Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography

被引:0
|
作者
Randazzo, Michael [1 ]
Elias, Pierre [2 ]
Poterucha, Timothy [2 ]
Sharir, Tali [3 ]
Fish, Matthews [4 ]
Ruddy, Terrence [5 ]
Kaufmann, Philipp [6 ]
Sinusas, Albert [7 ]
Miller, Edward [7 ]
Bateman, Timothy [8 ]
Dorbala, Sharmila [9 ]
Di Carli, Marcelo [9 ]
Castillo, Michelle [2 ]
Liang, Joanna [10 ]
Miller, Robert [10 ,11 ]
Dey, Damini [10 ]
Berman, Daniel [10 ]
Slomka, Piotr [10 ]
Einstein, Andrew [2 ,12 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Sect Cardiol, Chicago, IL USA
[2] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Med,Seymour Paul & Gloria Milstein Div Cardio, 622 West 168th St,PH 10-203, New York, NY 10032 USA
[3] Assuta Med Ctr, Dept Nucl Cardiol, Tel Aviv, Israel
[4] Oregon Heart & Vasc Inst, Sacred Heart Med Ctr, Springfield, OR USA
[5] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[6] Univ Hosp Zurich, Dept Nucl Med, Cardiac Imaging, Zurich, Switzerland
[7] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT USA
[8] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[9] Brigham & Womens Hosp, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[10] Cedars Sinai Med Ctr, Dept Imaging Med & Biomed Sci, Los Angeles, CA USA
[11] Univ Calgary, Libin Cardiovasc Inst, Dept Cardiac Sci, Calgary, AB, Canada
[12] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Radiol, 622 West 168th St,PH 10-203, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
SPECT MPI; left ventricular size; diagnostic performance; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; ISCHEMIC-HEART-DISEASE; RISK STRATIFICATION; NUCLEAR CARDIOLOGY; EJECTION FRACTION; SPECT; ACCURACY; WOMEN; ECHOCARDIOGRAPHY;
D O I
10.1093/ehjci/jeae055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Variation in diagnostic performance of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD) and its interaction with age and sex. Methods and results A total of 2066 patients without known CAD (67% male, 64.7 +/- 11.2 years) across nine institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated the performance of quantitative and visual assessments according to cardiac size [end-diastolic volume (EDV); <20th vs. >= 20th population or sex-specific percentiles], age (<75 vs. >= 75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared with those without (AUC: population 0.72 vs. 0.78, P = 0.03; sex-specific 0.72 vs. 0.79, P = 0.01) and elderly patients compared with younger patients (AUC 0.72 vs. 0.78, P = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, P = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold: EDV 0.69 vs. 0.79, P = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex. Conclusion Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.
引用
收藏
页码:996 / 1006
页数:11
相关论文
共 50 条
  • [11] Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Imaging with Multifocal Collimator
    Takahashi, K.
    Takeuchi, T.
    Hosokai, Y.
    Odagiri, H.
    Usui, A.
    Saito, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S659 - S659
  • [12] Myocardial perfusion with single-photon emission computed tomography, multidetector computed tomography, or neither?
    Paolo Raggi
    G. B. John Mancini
    Journal of Nuclear Cardiology, 2017, 24 : 1722 - 1724
  • [13] Myocardial perfusion with single-photon emission computed tomography, multidetector computed tomography, or neither?
    Raggi, Paolo
    Mancini, G. B. John
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) : 1722 - 1724
  • [14] Impact of age, sex, and cardiac size on the diagnostic performance of myocardial perfusion single-photon emission computed tomography: insights from the REFINE SPECT registry
    Randazzo, M. J.
    Elias, P.
    Poterucha, T. J.
    Sharir, T.
    Fish, M. B.
    Ruddy, T. D.
    Kaufmann, P. A.
    Sinusas, A. J.
    Miller, E. J.
    Bateman, T.
    Dorbala, S.
    Di Carli, M.
    Berman, D. S.
    Slomka, P. J.
    Einstein, A. J.
    EUROPEAN HEART JOURNAL, 2021, 42 : 254 - 254
  • [15] Impact of Appropriate Use on the Prognostic Value of Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Doukky, Rami
    Hayes, Kathleen
    Frogge, Nathan
    Balakrishnan, Gautam
    Dontaraju, Venkata Satish
    Rangel, Maria O.
    Golzar, Yasmeen
    Garcia-Sayan, Enrique
    Hendel, Robert C.
    CIRCULATION, 2013, 128 (15) : 1634 - 1643
  • [16] Comparison of myocardial perfusion imaging between ultrafast and standard single-photon emission computed tomography
    Tanaka, H.
    Chikamori, T.
    Hida, S.
    Igarashi, Y.
    Shiba, C.
    Hatano, T.
    Usui, Y.
    Yamashina, A.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1025 - 1025
  • [18] Fusion imaging between myocardial perfusion single photon emission computed tomography and cardiac computed tomography
    Nakaura, T
    Utsunomiya, D
    Shiraishi, S
    Tomiguchi, S
    Kawanaka, K
    Honda, T
    Awai, K
    Yamashita, Y
    CIRCULATION, 2005, 112 (03) : E47 - E48
  • [19] Prognostic Implications of Myocardial Perfusion Single-Photon Emission Computed Tomography in the Elderly
    Hachamovitch, Rory
    Kang, Xingping
    Amanullah, Aman M.
    Abidov, Aiden
    Hayes, Sean W.
    Friedman, John D.
    Cohen, Ishac
    Thomson, Louise E. J.
    Germano, Guido
    Berman, Daniel S.
    CIRCULATION, 2009, 120 (22) : 2197 - 2206
  • [20] Diagnostic advantage of stress computed tomography myocardial perfusion over single-photon emission computed tomography for the assessment of myocardial ischemia
    Ueki, Yasushi
    Izawa, Atsushi
    Kashiwagi, Daisuke
    Nishiyama, Shigeki
    Aso, Shinichi
    Suzuki, Chihiro
    Sakurai, Shumpei
    Oguchi, Kazuhiro
    Yazaki, Yoshikazu
    Ikeda, Uichi
    Kuwahara, Koichiro
    JOURNAL OF CARDIOLOGY, 2017, 70 (1-2) : 147 - 154