Numerical simulation of transit-time ultrasonic flowmeters: uncertainties due to flow profile and fluid turbulence

被引:75
|
作者
Iooss, B
Lhuillier, C
Jeanneau, H
机构
[1] CEN Cadarache, DEN, DER, STR,LCFR, F-13108 St Paul Les Durance, France
[2] CEN Cadarache, DEN, DED, SCCD,LDMN, F-13108 St Paul Les Durance, France
[3] EDF, DRD, REME, F-78401 Chatou, France
关键词
ultrasonic flowmeter; transit time; turbulent flow; velocity; ray tracing; random media;
D O I
10.1016/S0041-624X(02)00387-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Flowmeter measurement using the ultrasonic transit-time method is based on the apparent difference of the sound velocity in the flow direction and in the opposite direction. This method gives a flow velocity averaged along a particular acoustical path. To convert this path velocity to a velocity averaged over the entire cross-section of the flowing medium, the knowledge of the flow velocity profile is essential, However, the acoustical paths joining the two transducers are supposed to be straight and fluid turbulence phenomena are neglected. In this paper. we describe a numerical procedure to estimate the uncertainties due to these approximations in the case of fully developed turbulence, The ultrasonic propagation is modelled in 2-D moving inhomogeneous media via a ray tracing algorithm. Influence of mean profiles of temperature and velocity is studied on simple examples, Fluid temperature fluctuations and fluid velocity turbulence are considered in the stochastic framework to obtain average uncertainties on the measurements of the liquid flow rate. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1009 / 1015
页数:7
相关论文
共 50 条
  • [21] Study on Transit-Time Ultrasonic Flow Meter with Waveform Analysis
    Li, Bin
    Lu, Jiwei
    Chen, Jie
    Chen, Siyuan
    2ND INTERNATIONAL CONFERENCE ON INFORMATION SYSTEM AND DATA MINING (ICISDM 2018), 2018, : 146 - 150
  • [22] AN IMPLANTABLE TRANSIT-TIME ULTRASONIC BLOOD-FLOW METER
    BARNES, RJ
    COMLINE, RS
    DOBSON, A
    DROST, CJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1983, 345 (DEC): : P2 - P3
  • [23] ULTRASONIC METERING OF FLOW VELOCITY BASED ON TRANSIT-TIME DIFFERENTIALS
    TABIN, J
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (05): : 559 - 561
  • [24] A Fault-Tolerant Flow Measuring Method Based on PSO-SVM With Transit-Time Multipath Ultrasonic Gas Flowmeters
    Tang, Xiaoyu
    Xie, Xiang
    Fan, Bo
    Sun, Youxian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (05) : 992 - 1005
  • [25] Minimizing the Zero-Flow Error in Transit-Time Ultrasonic Flow Meters
    van Willigen, Douwe
    van Neer, Paul
    Massaad, Jack
    Verweij, Martin
    de Jong, Nicolaas
    Pertijs, Michiel
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [26] Estimation of the flow profile correction factor of a transit-time ultrasonic flow meter for the feedwater flow measurement in a nuclear power plant
    Jung, JC
    Seong, PH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 714 - 718
  • [27] Studies on the transducers of Clamp-on Transit-time Ultrasonic Flow meter
    Han, Jianping
    Liu, Hao
    Zhou, Yuanyuan
    Zhang, Rumei
    Li, Changji
    2014 4TH IEEE INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY (ICIST), 2014, : 180 - 183
  • [28] Numerical Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment
    Alidoosti, Elaheh
    Ma, Jian
    Jiang, Yingtao
    Moazzeni, Taleb
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [29] MEASUREMENT OF TIDAL FLOW USING A TRANSIT-TIME ULTRASONIC BREATH ANALYZER
    WILLIAMS, EM
    BURROUGH, SLM
    MCPEAK, H
    ANAESTHESIA, 1995, 50 (05) : 427 - 432
  • [30] IN-VIVO VALIDATION OF A TRANSIT-TIME ULTRASONIC VOLUME FLOW METER
    HARTMAN, JC
    OLSZANSKI, DA
    HULLINGER, TG
    BRUNDEN, MN
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1994, 31 (03) : 153 - 160