Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis

被引:36
|
作者
Cantoni, Valeria [1 ]
Green, Roberta [1 ]
Acampa, Wanda [1 ,2 ]
Zampella, Emilia [1 ]
Assante, Roberta [1 ]
Nappi, Carmela [1 ]
Gaudieri, Valeria [1 ]
Mannarino, Teresa [1 ]
Cuocolo, Renato [1 ]
Di Vaia, Eugenio [1 ]
Petretta, Mario [3 ]
Cuocolo, Alberto [1 ]
机构
[1] Univ Federico II, Dept Adv Biomed Sci, Via Pansini 5, I-80131 Naples, Italy
[2] Natl Council Res, Inst Biostruct & Bioimaging, Naples, Italy
[3] Univ Federico II, Dept Translat Med Sci, Naples, Italy
关键词
CAD; SPECT; MPI; diagnostic application; meta-analysis; CONTRAST ECHOCARDIOGRAPHY; GAMMA-CAMERA; HIGH-SPEED; COMBINED SUPINE; FLOW RESERVE; SPECT MPI; ACCURACY; PROTOCOL; FEASIBILITY; MULTICENTER;
D O I
10.1007/s12350-019-01747-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We performed a meta-analysis to compare the diagnostic performance of conventional SPECT (C-SPECT) and cadmium-zinc-telluride (CZT)-SPECT systems in detecting angiographically proven coronary artery disease (CAD). Methods Studies published between January 2000 and February 2018 were identified by database search. We included studies assessing C-SPECT or CZT-SPECT as a diagnostic test to evaluate patients for the presence of CAD, defined as at least 50% diameter stenosis on invasive coronary angiography. A study was eligible regardless of whether patients were referred for suspected or known CAD. Results We identified 40 eligible articles (25 C-SPECT and 15 CZT-SPECT studies) including 7334 patients (4997 in C-SPECT and 2337 in CZT-SPECT studies). The pooled sensitivity and specificity were 85% and 66% for C-SPECT and 89% and 69% for CZT-SPECT imaging studies. The area under the curve was slightly higher for CZT-SPECT (0.89) compared to C-SPECT (0.83); accordingly, the summary diagnostic OR was 17 for CZT-SPECT and 11 for C-SPECT. The accuracy of the two tests slightly differs between C-SPECT and CZT-SPECT (chi-square 11.28, P < .05). At meta-regression analysis, no significant association between both sensitivity and specificity and demographical and clinical variables considered was found for C-SPECT and CZT-SPECT studies. Conclusions C-SPECT and CZT-SPECT have good diagnostic performance in detecting angiographic proven CAD, with a slightly higher accuracy for CZT-SPECT. This result supports the use of the novel gamma cameras in clinical routine practices also considering the improvements in acquisition time and radiation exposure reduction.
引用
收藏
页码:698 / 715
页数:18
相关论文
共 50 条
  • [1] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis
    Valeria Cantoni
    Roberta Green
    Wanda Acampa
    Emilia Zampella
    Roberta Assante
    Carmela Nappi
    Valeria Gaudieri
    Teresa Mannarino
    Renato Cuocolo
    Eugenio Di Vaia
    Mario Petretta
    Alberto Cuocolo
    [J]. Journal of Nuclear Cardiology, 2021, 28 : 698 - 715
  • [2] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single photon emission computed tomography in detecting coronary artery disease: a meta-analysis
    Green, R.
    Cantoni, V.
    Mannarino, T.
    Genova, A.
    Assante, R.
    Gaudieri, V.
    Nappi, C.
    Zampella, E.
    Buongiorno, P.
    Petretta, M.
    Acampa, W.
    Cuocolo, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S36 - S37
  • [3] Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis
    Jaarsma, Caroline
    Leiner, Tim
    Bekkers, Sebastiaan C.
    Crijns, Harry J.
    Wildberger, Joachim E.
    Nagel, Eike
    Nelemans, Patricia J.
    Schalla, Simon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (19) : 1719 - 1728
  • [4] Detection of coronary artery disease in women with use of stress single-photon emission computed tomography myocardial perfusion imaging
    Iskandrian, AE
    Heo, J
    Nallamothu, N
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (04) : 329 - 335
  • [5] Detection of coronary artery disease in women with use of stress single-photon emission computed tomography myocardial perfusion imaging
    Ami E. Iskandrian
    Jaekyeong Heo
    Nasaraiah Nallamothu
    [J]. Journal of Nuclear Cardiology, 1997, 4 : 329 - 335
  • [6] Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction
    Plachcinska, Anna
    Wlodarczyk, Michal
    Kovacevic-Kusmierek, Katarzyna
    Bienkiewicz, Malgorzata
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Kasprzak, Jaroslaw D.
    Peruga, Jan Z.
    Kusmierek, Jacek
    [J]. KARDIOLOGIA POLSKA, 2016, 74 (01) : 32 - 39
  • [7] Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography
    Randazzo, Michael
    Elias, Pierre
    Poterucha, Timothy
    Sharir, Tali
    Fish, Matthews
    Ruddy, Terrence
    Kaufmann, Philipp
    Sinusas, Albert
    Miller, Edward
    Bateman, Timothy
    Dorbala, Sharmila
    Di Carli, Marcelo
    Castillo, Michelle
    Liang, Joanna
    Miller, Robert
    Dey, Damini
    Berman, Daniel
    Slomka, Piotr
    Einstein, Andrew
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (07) : 996 - 1006
  • [8] COMPARATIVE ACCURACY OF POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: A META-ANALYSIS
    Parker, Matthew W.
    Iskandar, Aline
    Limone, Brendan
    Perugini, Andrew
    Calamari, Brian
    Jones, Charles
    Kim, Hyejin
    Coleman, Craig
    Heller, Gary
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1319 - E1319
  • [9] Sequential single-photon emission computed tomography myocardial perfusion imaging
    Shaw, LJ
    Berman, DS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (8A): : 28J - 39J
  • [10] Accuracy of Computed Tomographic Angiography and Single-Photon Emission Computed Tomography-Acquired Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease
    Arbab-Zadeh, Armin
    Di Carli, Marcelo F.
    Cerci, Rodrigo
    George, Richard T.
    Chen, Marcus Y.
    Dewey, Marc
    Niinuma, Hiroyuki
    Vavere, Andrea L.
    Betoko, Aisha
    Plotkin, Michail
    Cox, Christopher
    Clouse, Melvin E.
    Arai, Andrew E.
    Rochitte, Carlos E.
    Lima, Joao A. C.
    Brinker, Jeffrey
    Miller, Julie M.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (10)