CsI film has been one of the most extensively used scintillators for indirect X-ray imaging because of its needle-like micro-structure. The purpose of this paper is to investigate the imaging performance of CsI screen as a function of thickness and radiation quality. Four multilayer scintillation screens with microcolumnar CsI:Tl film (thicknesses of 50 mu m, 100 mu m, 200 mu m and 300 mu m) included were prepared and coupled to an optical imaging sensor. The modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of these screens were evaluated based on the standard IEC 62220-1, and the results indicated that, in the medium spatial frequency range (1-6 lp/mm), the MTF of CsI screens with the same thickness was lower when the incident X-ray photon energy was higher, possibly owing to scattering and K-fluorescence re-absorption effects. The NNPS in the higher spatial frequency range (above 8 lp/mm) is dominated by stochastic noise while the entrance surface air Kerma (ESAK) decreases. For 100 mu m, 200 mu m and 300 mu m thick CsI screens, the DQE under RQA7 and RQA9 is lower than that under RQA3 and RQA5 due to low absorption efficiency.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Portal imaging with a CsI(Tl) transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Lovhoiden, G
    Weinberg, B
    Sawant, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 175 - 186
  • [22] X-ray imaging with submicrometer resolution employing transparent luminescent screens
    Koch, Andreas
    Raven, Carsten
    Spanne, Per
    Snigirev, Anatoly
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1998, 15 (07):
  • [23] X-ray imaging with submicrometer resolution employing transparent luminescent screens
    Koch, A
    Raven, C
    Spanne, P
    Snigirev, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (07): : 1940 - 1951
  • [24] Digital X-ray imaging using matrix detectors and composite screens
    Voronkin, E.F., 1600, Scientific and Technological Corporation (21):
  • [25] Effect of Intensifying Screens on the Sensitivity and Resolution of X-Ray Imaging Systems
    Golovkova S.I.
    Rüdiger J.
    Biomedical Engineering, 2016, 50 (02) : 105 - 109
  • [26] Performance Evaluation of a Combined Neutron and X-ray Digital Imaging System
    Sinha, V.
    Srivastava, A.
    Lee, H. K.
    Liu, X.
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2013, 2013, 8694
  • [27] Performance assessment of Cs I(T1) screens on various substrates for X-ray imaging
    冯召东
    蒋鹏
    张红凯
    赵博震
    秦秀波
    魏存峰
    刘宇
    魏龙
    Chinese Physics C, 2015, (07) : 102 - 106
  • [28] Performance assessment of Cs I(T1) screens on various substrates for X-ray imaging
    冯召东
    蒋鹏
    张红凯
    赵博震
    秦秀波
    魏存峰
    刘宇
    魏龙
    Chinese Physics C, 2015, 39 (07) : 102 - 106
  • [29] Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging
    Hui Chen
    Mu Gu
    Xiaolin Liu
    Juannan Zhang
    Bo Liu
    Shiming Huang
    Chen Ni
    Scientific Reports, 8
  • [30] Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging
    Chen, Hui
    Gu, Mu
    Liu, Xiaolin
    Zhang, Juannan
    Liu, Bo
    Huang, Shiming
    Ni, Chen
    SCIENTIFIC REPORTS, 2018, 8