Assessment of myocardial viability and left ventricular function in patients supported by a left ventricular assist device

被引:23
|
作者
Gupta, Deepak K. [1 ]
Skali, Hicham [1 ]
Rivero, Jose [1 ]
Campbell, Patricia [2 ]
Griffin, Leslie [1 ]
Smith, Colleen [1 ]
Foster, Courtney [3 ]
Claggett, Brian [1 ]
Glynn, Robert J. [4 ]
Couper, Gregory [1 ]
Givertz, Michael M. [1 ]
Mehra, Mandeep R. [1 ]
Di Carli, Marcelo [1 ,3 ]
Solomon, Scott D. [1 ]
Pfeffer, Marc A. [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Div Cardiovasc,Dept Med, Boston, MA 02115 USA
[2] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
[3] Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[4] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Biostat, Boston, MA 02115 USA
来源
关键词
left ventricular assist device; reverse remodeling; hemodynamic unloading; single photon emission computed tomography; speckle tracking echocardiography; MECHANICAL CIRCULATORY SUPPORT; HEART-FAILURE; INFARCT SIZE; RECOVERY; ECHOCARDIOGRAPHY; RECOMMENDATIONS; IMPLANTATION; IMPROVEMENT; COMMITTEE; PERFUSION;
D O I
10.1016/j.healun.2014.01.866
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Chronically supported left ventricular assist device (LVAD) patients may be candidates for novel therapies aimed at promoting reverse remodeling and myocardial recovery. However, the effect of hemodynamic unloading with a LVAD on myocardial viability and LV function in chronically supported LVAD patients has not been fully characterized. We aimed to develop a non-invasive imaging protocol to serially quantify native cardiac structure, function, and myocardial viability while at unloading; reduced LVAD support. METHODS: Clinically stable (n = 18) ambulatory patients (83% men, median age, 61 years) supported by a HeartMate II (Thoratec, Pleasanton, CA) LVAD (median durations of heart failure 4.6 years and LVAD support 7 months) were evaluated by echocardiography and technetium-99m (Tc-99m)-sestamibi single photon emission computed tomography (SPECT) imaging at baseline and after an interval of 2 to 3 months. Echocardiographic measures of LV size and function, including speckle tracking derived circumferential strain, were compared between ambulatory and reduced LVAD support at baseline and between baseline and follow-up at reduced LVAD support. The extent of myocardial viability by SPECT was compared between baseline and follow-up at reduced LVAD support. RESULTS: With reduction in LVAD speeds (6,600 rpm; interquartile range: 6,200, 7,400 rpm), LV size increased, LV systolic function remained stable, and filling pressures nominally worsened. After a median 2.1 months, cardiac structure, function, and the extent of viable myocardium, globally and regionally, was unchanged on repeat imaging while at reduced LVAD speed. CONCLUSIONS: In clinically stable chronically supported LVAD patients, intrinsic cardiac structure, function, and myocardial viability did not significantly change over the pre-specified time frame. Echocardiographic circumferential strain and Tc-99m-sestamibi SPECT myocardial viability imaging may provide useful non-invasive end points for the assessment of cardiac structure and function, particularly for phase II studies of novel therapies aimed at promoting reverse remodeling and myocardial recovery in LVAD patients. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:372 / 381
页数:10
相关论文
共 50 条
  • [41] Left Ventricular Assist Device Implantation in Heart Failure Patients With a Left Ventricular Thrombus
    Engin, C.
    Yagdi, T.
    Balcioglu, O.
    Erkul, S.
    Baysal, B.
    Oguz, E.
    Ayik, F.
    Ozturk, P.
    Ozbaran, M.
    [J]. TRANSPLANTATION PROCEEDINGS, 2013, 45 (03) : 1017 - 1019
  • [42] The effect of left ventricular assist device therapy on myocardial fibrosis and hemodynamic function
    Travis, AR
    Zhou, Z
    Kang, YJ
    Koenig, SC
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (02) : S385 - S385
  • [43] Cognitive function and left ventricular assist device implantation
    Bhat, Geetha
    Yost, Gardner
    Mahoney, Edward
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (11): : 1398 - 1405
  • [44] Echocardiographic evaluation of left ventricular assist device function
    Song, A
    Paulsen, W
    Akosah, KO
    Tolman, DE
    Guerraty, AL
    Mohanty, PK
    [J]. CIRCULATION, 1997, 96 (08) : 2083 - 2083
  • [45] Sexual Function After Left Ventricular Assist Device
    Eckman, Peter M.
    Dhungel, Vinayak
    Mandras, Stacy
    Brisco, Meredith A.
    Emani, Sitaramesh
    Duval, Sue
    Lindenfeld, JoAnn
    Sulemanjee, Nasir
    Sokos, George G.
    Feldman, Jamie
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (19) : 2021 - 2022
  • [46] NUTRITIONAL ASSESSMENT OF PATIENTS UNDERGOING LEFT VENTRICULAR ASSIST DEVICE IMPLANTATION
    Felpel, Kevin
    Palmese, Lidia
    Shapero, Mary
    Esbenshade, Jaclyn
    Urrutia, Luis
    Hamid, Syed
    Vest, Michael
    [J]. CRITICAL CARE MEDICINE, 2020, 48
  • [47] Pulse wave analysis in the assessment of patients with left ventricular assist device
    Vlachopoulos, C
    Mcdonald, P
    Spratt, P
    O'Rourke, M
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2001, 20 (01): : 98 - 102
  • [48] Impact of COVID-19 on Patients Supported with a Left Ventricular Assist Device
    Zakrzewski, Jack
    Coyle, Laura
    Aicher, Tracy
    Chickerillo, Krystina
    Gallagher, Colleen
    Kuper, Katelyn
    Sciamanna, Chris
    Chau, Vinh Q.
    Tatooles, Antone
    [J]. ASAIO JOURNAL, 2021, 67 (11) : 1189 - 1195
  • [49] Exercise physiology, testing, and training in patients supported by a left ventricular assist device
    Loyaga-Rendon, Renzo Y.
    Plaisance, Eric P.
    Arena, Ross
    Shah, Keyur
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (08): : 1005 - 1016
  • [50] The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients
    Cowger, Jennifer
    Pagani, Francis D.
    Haft, Jonathan W.
    Romano, Matthew A.
    Aaronson, Keith D.
    Kolias, Theodore J.
    [J]. CIRCULATION-HEART FAILURE, 2010, 3 (06) : 668 - 674