Performance of Innovative Precast Concrete Sleepers Prestressed with Glass Fiber-Reinforced Polymer Reinforcing Bars

被引:5
|
作者
Hadhood, Abdeldayem [1 ]
Mohamed, Hamdy M. [1 ]
Mwiseneza, Celestin [1 ]
Benmokrane, Brahim [2 ,3 ,4 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ, Canada
[2] Univ Sherbrooke, Dept Civil Engn, Civil Engn, Sherbrooke, PQ, Canada
[3] Univ Sherbrooke, Dept Civil Engn, FRP Reinforcement Concrete Infrastruct, Sherbrooke, PQ, Canada
[4] Univ Sherbrooke, Dept Civil Engn, Adv Composite Mat Civil Struct, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
American Railway Engineering and Maintenance-of-Way Association (AREMA); glass fiber-reinforced polymer (GFRP) bars; monoblock ties; prestressed; prestressing; railway; sleepers; RAILWAY SLEEPERS;
D O I
10.14359/51728186
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Replacing defective reinforced concrete railway sleepers has reportedly been urged by several businesses and maintenance agencies. The harsh environmental conditions, especially in North America, trigger material degradation and steel corrosion. Glass fiber-reinforced polymer (GFRP) bars have been increasingly used in a wide variety of applications. The present study presents an original, promising application of GFRP as prestressed reinforcement in concrete railway sleepers. For prestressed GFRP sleepers to be accepted as replacements for defective sleepers made with timber and concrete, they must pass several short- and long-term tests. Full-scale GFRP- and steel-reinforced concrete sleepers were designed, tested, and compared according to the requirements of the American Railway Engineering and Maintenance-of-Way Association (AREMA). The test results show that GFRP- and steel-reinforced concrete sleepers achieved similar cracking levels and ultimate loads in the rail-seat negative and positive tests. The tested GFRP specimens met AREMA s requirements for static and fatigue loading for use in freight and commuter rail systems with the designated loads, spacings, and train speed used in this study. The failure of the prestressed GFRP-RC sleepers was governed by shear-compression failure, while the prestressed steel-RC sleepers failed by crushing of the concrete due to the slippage of steel strands. Moreover; field inspection of GFRP-rein forced concrete sleepers after 3 years under actual service conditions reveal very competitive performance and no cracks. Lastly, the results of this study constitute a basic step toward establishing code provisions for using GFRP bars as prestressing reinforcement in concrete sleepers for railway applications.
引用
收藏
页码:277 / 288
页数:12
相关论文
共 50 条
  • [1] Durability of glass fiber-reinforced polymer reinforcing bars in concrete environment
    Benmokrane, B
    Wang, P
    Ton-That, TM
    Rahman, H
    Robert, JF
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (03) : 143 - 153
  • [2] Interface of Ultra-High-Performance Concrete with Steel, Glass Fiber-Reinforced Polymer, and Basalt Fiber-Reinforced Polymer Reinforcing Bars
    Kim, Yail J.
    Wang, Jun
    ACI STRUCTURAL JOURNAL, 2022, 119 (03) : 3 - 15
  • [3] Lightweight Concrete Precast Bridge Deck Panels Reinforced with Glass Fiber-Reinforced Polymer Bars
    Pantelides, Chris P.
    Liu, Ruifen
    Reaveley, Lawrence D.
    ACI STRUCTURAL JOURNAL, 2012, 109 (06) : 879 - 888
  • [4] Flexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars
    Lee, Won K.
    Jansen, Daniel C.
    Berlin, Kenneth B.
    Cohen, Ian E.
    ACI STRUCTURAL JOURNAL, 2010, 107 (03) : 321 - 329
  • [5] Precast high-performance concrete (HPC) sheet piles prestressed with glass fiber reinforced polymer (GFRP) bars
    Spagnuolo, S.
    Giorgi, C.
    Rinaldi, Z.
    Pedrocco, L.
    COMPOSITE STRUCTURES, 2023, 304
  • [6] Deformability and Stiffness Characteristics of Concrete Shear Walls Reinforced with Glass Fiber-Reinforced Polymer Reinforcing Bars
    Hassanein, Ahmed
    Mohamed, Nayera
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2020, 117 (01) : 183 - 196
  • [7] Tensile lap splicing of fiber-reinforced polymer reinforcing bars in concrete
    Aly, Ragi
    Benmokrane, Brahim
    Ebead, Usama
    ACI STRUCTURAL JOURNAL, 2006, 103 (06) : 857 - 864
  • [8] Fatigue tensile testing of glass fiber-reinforced polymer reinforcing bars
    D'Antino, Tommaso
    Pisani, Marco A.
    Poggi, Carlo
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 346
  • [9] Tensile lap splicing of fiber-reinforced polymer reinforcing bars in concrete
    Department of Civil Engineering, University of Sherbrooke, Sherbrooke, QC, Canada
    不详
    ACI Struct J, 2006, 6 (857-864):
  • [10] Performance of Glass Fiber-Reinforced Polymer Bent Bars
    Jeremic, Natasa
    Sheikh, Shamim A.
    ACI STRUCTURAL JOURNAL, 2021, 118 (02) : 273 - 285