Observer Variation in the Echocardiographic Measurement of Maximum Atrial Septal Excursion: A Comparison of M-Mode with Two-Dimensional or Transesophageal Echocardiography

被引:4
|
作者
Garg, Rajeev
Khaja, Azam
Madsen, Richard [2 ]
Alpert, Martin A.
Tejwani, Lokesh
Aggarwal, Kul [1 ,3 ]
机构
[1] Univ Missouri, Hlth Sci Ctr, Div Cardiol, Sch Med, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Off Med Res, Columbia, MO USA
[3] Harry S Truman Mem Vet Hosp, Cardiol Sect, Columbia, MO USA
关键词
maximum atrial septal excursion; M-mode echocardiography; two-dimensional echocardiography; transesophageal echocardiography; observer variation; atrial septal aneurysm; PATENT FORAMEN OVALE; CRYPTOGENIC STROKE; RISK-FACTORS; ANEURYSM; CLASSIFICATION; EVENTS; ADULTS;
D O I
10.1111/j.1540-8175.2009.00964.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial septal aneurysm is typically diagnosed by transthoracic two-dimensional or transesophageal echocardiography (2DE or TEE). Such techniques are highly dependent on visual inspection which predisposes to observer variation. This study compares inter-and intraobserver variations in the measurement of maximum atrial septal excursion (MASE) obtained using transthoracic M-mode echocardiography (MME) with that obtained using 2DE or TEE. Methods: Consecutive patients with highly mobile atrial septal motion by visual inspection during 2DE or TEE were studied. MASE was estimated visually on 2DE or TEE. MME tracings were obtained with the cursor bisecting the parabola formed by the atrial septum at its maximum deviation from the midline. Electronic calipers were used to measure MASE for all echocardiographic techniques. Two observers provided two measurements each. Observer variation was determined by assessing standard deviation and confidence intervals of inter-and intraobserver differences. Results: Interobserver analysis showed standard deviations of 0.077 cm (95% CI 0.065-0.094) for MME and 0.280 cm (95% CI 0.242-0.334) for 2DE or TEE. Intraobserver analysis showed standard deviations of 0.08 cm (95% CI 0.068-0.101) for MME and 0.318 cm (95% CI 0.274-0.381) for 2DE or TEE. The mean magnitude of measured MASE was 0.44 cm higher with MME than with 2DE or TEE (95% CI 0.068-0.101). Conclusions: MME assessment of MASE is associated with substantially lower inter-and intraobserver variation than 2DE or TEE assessment. The magnitude of MASE is substantially higher with MME than with 2DE or TEE. (ECHOCARDIOGRAPHY, Volume 26, November 2009)
引用
收藏
页码:1122 / 1126
页数:5
相关论文
共 50 条
  • [1] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF ATRIAL SEPTAL-DEFECT
    CALABRO, MP
    RIVISTA ITALIANA DI PEDIATRIA-ITALIAN JOURNAL OF PEDIATRICS, 1982, 8 (06): : 853 - 854
  • [2] COMPARISON OF M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF ATRIAL-MYXOMA
    ROUDAUT, R
    LEGUIFFANT, C
    VIDEAU, P
    CLEMENTY, J
    CHOUSSAT, A
    DALLOCCHIO, M
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1980, 73 (07): : 775 - 784
  • [3] M-MODE AND TWO-DIMENSIONAL CONTRAST ECHOCARDIOGRAPHY IN ADULT PATIENTS WITH ATRIAL SEPTAL-DEFECTS
    GRENADIER, E
    ALPAN, G
    KEIDAR, S
    PALANT, A
    CLINICAL CARDIOLOGY, 1983, 6 (12) : 588 - 594
  • [4] DIFFERENCES BETWEEN M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    THYS, D
    HILLEL, Z
    ANESTHESIOLOGY, 1988, 68 (04) : 645 - 646
  • [5] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY OF PULMONARY EMBOLI
    ARVAN, S
    DUBOIS, B
    JOURNAL OF CLINICAL ULTRASOUND, 1982, 10 (04) : 177 - 179
  • [6] Two-dimensional and M-mode echocardiographic parameters in Ghezel sheep
    Roustaei, Ali
    Hashemi-Asl, Seyed Mohammad
    Dalir-Naghadeh, Bahram
    Masoudifard, Majid
    VETERINARY RESEARCH FORUM, 2021, 12 (03) : 349 - 355
  • [7] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FEATURES IN CARDIAC AMYLOIDOSIS
    SIQUEIRAFILHO, AG
    CUNHA, CLP
    TAJIK, AJ
    SEWARD, JB
    SCHATTENBERG, TT
    GIULIANI, ER
    CIRCULATION, 1981, 63 (01) : 188 - 196
  • [8] DIAGNOSIS OF TRICUSPID STENOSIS BY M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    SHIMADA, R
    TAKESHITA, A
    NAKAMURA, M
    TOKUNAGA, K
    HIRATA, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01): : 164 - 168
  • [9] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN CONGENITAL ABSENCE OF THE PERICARDIUM
    NICOLOSI, GL
    BORGIONI, L
    ALBERTI, E
    BURELLI, C
    MAFFESANTI, M
    MARINO, P
    SLAVICH, G
    ZANUTTINI, D
    CHEST, 1982, 81 (05) : 610 - 613
  • [10] STATISTICAL COMPARISON OF THE M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF FLAIL MITRAL LEAFLETS
    MINTZ, GS
    KOTLER, MN
    PARRY, WR
    SEGAL, BL
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 435 - 435