Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients

被引:49
|
作者
Monge Garcia, Manuel Ignacio [1 ]
Gil Cano, Anselmo [1 ]
Diaz Monrove, Juan Carlos [1 ]
机构
[1] Hosp SAS Jerez, Unidad Invest Expt, Serv Cuidados Crit & Urgencias, Jerez de la Frontera 11407, Spain
来源
CRITICAL CARE | 2009年 / 13卷 / 05期
关键词
WAVE-FORM ANALYSIS; CARDIAC-SURGERY PATIENTS; STROKE VOLUME VARIATION; RESPIRATORY VARIATIONS; BLOOD-FLOW; ESOPHAGEAL-DOPPLER; PULSE PRESSURE; OUTPUT; THERMODILUTION; FLOTRAC(TM);
D O I
10.1186/cc8027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. Methods We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >= 15% after VE. The respiratory variation in Vpeak(brach) (Delta Vpeak(brach)) was calculated as the difference between maximum and minimum values of Vpeak(brach) over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (Delta PPrad) and stroke volume variation measured using the FloTrac/Vigileo system (Lambda SVVigileo), were also calculated. Results VE increased SVi by >= 15% in 19 patients ( responders). At baseline, Delta Vpeak(brach), Delta PPrad and Delta SVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P 0.0001, respectively]. A Delta Vpeak(brach) value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A Delta PPrad value >10% and a Delta SVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. Conclusions Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] BRACHIAL ARTERY PEAK VELOCITY VARIATION TO PREDICT FLUID RESPONSIVENESS IN MECHANICALLY VENTILATED PATIENTS
    Monge Garcia, M. I.
    Gil Cano, A.
    Diaz Monrove, J. C.
    INTENSIVE CARE MEDICINE, 2009, 35 : 154 - 154
  • [2] Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients
    Manuel Ignacio Monge García
    Anselmo Gil Cano
    Juan Carlos Díaz Monrové
    Critical Care, 13
  • [3] Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease
    Song, Y.
    Kwak, Y. L.
    Song, J. W.
    Kiml, Y. J.
    Shim, J. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (01) : 61 - 66
  • [4] Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
    Yao, Bo
    Liu, Jian-yu
    Sun, Yun-bo
    BMC ANESTHESIOLOGY, 2018, 18
  • [5] Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
    Bo Yao
    Jian-yu Liu
    Yun-bo Sun
    BMC Anesthesiology, 18
  • [6] Carotid vs. aortic velocity time integral and peak velocity to predict fluid responsiveness in mechanically ventilated patients. A comparative study
    Pace, Rocco
    Lassola, Sergio
    Miori, Sara
    Cammarota, Gianmaria
    Barbariol, Federico
    Vetrugno, Luigi
    MINERVA ANESTESIOLOGICA, 2022, 88 (05) : 352 - 360
  • [7] Respiratory variation in aortic blood flow peak velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis
    Desgranges, Francois-Pierrick
    Desebbe, Olivier
    de Souza Neto, Edmundo Pereira
    Raphael, Darren
    Chassard, Dominique
    PEDIATRIC ANESTHESIA, 2016, 26 (01) : 37 - 47
  • [8] Respiratory variation in aortic blood peak velocity and caudal vena cava diameter can predict fluid responsiveness in anaesthetised and mechanically ventilated dogs
    Bucci, M.
    Rabozzi, R.
    Guglielmini, C.
    Franci, P.
    VETERINARY JOURNAL, 2017, 227 : 30 - 35
  • [9] Respirophasic Carotid Peak Systolic Velocity Variation as a Predictor of Volume Responsiveness in Mechanically Ventilated Patients with Septic Shock
    Saber, Hamdy M.
    El Maraghil, Sameh K.
    Naguib, Mina Kh.
    Abd-Elbaset, Ahmed S.
    Elkholy, Mohamed B.
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 9 (02): : 35 - 39
  • [10] The Accuracy of Velocity-Time Integral Variation and Peak Velocity Variation of the Left Ventricular Outflow Tract in Predicting Fluid Responsiveness in Postoperative Patients Mechanically Ventilated at Low Tidal Volumes
    Xie, Jin
    Wan, Jingjie
    Xu, Li
    Zhang, Yukun
    Chen, Jun
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (06) : 911 - 918