MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T

被引:5
|
作者
Bian, Wei [1 ]
Kerr, Adam B. [2 ]
Tranvinh, Eric [3 ]
Parivash, Sherveen [3 ]
Zahneisen, Benjamin [3 ]
Han, May H. [4 ]
Lock, Christopher B. [4 ]
Goubran, Maged [3 ]
Zhu, Kongrong [2 ]
Rutt, Brian K. [3 ]
Zeineh, Michael M. [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Dept Biomed Engn, Chengdu, Sichuan, Peoples R China
[2] Stanford Univ, Dept Elect Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Radiol, Palo Alto, CA 94304 USA
[4] Stanford Univ, Sch Med, Dept Neurol & Neurol Sci, Palo Alto, CA 94304 USA
来源
PLOS ONE | 2019年 / 14卷 / 07期
基金
美国国家卫生研究院;
关键词
MULTIPLE-SCLEROSIS; HUMAN BRAIN; CORTICAL-LESIONS; TISSUE; T-1; CAIPIRINHA;
D O I
10.1371/journal.pone.0219705
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To develop a 7T simultaneous multi-slice (SMS) 2D gradient-echo sequence for susceptibility contrast imaging, and to compare its quality to 3D imaging. Methods A frequency modulated and phase cycled RF pulse was designed to simultaneously excite multiple slices in multi-echo 2D gradient-echo imaging. The imaging parameters were chosen to generate images with susceptibility contrast, including T-2*-weighted magnitude/phase images, susceptibility-weighted images and quantitative susceptibility/R-2* maps. To compare their image quality with 3D gradient-echo imaging, both 2D and 3D imaging were performed on 11 healthy volunteers and 4 patients with multiple sclerosis (MS). The signal to noise ratio (SNR) in gray and white matter and their contrast to noise ratio (CNR) was simulated for the 2D and 3D magnitude images using parameters from the imaging. The experimental SNRs and CNRs were measured in gray/white matter and deep gray matter structures on magnitude, phase, R-2* and QSM images from volunteers and the visibility of MS lesions on these images from patients was visually rated. All SNRs and CNRs were compared between the 2D and 3D imaging using a paired t-test. Results Although the 3D magnitude images still had significantly higher SNRs (by 13.0 similar to 17.6%), the 2D magnitude and QSM images generated significantly higher gray/white matter or globus pallidus/putamen contrast (by 13.3 similar to 87.5%) and significantly higher MS lesion contrast (by 5.9 similar to 17.3%). Conclusion 2D SMS gradient-echo imaging can serve as an alternative to often used 3D imaging to obtain susceptibility-contrast-weighted images, with an advantage of providing better image contrast and MS lesion sensitivity.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Slice-accelerated gradient-echo echo planar imaging dynamic susceptibility contrast-enhanced MRI with blipped CAIPI: effect of increasing temporal resolution
    Tomohiro Takamura
    Masaaki Hori
    Koji Kamagata
    Kanako K. Kumamaru
    Ryusuke Irie
    Akifumi Hagiwara
    Nozomi Hamasaki
    Shigeki Aoki
    Japanese Journal of Radiology, 2018, 36 : 40 - 50
  • [42] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 803 - 813
  • [43] Simultaneous multi-slice MR imaging of the hip at 3 T to reduce acquisition times and maintain image quality
    Mayuko Haraikawa
    Masashi Suzuki
    Kaiji Inoue
    Eito Kozawa
    Junji Tanaka
    Mamoru Niitsu
    BMC Musculoskeletal Disorders, 19
  • [44] Gradient-Echo EPI Using a High-Degree Shim Insert Coil at 7T: Implications for BOLD fMRI
    Kim, Tae
    Lee, Yoojin
    Zhao, Tiejun
    Hetherington, Hoby P.
    Pan, Jullie W.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1734 - 1745
  • [45] Cervical spinal cord multiple sclerosis: evaluation with 2D multi-echo recombined gradient echo MR imaging
    White, Matthew L.
    Zhang, Yan
    Healey, Kathleen
    JOURNAL OF SPINAL CORD MEDICINE, 2011, 34 (01): : 93 - 98
  • [46] RAPID T1 ESTIMATION USING TAGGED MAGNETIZATION-PREPARED GRADIENT-ECHO MR IMAGING
    NIITSU, M
    CAMPEAU, NG
    RIEDERER, SJ
    ANNO, I
    ITAI, Y
    MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (02) : 377 - 385
  • [47] Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques
    M.-J. Kim
    D. G. Mitchell
    K. Ito
    P. N. Kim
    Abdominal Imaging, 2001, 26 : 269 - 276
  • [48] Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques
    Kim, MJ
    Mitchell, DG
    Ito, K
    Kim, PN
    ABDOMINAL IMAGING, 2001, 26 (03): : 269 - 276
  • [49] Quantitative T*2-Mapping Based on Multi-Slice Multiple Gradient Echo FLASH Imaging: Retrospective Correction for Subject Motion Effects
    Magerkurth, Joerg
    Volz, Steffen
    Wagner, Marlies
    Jurcoane, Alina
    Anti, Sandra
    Seiler, Alexander
    Hattingen, Elke
    Deichmann, Ralf
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (04) : 989 - 997
  • [50] Simultaneous multi-slice MR imaging of the hip at 3T to reduce acquisition times and maintain image quality
    Haraikawa, Mayuko
    Suzuki, Masashi
    Inoue, Kaiji
    Kozawa, Eito
    Tanaka, Junji
    Niitsu, Mamoru
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19