Single cytosine-based electrochemical biosensor for low-cost detection of silver ions

被引:34
|
作者
Kim, Joon Hyub [1 ]
Kim, Ki Beom [1 ]
Park, Jin Sung [1 ]
Min, Namki [1 ]
机构
[1] Korea Univ, Dept Electromech Syst Engn, Sejong 30019, Chungnam, South Korea
基金
新加坡国家研究基金会;
关键词
Ag detection; Single-cytosine; Electrochemistry; PLASMA-MASS SPECTROMETRY; SELECTIVE DETECTION; DNA; BIOCONJUGATION; SEPARATION; CYSTEINE; PROBE; AG+;
D O I
10.1016/j.snb.2017.01.181
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of Ag+ detection system with high sensitivity, selectivity and quantitatively accurate analysis is crucial because of the potential risk of Ag ion increasingly applied in various fields. As synthetic oligodeoxyribonucleotides are available to use, there have been few studies reported in the literature regarding techniques for electrochemical biosensors based on cytosine-enriched DNA used as the capture material of Ag ion. The high price and complex process for connecting NH2-terminal to DNA make it expensive to fabricate the Ag detecting system. In this study, we investigated the Ag ion detection system with single-cytosine (SC) used in the place of DNA with a functional group. The proposed system can guarantee the effect of span increase, price reduction of detection system, and lower detection limit due to the increase of immobilization efficiency by using SC as a capture probe. Three-electrode system was microfabricated on a glass wafer. SC was immobilized on the working electrode surface, and then this electrode was exposed to a solution with Ag ions and other SC for mismatching cytosine-Ag+-cytosine. Before detecting Ag ion, cyclic voltammetry and energy-dispersive X-ray spectroscopy were used for the identification of stable immobilization of SC on the surface of the functionalized Au electrode. The electrochemical analysis for increasing Ag ion concentration and the Ag+ selectivity of the SC probe were performed by square wave voltammetry. The resulted current increase is linear with the logarithmic concentration of Ag ion from 0.5 nM to 1 mM with similar to 20 pM of detection limit. The slope of in a target concentration range mentioned above are 9.14 x 10(-2) per concentration decade with R-2 value of 0.9814. The reason why our system has a lower detection limit than the previous studies is because the bound each single Ag ion performs a path role for electron transfer. Moreover, the proposed electrochemical assay has good selectivity to other environmentally relevant metal ions. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 50 条
  • [21] Low picomolar, instrument-free visual detection of mercury and silver ions using low-cost programmable nanoprobes
    Rana, Muhit
    Balcioglu, Mustafa
    Robertson, Neil M.
    Hizir, Mustafa Salih
    Yumak, Sumeyra
    Yigit, Mehmet V.
    [J]. CHEMICAL SCIENCE, 2017, 8 (02) : 1200 - 1208
  • [22] Low picomolar, instrument-free visual detection of mercury and silver ions using low-cost programmable nanoprobes
    Rana M.
    Balcioglu M.
    Robertson N.M.
    Hizir M.S.
    Yumak S.
    Yigit M.V.
    [J]. Chemical Science, 2017, 8 (02): : 1200 - 1208
  • [23] MoS2 Quantum Dots-based Low-cost and Disposable Electrochemical Sensor for the Detection of Lead (II) Ions
    Kancharla, Kantharao
    Tadi, Kiran Kumar
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (12)
  • [24] Low-cost, disposable colourimetric sensors for metal ions detection
    Alberti, Giancarla
    Zanoni, Camilla
    Magnaghi, Lisa Rita
    Biesuz, Raffaela
    [J]. JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01)
  • [25] Low-cost, disposable colourimetric sensors for metal ions detection
    Giancarla Alberti
    Camilla Zanoni
    Lisa Rita Magnaghi
    Raffaela Biesuz
    [J]. Journal of Analytical Science and Technology, 11
  • [26] Fecal Malodor Detection Using Low-Cost Electrochemical Sensors
    Kawadiya, Siddharth
    Welling, Claire
    Grego, Sonia
    Deshusses, Marc A.
    [J]. SENSORS, 2020, 20 (10)
  • [27] A Novel Fluorescent Biosensor for Detection of Silver Ions Based on Upconversion Nanoparticles
    Long, Qian
    Wen, Yanqing
    Li, Haitao
    Zhang, Youyu
    Yao, Shouzhuo
    [J]. JOURNAL OF FLUORESCENCE, 2017, 27 (01) : 205 - 211
  • [28] A Novel Fluorescent Biosensor for Detection of Silver Ions Based on Upconversion Nanoparticles
    Qian Long
    Yanqing Wen
    Haitao Li
    Youyu Zhang
    Shouzhuo Yao
    [J]. Journal of Fluorescence, 2017, 27 : 205 - 211
  • [29] Low-cost electrochemical biosensor based on a multi-walled carbon nanotube-doped molecularly imprinted polymer for uric acid detection
    Yulianti, Elly Septia
    Rahman, Siti Fauziyah
    Rizkinia, Mia
    Zakiyuddin, Ahmad
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2024, 17 (04)
  • [30] A paper-based chemiresistive biosensor employing single-walled carbon nanotubes for low-cost, point-of-care detection
    Shen, Yu
    Thien-Toan Tran
    Modha, Sidharth
    Tsutsui, Hideaki
    Mulchandani, Ashok
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 130 : 367 - 373