Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography

被引:0
|
作者
Randazzo, Michael [1 ]
Elias, Pierre [2 ]
Poterucha, Timothy [2 ]
Sharir, Tali [3 ]
Fish, Matthews [4 ]
Ruddy, Terrence [5 ]
Kaufmann, Philipp [6 ]
Sinusas, Albert [7 ]
Miller, Edward [7 ]
Bateman, Timothy [8 ]
Dorbala, Sharmila [9 ]
Di Carli, Marcelo [9 ]
Castillo, Michelle [2 ]
Liang, Joanna [10 ]
Miller, Robert [10 ,11 ]
Dey, Damini [10 ]
Berman, Daniel [10 ]
Slomka, Piotr [10 ]
Einstein, Andrew [2 ,12 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Sect Cardiol, Chicago, IL USA
[2] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Med,Seymour Paul & Gloria Milstein Div Cardio, 622 West 168th St,PH 10-203, New York, NY 10032 USA
[3] Assuta Med Ctr, Dept Nucl Cardiol, Tel Aviv, Israel
[4] Oregon Heart & Vasc Inst, Sacred Heart Med Ctr, Springfield, OR USA
[5] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[6] Univ Hosp Zurich, Dept Nucl Med, Cardiac Imaging, Zurich, Switzerland
[7] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT USA
[8] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[9] Brigham & Womens Hosp, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[10] Cedars Sinai Med Ctr, Dept Imaging Med & Biomed Sci, Los Angeles, CA USA
[11] Univ Calgary, Libin Cardiovasc Inst, Dept Cardiac Sci, Calgary, AB, Canada
[12] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Radiol, 622 West 168th St,PH 10-203, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
SPECT MPI; left ventricular size; diagnostic performance; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; ISCHEMIC-HEART-DISEASE; RISK STRATIFICATION; NUCLEAR CARDIOLOGY; EJECTION FRACTION; SPECT; ACCURACY; WOMEN; ECHOCARDIOGRAPHY;
D O I
10.1093/ehjci/jeae055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Variation in diagnostic performance of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD) and its interaction with age and sex. Methods and results A total of 2066 patients without known CAD (67% male, 64.7 +/- 11.2 years) across nine institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated the performance of quantitative and visual assessments according to cardiac size [end-diastolic volume (EDV); <20th vs. >= 20th population or sex-specific percentiles], age (<75 vs. >= 75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared with those without (AUC: population 0.72 vs. 0.78, P = 0.03; sex-specific 0.72 vs. 0.79, P = 0.01) and elderly patients compared with younger patients (AUC 0.72 vs. 0.78, P = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, P = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold: EDV 0.69 vs. 0.79, P = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex. Conclusion Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.
引用
收藏
页码:996 / 1006
页数:11
相关论文
共 50 条
  • [1] Sequential single-photon emission computed tomography myocardial perfusion imaging
    Shaw, LJ
    Berman, DS
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (8A): : 28J - 39J
  • [2] Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
    Wu, MC
    Gao, DW
    Sievers, RE
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 576 - 582
  • [3] Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    Bateman, TM
    Cullom, SJ
    SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) : 37 - 51
  • [4] Single-photon emission computed tomography myocardial perfusion imaging in patients with diabetes
    Noble G.L.
    Heller G.V.
    Current Cardiology Reports, 2005, 7 (2) : 117 - 123
  • [5] Cardiac Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Finally Up to Speed?
    Wackers, Frans J. Th.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (18) : 1975 - 1978
  • [6] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [7] Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction
    Plachcinska, Anna
    Wlodarczyk, Michal
    Kovacevic-Kusmierek, Katarzyna
    Bienkiewicz, Malgorzata
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Kasprzak, Jaroslaw D.
    Peruga, Jan Z.
    Kusmierek, Jacek
    KARDIOLOGIA POLSKA, 2016, 74 (01) : 32 - 39
  • [8] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Takayuki Shibutani
    Koichi Okuda
    Hajime Ichikawa
    Toyohiro Kato
    Kenta Miwa
    Hiroyuki Tsushima
    Masahisa Onoguchi
    Akio Nagaki
    Japanese Journal of Radiology, 2020, 38 : 274 - 282
  • [9] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Shibutani, Takayuki
    Okuda, Koichi
    Ichikawa, Hajime
    Kato, Toyohiro
    Miwa, Kenta
    Tsushima, Hiroyuki
    Onoguchi, Masahisa
    Nagaki, Akio
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (03) : 274 - 282
  • [10] Procedure guidelines for radionuclide myocardial perfusion imaging with single-photon emission computed tomography
    Arumugam, Parthiban
    Harbinson, Mark
    Reyes, Eliana
    Sabharwal, Nikhant
    Tonge, Christine
    Underwood, Richard
    Kelion, Andrew
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (08) : 813 - 826