Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients

被引:49
|
作者
Monge Garcia, Manuel Ignacio [1 ]
Gil Cano, Anselmo [1 ]
Diaz Monrove, Juan Carlos [1 ]
机构
[1] Hosp SAS Jerez, Unidad Invest Expt, Serv Cuidados Crit & Urgencias, Jerez de la Frontera 11407, Spain
来源
CRITICAL CARE | 2009年 / 13卷 / 05期
关键词
WAVE-FORM ANALYSIS; CARDIAC-SURGERY PATIENTS; STROKE VOLUME VARIATION; RESPIRATORY VARIATIONS; BLOOD-FLOW; ESOPHAGEAL-DOPPLER; PULSE PRESSURE; OUTPUT; THERMODILUTION; FLOTRAC(TM);
D O I
10.1186/cc8027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. Methods We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >= 15% after VE. The respiratory variation in Vpeak(brach) (Delta Vpeak(brach)) was calculated as the difference between maximum and minimum values of Vpeak(brach) over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (Delta PPrad) and stroke volume variation measured using the FloTrac/Vigileo system (Lambda SVVigileo), were also calculated. Results VE increased SVi by >= 15% in 19 patients ( responders). At baseline, Delta Vpeak(brach), Delta PPrad and Delta SVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P 0.0001, respectively]. A Delta Vpeak(brach) value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A Delta PPrad value >10% and a Delta SVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. Conclusions Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
    Ji Yeon Lee
    Ji Young Kim
    Chang Hyu Choi
    Hong Soon Kim
    Kyung Cheon Lee
    Hyun Jeong Kwak
    Pediatric Cardiology, 2014, 35 : 289 - 294
  • [32] Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis
    Si, Xiang
    Xu, Hailin
    Liu, Zimeng
    Wu, Jianfeng
    Cao, Daiyin
    Chen, Juan
    Chen, Minying
    Liu, Yongjun
    Guan, Xiangdong
    ANESTHESIA AND ANALGESIA, 2018, 127 (05): : 1157 - 1164
  • [33] Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice
    Zhao, Feng
    Wang, Peng
    Pei, Shujun
    Mi, Weidong
    Fu, Qiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (11): : 20751 - 20759
  • [34] Evaluation of pulse pressure variation and pleth variability index to predict fluid responsiveness in mechanically ventilated isoflurane-anesthetized dogs
    Sano, Hiroki
    Seo, Joonbum
    Wightman, Paul
    Cave, Nick J.
    Gieseg, Mike A.
    Johnson, Craig B.
    Chambers, Paul
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (04) : 301 - 309
  • [35] Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients
    Hong, Jin-Quan
    He, He-Fan
    Chen, Zhi-Yuan
    Du, Zhen-Shuang
    Liu, Wei-Feng
    Weng, Pei-Qing
    Huang, Hao-Bo
    SAUDI MEDICAL JOURNAL, 2014, 35 (03) : 261 - 268
  • [36] Respiratory Variation in Carotid Artery Peak Systolic Velocity Is Unable to Predict Fluid Responsiveness in Spontaneously Breathing Critically Ill Patients When Assessed by Novice Physician Sonologists
    Abbasi, Adeel
    Nayeemuddin, Mohammed
    Azab, Nader
    Schick, Alexandra
    Lopardo, Thomas
    Phillips, Gary S.
    Merchant, Roland C.
    Levy, Mitchell M.
    Blaivas, Michael
    Corl, Keith A.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2021, 36 (08) : 885 - 892
  • [37] Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients
    Soliman, Randa Aly
    Samir, Shereif
    el Naggar, Ayman
    El Dehely, Khalaf
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 3 (01): : 9 - 16
  • [38] Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
    Qian Ma
    Jingjing Ji
    Xueduo Shi
    Ziyun Lu
    Lu Xu
    Jing Hao
    Wei Zhu
    Bingbing Li
    BMC Anesthesiology, 22
  • [39] Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
    Ma, Qian
    Ji, Jingjing
    Shi, Xueduo
    Lu, Ziyun
    Xu, Lu
    Hao, Jing
    Zhu, Wei
    Li, Bingbing
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [40] Variation of Left Ventricular Outflow Tract Velocity Time Integral at Different Positive End-Expiratory Pressure Levels Can Predict Fluid Responsiveness in Mechanically Ventilated Critically Ill Patients
    Zhou, Gaosheng
    Zhang, Hongmin
    Wang, Xiaoting
    Liu, Dawei
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (08) : 3101 - 3108