The measurement of the 87Rb ground-state hyperfine splitting in an atomic fountain

被引:0
|
作者
Bize, S [1 ]
Sortais, Y [1 ]
Santos, MS [1 ]
Mandache, C [1 ]
Clairon, A [1 ]
Salomon, C [1 ]
机构
[1] Inst Natl Fiz Laser Plasmei Radiat, Bucharest, Magurele, Romania
关键词
time and frequency; optical cooling; trapping; fine and hyperfine structure; atomic fountain;
D O I
10.1117/12.378740
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The new atomic Rb-Cs fountain should confirm the recent theoretical calculations relating to the collisions of rubidium atoms. According to this theory, the displacement of the frequency of clock due to the collisional shift was predicted to be 15 times lower for Rb-87 than for Cs-133 at equal density. Using Rb instead of Cs in a fountain standard may lead to an order of magnitude improvement in frequency stability togheter with an excellent accuracy. In this paper we describe the operation of a laser cooled Rb-87 frequency standard and present a nem measurement of the Rb-87 ground state hyperfine frequency with a relative accuracy of 2.4 10(-15) by comparison with a Cs fountain atomic standard In order to measure this, first we determined the absolute frequency of the reference H-maser by comparison with the LPTF's Cs fountain. Second, we corrected the measured frequency to take into account different systematic shifts: magnetic field, black body, microwave leakage, collisions. The measured frequency is 6 834 682 610.903 333 (17) Hz This value differs from previously published values(1,2) by about 2-3 Hz and is 10(4) times more accurate.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 50 条
  • [31] Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
    Simon, E
    Laurent, P
    Clairon, A
    PHYSICAL REVIEW A, 1998, 57 (01): : 436 - 439
  • [32] Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
    Physical Review A. Atomic, Molecular, and Optical Physics, 1998, 57 (01):
  • [33] Ground-state hyperfine splitting for Rb, Cs, Fr, Ba+, and Ra+
    Ginges, J. S. M.
    Volotka, A. V.
    Fritzsche, S.
    PHYSICAL REVIEW A, 2017, 96 (06)
  • [34] Measurement of positronium thermalization in isobutane gas for precision measurement of ground-state hyperfine splitting
    Ishida, A.
    Namba, T.
    Asai, S.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2016, 49 (06)
  • [35] Development and Preliminary Operation of 87Rb Continuously Running Atomic Fountain Clock at NTSC
    Zhang, Hui
    Ruan, Jun
    Liu, Dandan
    Yang, Fan
    Fan, Sichen
    Bai, Yang
    Guan, Yong
    Wang, Xinliang
    Shi, Junru
    Zhang, Shougang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [36] A cold 87Rb atomic beam
    王晓佳
    冯焱颖
    薛洪波
    周兆英
    张文栋
    Chinese Physics B, 2011, 20 (12) : 326 - 331
  • [37] High-Precision Measurement of the Ground-State Hyperfine Splitting of 113Cd+ Ions for an Atomic Clock
    Zhang, J. W.
    Wang, S. G.
    Miao, K.
    Wang, Z. B.
    Xue, Hongbo
    Feng, Yanying
    Wang, L. J.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [38] A cold 87Rb atomic beam
    Wang Xiao-Jia
    Feng Yan-Ying
    Xue Hong-Bo
    Zhou Zhao-Ying
    Zhang Wen-Dong
    CHINESE PHYSICS B, 2011, 20 (12)
  • [39] HYPERFINE SEPARATION OF GROUND-STATE ATOMIC HYDROGEN
    CRAMPTON, SB
    RAMSEY, NF
    KLEPPNER, D
    PHYSICAL REVIEW LETTERS, 1963, 11 (07) : 338 - &
  • [40] THE GROUND-STATE HYPERFINE SPLITTING BI80+
    SHABAEVA, MB
    OPTIKA I SPEKTROSKOPIYA, 1993, 74 (06): : 1042 - 1045