Biomagnetic field detection using very high sensitivity magnetoimpedance sensors for medical applications

被引:64
|
作者
Uchiyama, Tsuyoshi [1 ]
Nakayama, Shinsuke [2 ]
Mohri, Kaneo [3 ]
Bushida, Kenichi [4 ]
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Elect Engn & Comp Sci, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Cell Physiol, Nagoya, Aichi 4668550, Japan
[3] Nagoya Univ, Aichi Micro Intelligent Co, Tokai, Ibaraki 4768666, Japan
[4] Unitika Co Ltd, Tokyo 103022, Japan
关键词
INTERFERENCE DEVICE MICROSCOPE; AMORPHOUS WIRE;
D O I
10.1002/pssa.200881251
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper demonstrates the performance of magnetoimpedance (MI) sensors for biomagnetic field recording. The rms noise of an amorphous wire MI sensor with 600 turns of pick-up coil was estimated as approximately 3 pT/Hz(1/2) at 1 Hz. Here, we demonstrate that this sensitivity is enough to clearly detect magnetic cardiogram signals. We also measured the biomagnetic field around a smooth muscle tissue sample taken from a guinea-pig. We discovered that the magnetic-field waveform of a small tissue sample is similar to the voltage waveform measured by a microelectrode array in a smooth muscle sheet sample. The results suggest that the localized biomagnetic field generated by smooth muscle cells can be detected by an MI sensor. We concluded that the MI sensor is a promising device for use as a noninvasive tool to test cell activity or function through magnetic-field measurement. (C) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
引用
收藏
页码:639 / 643
页数:5
相关论文
共 50 条
  • [31] High sensitivity field emission based sensors using carbon nanotubes on silicon tip for high frequency vibration sensing
    Abdi, Yaser
    Malekan, Azadeh
    Darbari, Sara
    SOLID-STATE ELECTRONICS, 2013, 82 : 6 - 10
  • [32] Analysis of viscosity sensitivity for liquid property detection applications based on SAW sensors
    Chen, Xi
    Liu, Dali
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (08): : 1175 - 1182
  • [33] Planar Hall Effect Ring Sensors for High Field-Sensitivity
    Sinha, Brajalal
    Oh, Sunjong
    Ramulu, Torati Sri
    Lim, Jaein
    Kim, Dong-Young
    Kim, CheolGi
    EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 1136 - +
  • [34] High sensitivity trace gas monitoring for medical and environmental applications using semiconductor diode laser
    Corsi, C
    Gabrysch, M
    Modùgno, G
    Pavone, FS
    Inguscio, M
    SECOND GR-I INTERNATIONAL CONFERENCE ON NEW LASER TECHNOLOGIES AND APPLICATIONS, 1998, 3423 : 218 - 223
  • [35] Designing a very high output resistance current source for medical applications
    Hayatleh, K.
    Terzopoulos, N.
    Hart, B. L.
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2012, 99 (12) : 1739 - 1752
  • [36] New high sensitivity silicon photodetectors for medical imaging applications
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Vilkelis, G
    Verbitskaya, VEE
    Strokan, N
    Il'yashenko, I
    Ivanov, A
    Sidorov, A
    Egorov, N
    Golubkov, S
    Kon'kov, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 1225 - 1228
  • [37] New high sensitivity silicon photodetectors for medical imaging applications
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Vilkells, G
    Eremin, V
    Verbitskaya, E
    Strokan, N
    Il'yashenko, I
    Ivanov, A
    Sidorov, A
    Egorov, N
    Golubkov, S
    Kon'kov, K
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 4 - 8
  • [38] Flexible Resistive Pressure Sensors with High Sensitivity and Wide Detection Range
    Yu, Huiyang
    Wang, Zhentao
    Li, Chuanliang
    Ye, Xin
    Wu, Zhe
    Chen, Zefang
    Tu, Jiacheng
    Pan, Yifei
    Ren, Qingying
    Huang, Jianqiu
    Li, Yifeng
    2022 IEEE SENSORS, 2022,
  • [39] Wearable pressure sensors for muscle movement detection with high sensitivity and accuracy
    Yin, Yongchao
    Xing, Ling
    Hu, Zhiwei
    2024 3RD INTERNATIONAL CONFERENCE ON ROBOTICS, ARTIFICIAL INTELLIGENCE AND INTELLIGENT CONTROL, RAIIC 2024, 2024, : 144 - 149
  • [40] Folded architecture very high resolution detection systems for fiber optic sensors
    Spillman, WB
    14TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2000, 4185 : 544 - 547