A comparison of proximal femoral locking compression plates with dynamic hip screws in extracapsular femoral fractures

被引:29
|
作者
Zhong, B. [1 ]
Zhang, Y. [2 ]
Zhang, C. [1 ]
Luo, C. -F. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Peoples Hosp 6, Dept Orthopaed, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tongren Hosp, Dept Orthopaed, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Proximal femoral locking compression plate; Dynamic hip screw; Extracapsular femoral fracture; SUBTROCHANTERIC FRACTURES; PERTROCHANTERIC FRACTURES; FIXATION; LCP; FAILURE;
D O I
10.1016/j.otsr.2014.06.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The potential value of proximal femoral locking compression plate (PFLCP) for extracapsular femoral fractures has been discussed in several case reports; however, clinical control studies are lacking. Therefore, we performed a case control study to assess: (1) If PFLCP offers better functional results and fewer complications than dynamic hip screws (DHS)? (2) Which kind of extracapsular femoral fractures would benefit from PFLCP fixation? Hypothesis: The PFLCP fixation offers better functional results and fewer complications than the DHS for the treatment of extracapsular fractures. Patients and methods: A total of 83 patients with extracapsular femoral fractures were recruited. Forty-one patients underwent PFLCP fixation, and 42 patients underwent DHS fixation. Patient information, operative time, blood loss, functional level (as assessed by Sanders' traumatic hip rating scale), bone union, and implant complications were compared for the two treatment groups. Results: Patients with stable intertrochanteric fractures who underwent PFLCP fixation demonstrated shorter bone union time than the DHS fixation group (3.3 +/- 0.2 vs. 4.3 +/- 0.1 month; P<0.0001); however, both groups had 100% bone union and good to excellent scores on Sanders' traumatic hip rating scale (P=1.000). Patients with unstable intertrochanteric fractures who underwent PFLCP fixation experienced greater blood loss (619.0 +/- 23.9 vs. 474.1 +/- 19.8 ml; P<0.0001), which was mainly due to the need for open reduction (64.3% vs. 12.5%; P=0.003),compared to the DHS fixation group. No differences were identified with respect to bony union, functional level, or complications. Patients with subtrochanteric fractures who underwent PFLCP fixation demonstrated significantly shorter operative times (82.1 +/- 4.3 vs. 102.2 +/- 2.2 minutes; P < 0.0001), less blood loss (751.8 +/- 25.4 vs. 987.6 +/- 32.0 ml; P<0.0001), shorter bone union times (5.2 +/- 0.4 vs. 8.8 +/- 1.0 month; P=0.006), more good to excellent Sanders' traumatic hip rating scale scores (92.9% vs. 55.5%; P= 0.009), and fewer complications (14.2% vs. 66.6%; P=0.005) than the DHS fixation group. Conclusion: PFLCP fixation offers better functional outcomes and fewer complications for subtrochanteric femoral fractures but not for intertrochanteric femoral fractures. Levels of evidence: Case control study, level III. (C) 2014 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:663 / 668
页数:6
相关论文
共 50 条
  • [41] Comparison of ender nails, dynamic hip screws, and gamma nails in the treatment of peritrochanteric femoral fractures
    Habernek, H
    Wallner, T
    Aschauer, E
    Schmid, L
    ORTHOPEDICS, 2000, 23 (02) : 121 - 127
  • [42] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [43] Application of the Locking Compression Pediatric Hip Plate™ in children with proximal femoral tumors
    Xin Jiang
    Journal of Orthopaedic Surgery and Research, 17
  • [44] A Comparison of Proximal Femoral Nail Antirotation and Dynamic Hip Screw Devices in Trochanteric Fractures
    Zou, J.
    Xu, Y.
    Yang, H.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (04) : 1057 - 1064
  • [45] Application of the Locking Compression Pediatric Hip Plate™ in children with proximal femoral tumors
    Jiang, Xin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [46] Locking compression plate fixation of femoral intertrochanteric fractures in patients with preexisting proximal femoral deformity: a retrospective study
    Fan, Shan
    Yin, Mingming
    Xu, Yibo
    Ren, Cheng
    Ma, Teng
    Lu, Yao
    Li, Ming
    Li, Zhong
    Zhang, Kun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [47] Locking compression plate fixation of femoral intertrochanteric fractures in patients with preexisting proximal femoral deformity: a retrospective study
    Shan Fan
    Mingming Yin
    Yibo Xu
    Cheng Ren
    Teng Ma
    Yao Lu
    Ming Li
    Zhong Li
    Kun Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [48] A comparison of reversed locking compression-distal femoral plates and blade plates in osteotomies for young adult hip pathology
    MacLean, Simon B. M.
    Evans, Scott
    O'Hara, John N.
    HIP INTERNATIONAL, 2013, 23 (06) : 565 - 569
  • [49] Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables
    Graham, Simon M.
    Mak, Jonathan H.
    Moazen, Mehran
    Leonidou, Andreas
    Jones, Alison C.
    Wilcox, Ruth K.
    Tsiridis, Eleftherios
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (05) : 875 - 880
  • [50] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137