensional gas chromatography
    Vendeuvre, C
    Bertoncini, F
    Thiébaut, D
    Martin, M
    Hennion, MC
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1129 - 1136