Observer Variation in the Echocardiographic Measurement of Maximum Atrial Septal Excursion: A Comparison of M-Mode with Two-Dimensional or Transesophageal Echocardiography

被引:4
|
作者
Garg, Rajeev
Khaja, Azam
Madsen, Richard [2 ]
Alpert, Martin A.
Tejwani, Lokesh
Aggarwal, Kul [1 ,3 ]
机构
[1] Univ Missouri, Hlth Sci Ctr, Div Cardiol, Sch Med, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Off Med Res, Columbia, MO USA
[3] Harry S Truman Mem Vet Hosp, Cardiol Sect, Columbia, MO USA
关键词
maximum atrial septal excursion; M-mode echocardiography; two-dimensional echocardiography; transesophageal echocardiography; observer variation; atrial septal aneurysm; PATENT FORAMEN OVALE; CRYPTOGENIC STROKE; RISK-FACTORS; ANEURYSM; CLASSIFICATION; EVENTS; ADULTS;
D O I
10.1111/j.1540-8175.2009.00964.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial septal aneurysm is typically diagnosed by transthoracic two-dimensional or transesophageal echocardiography (2DE or TEE). Such techniques are highly dependent on visual inspection which predisposes to observer variation. This study compares inter-and intraobserver variations in the measurement of maximum atrial septal excursion (MASE) obtained using transthoracic M-mode echocardiography (MME) with that obtained using 2DE or TEE. Methods: Consecutive patients with highly mobile atrial septal motion by visual inspection during 2DE or TEE were studied. MASE was estimated visually on 2DE or TEE. MME tracings were obtained with the cursor bisecting the parabola formed by the atrial septum at its maximum deviation from the midline. Electronic calipers were used to measure MASE for all echocardiographic techniques. Two observers provided two measurements each. Observer variation was determined by assessing standard deviation and confidence intervals of inter-and intraobserver differences. Results: Interobserver analysis showed standard deviations of 0.077 cm (95% CI 0.065-0.094) for MME and 0.280 cm (95% CI 0.242-0.334) for 2DE or TEE. Intraobserver analysis showed standard deviations of 0.08 cm (95% CI 0.068-0.101) for MME and 0.318 cm (95% CI 0.274-0.381) for 2DE or TEE. The mean magnitude of measured MASE was 0.44 cm higher with MME than with 2DE or TEE (95% CI 0.068-0.101). Conclusions: MME assessment of MASE is associated with substantially lower inter-and intraobserver variation than 2DE or TEE assessment. The magnitude of MASE is substantially higher with MME than with 2DE or TEE. (ECHOCARDIOGRAPHY, Volume 26, November 2009)
引用
收藏
页码:1122 / 1126
页数:5
相关论文
共 50 条
  • [41] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC RECOGNITION OF AN ATRIAL SEPTAL ANEURYSM
    ILICETO, S
    ANTONELLI, G
    CHIDDO, A
    RIZZON, P
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1983, 2 (3-4) : 447 - 449
  • [42] En Face View of Atrial Septal Defect by Two-Dimensional Transthoracic Echocardiography: Comparison to Real-Time Three-Dimensional Transesophageal Echocardiography
    Huang, Xinsheng
    Shen, Junjun
    Huang, Yigao
    Zheng, Zhichao
    Fei, Hongwen
    Hou, Yueshuang
    Xu, Yan
    Huang, Tao
    Huang, Wenhui
    Zhang, Caojin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) : 714 - 721
  • [43] Evaluation of tricuspid annular plane systolic excursion measured by two-dimensional echocardiography in healthy dogs: repeatability, reference intervals, and comparison with M-mode assessment
    Visser, L. C.
    Sintov, D. J.
    Oldach, M. S.
    JOURNAL OF VETERINARY CARDIOLOGY, 2018, 20 (03) : 165 - 174
  • [44] IDENTIFICATION OF PROMINENT EUSTACHIAN VALVES BY M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY - DIFFERENTIATION FROM RIGHT ATRIAL MASSES
    BOMMER, WJ
    KWAN, OL
    MASON, DT
    DEMARIA, AN
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 402 - 402
  • [45] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY - CONTRIBUTIONS AND LIMITATIONS IN MANAGEMENT OF INTERATRIAL AND INTERVENTRICULAR SEPTAL-DEFECTS AND CONOTRUNCAL ANOMALIES
    BIERMAN, FZ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (06): : 721 - 734
  • [46] Comparison of transesophageal echocardiography and two-dimensional echocardiography in stroke evaluation
    Alkhersam, HH
    Cheema, ZF
    ANNALS OF NEUROLOGY, 1998, 44 (03) : 447 - 448
  • [47] Two-dimensional and M-mode echocardiographic measurements of cardiac dimensions in healthy standardbred trotters
    Bakos, Z
    Vörös, K
    Järvinen, T
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2002, 50 (03) : 273 - 282
  • [48] CLINICAL CORRELATES OF M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MITRAL-VALVE PROLAPSE
    ZUGIBE, FT
    NANDA, NC
    CLINICAL RESEARCH, 1983, 31 (02): : A228 - A228
  • [49] Two-dimensional, M-mode and left atrial velocity echocardiographic measurements in healthy Norwegian-Swedish Coldblooded Trotters
    Fintl, C.
    Krontveit, R.
    Risberg, A.
    Hanche-Olsen, S.
    Slack, J.
    JOURNAL OF VETERINARY CARDIOLOGY, 2020, 29 : 60 - 73
  • [50] Two-dimensional and M-mode echocardiographic reference values in healthy adult Saanen goats
    Leroux, A. A.
    Moonen, M. L.
    Farnir, F.
    Sandersen, C. F.
    Deleuze, S.
    Salciccia, A.
    Amory, H.
    VETERINARY RECORD, 2012, 170 (06) : 154 - U63