Investigating the structure and biocompatibility of niobium and titanium oxides as coatings for orthopedic metallic implants

被引:67
|
作者
Pradhan, D. [1 ]
Wren, A. W. [1 ]
Misture, S. T. [1 ]
Mellott, N. P. [1 ]
机构
[1] Alfred Univ, Inamori Sch Engn, Alfred, NY 14803 USA
关键词
Coatings; Ceramics; Biocompatibility; SIMULATED BODY-FLUID; APATITE FORMATION; THIN-FILMS; PHOTOCATALYTIC ACTIVITY; OSTEOBLAST ADHESION; ANATASE; RAMAN; ALLOY; ELECTROCHROMISM; SPECTROSCOPY;
D O I
10.1016/j.msec.2015.09.059
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Applying sol gel based coatings to orthopedic metallic implant materials can significantly improve their properties and lifespan in vivo. For this work, niobium (Nb2O5) and titanium (TiO2) oxides were prepared via solution processing in order to determine the effect of atomic arrangement (amorphous/crystalline) on bioactivity. Thermal evaluation on the synthesized materials identified an endotherm for Nb2O5 at 75 degrees C with 40% weight loss below 400 degrees C, and minimal weight loss between 400 and 850 degrees C. Regarding TiO2 an endotherm was present at 92 degrees C with 25% weight loss below 400 degrees C, and 4% between 400 and 850 degrees C. Phase evolution was determined using High Temperature X-ray Diffraction (HT-XRD) where amorphous-Nb2O5 (450 degrees C), hexagonal-Nb2O5 (525 degrees C), orthorhombic-Nb2O5 (650 degrees C), amorphous-TiO2 (275 degrees C) and tetragonal TiO2 (500 degrees C) structures were produced. Simulated body fluid (SBF) testing was conducted over 1,7 and 30 days and resulted in positive chemical and morphological changes for crystalline Nb2O5 (525 degrees C) and TiO2 (500 degrees C) after 30 days of incubation. Rod-like CaP deposits were observed on the surfaces using Scanning Electron Microscopy (FE-SEM) and Grazing Incidence-X-ray Diffraction (GI-XRD) shows that the deposits were X-ray amorphous. Cell viability was higher with the TiO2 (122%) samples when compared to the growing cell population while Nb2O5 samples exhibited a range of viability (64-105%), partially dependent on materials atomic structure. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:918 / 926
页数:9
相关论文
共 46 条
  • [31] Carboxymethyl Dextran-Based Nanomicelle Coatings on Microarc Oxidized Titanium Surface for Percutaneous Implants: Drug Release, Antibacterial Properties, and Biocompatibility
    Ye, Weiliang
    Zhou, Minghao
    Zhang, Luxuan
    Yu, Jingwei
    Fan, Junjun
    Wei, Hongbo
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [32] Graphene oxide/ε-poly-L-lysine self-assembled functionalized coatings improve the biocompatibility and antibacterial properties of titanium implants
    You, Xiaoxiao
    Wang, Zhongke
    Wang, Li
    Liu, Youbo
    Chen, Hongmei
    Lan, Xiaorong
    Guo, Ling
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [33] Effects of Dicationic Imidazolium-Based Ionic Liquid Coatings on Oral Osseointegration of Titanium Implants: A Biocompatibility Study in Multiple Rat Demographics
    Wheelis, Sutton E.
    Biguetti, Claudia C.
    Natarajan, Shruti
    Chandrashekar, Bhuvana Lakkasetter
    Arteaga, Alexandra
    El Allami, Jihad
    Garlet, Gustavo P.
    Rodrigues, Danieli C.
    GENES, 2022, 13 (04)
  • [34] Structure and properties of the wollastonite-calcium phosphate coatings deposited on titanium and titanium-niobium alloy using microarc oxidation method
    Sedelnikova, M. B.
    Sharkeev, Yu. P.
    Komarova, E. G.
    Khlusov, I. A.
    Chebodaeva, V. V.
    SURFACE & COATINGS TECHNOLOGY, 2016, 307 : 1274 - 1283
  • [35] In situ preparation of nano cone-like structures of rutile titanium oxides on titanium implants by one-step femtosecond laser irradiation for enhanced mechanical properties and biocompatibility
    Hu, Yazhou
    Zou, Xianrui
    Liu, Ning
    Yang, Tai
    Xia, Chaoqun
    Wang, Hongshui
    Liang, Chunyong
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 27 : 2684 - 2694
  • [36] Structure and mechanical properties of three-dimensional capillary-porous titanium coatings on intraosteal implants
    Kalita V.I.
    Komlev D.I.
    Radyuk A.A.
    Inorganic Materials: Applied Research, 2016, 7 (04) : 536 - 541
  • [37] Microstructural investigation of porous titanium coatings, produced by thermal spraying techniques, using plasma atomization and hydride-dehydride powders, for orthopedic implants
    Gkomoza, P.
    Lampropoulos, G. S.
    Vardavoulias, M.
    Pantelis, D. I.
    Karakizis, P. N.
    Sarafoglou, Ch.
    SURFACE & COATINGS TECHNOLOGY, 2019, 357 : 947 - 956
  • [38] A bi-phase core-shell structure of Mg-based bulk metallic glass for application in orthopedic fixation implants
    Song, Sin-Mao
    Wong, Pei-Chun
    Chiang, Chih-Wei
    Tsai, Pei-Hua
    Jang, J. S. C.
    Chen, Chih-Hwa
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 111 (111):
  • [39] Influence of Nb content on the structure, morphology, nanostructure, and properties of titanium-niobium magnetron sputter deposited coatings for biomedical applications
    Gonzalez, E. D.
    Afonso, Conrado R. M.
    Nascente, Pedro A. P.
    SURFACE & COATINGS TECHNOLOGY, 2017, 326 : 424 - 428
  • [40] Comparative investigations of structure and properties of micro-arc wollastonite-calcium phosphate coatings on titanium and zirconium-niobium alloy
    Sedelnikova, M. B.
    Komarova, E. G.
    Sharkeev, Yu. P.
    Tolkacheva, T. V.
    Khlusov, I. A.
    Litvinova, L. S.
    Yurova, K. A.
    Shupletsova, V. V.
    BIOACTIVE MATERIALS, 2017, 2 (03) : 177 - 184