Geometric optimization of a tissue pattern for semilunar valve reconstruction

被引:0
|
作者
Hanlon, JG
Suggit, RW
Gibbs, E
McMeeking, RM
Love, JW
机构
[1] CardioMend LLC, Santa Barbara, CA USA
[2] McLean Engn, Vancouver, BC, Canada
[3] Univ Calif Santa Barbara, Dept Mech Engn, Santa Barbara, CA 93106 USA
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: A novel geometric trefoil pattern has been suggested for semilunar valve reconstruction. Optimization of the geometry must rely on an appreciation of normal anatomy and knowledge of the mechanical properties of the tissue used for the reconstruction. Methods: Computer-assisted design (CAD) was used to create an optimized leaflet geometry based on published dimensions for normal human aortic valves. The optimized leaflet geometry was subjected to finite element analysis (FEA) to study stress distribution with pressure loading of the leaflet. In vitro function of the optimized trefoil tissue pattern is being studied by static testing initially, with physiological saline. Results: An optimized leaflet geometry has been developed by CAD, and further refined by FEA. Static testing of the optimized trefoil tissue pattern shows near-normal anatomy, with no prolapse or pin wheeling, and full valve competence to 90 mmHg pressure. Conclusions: An initial optimized geometry has been developed for a two-dimensional tissue pattern that can be used to reconstruct diseased semilunar heart valves with human pericardium. Optimization studies are based on the mechanical properties of the tissue, CAD to mimic normal anatomy, FEA to study stress distribution, and static load testing to confirm function.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 50 条
  • [31] LEAFLET MOTION OF TRILEAFLET SEMILUNAR VALVE IN ATRIOVENTRICULAR POSITION
    IMAMURA, E
    KAYE, MP
    DAVIS, GD
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1978, 42 (06): : 790 - 790
  • [32] EXPERIMENTAL REPLACEMENT OF PULMONIC VALVE WITH A TRICUSPID SEMILUNAR PROSTHESIS
    ROSS, J
    COOPER, T
    BROCKENBROUGH, EC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1961, 42 (03): : 371 - &
  • [33] MITRAL VALVE REPLACEMENT USING HOMOGRAFT SEMILUNAR VALVES
    ROSS, JK
    BRITISH HEART JOURNAL, 1971, 33 (01): : 145 - &
  • [34] Closed correction of systemic semilunar valve insufficiency in the neonate
    Pigula, FA
    Mahnke, CB
    Agnastopolous, P
    Casta, A
    Munoz, R
    Gandhi, SK
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (05): : 1650 - 1652
  • [35] MITRAL-VALVE REPLACEMENT USING FRESH UNSTENTED SEMILUNAR VALVE HOMOGRAFTS
    YACOUB, M
    SOMERVILLE, W
    TOWERS, M
    BRITISH HEART JOURNAL, 1972, 34 (02): : 207 - +
  • [36] A fractional calculus model of semilunar heart valve vibrations
    ElShahed, M
    CHALLENGING THE BOUNDARIES OF SYMBOLIC COMPUTATION, 2003, : 57 - 64
  • [37] ATRIOVENTRICULAR AND SEMILUNAR VALVE VASCULARIZATION IN RABBITS AND GUINEA PIGS
    SMITH, RB
    TAYLOR, IM
    ACTA ANATOMICA, 1971, 78 (01): : 1 - &
  • [38] RESULTS OF MITRAL VALVE REPLACEMENT USING UNSTENTED FRESH SEMILUNAR VALVE HOMOGRAFTS
    YACOUB, MH
    TOWERS, M
    SOMERVIL.W
    CIRCULATION, 1971, 44 (04) : 70 - &
  • [39] Hemodynamic study of the effect of the geometric height of leaflets on the performance of the aortic valve under aortic valve reconstruction
    Ma, Xinrui
    Gao, Bin
    Tao, Liang
    Ding, Jinli
    Li, Shu
    Qiao, Aike
    Chang, Yu
    JOURNAL OF THORACIC DISEASE, 2022, 14 (05) : 1515 - 1525
  • [40] Pattern Classification Based on Conformal Geometric Algebra and Optimization Techniques
    Cruz, Benjamin
    Barron, Ricardo
    Sossa, Humberto
    MICAI 2008: ADVANCES IN ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2008, 5317 : 273 - 283