4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters

被引:7
|
作者
Sothmann, Thilo [1 ]
Gauer, Tobias [2 ]
Werner, Rene [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiooncol, Hamburg, Germany
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
STEREOTACTIC BODY RADIOTHERAPY; RADIATION-THERAPY; DOSIMETRIC IMPACT; MOTION; DELIVERY; SBRT; BEAMS;
D O I
10.1371/journal.pone.0172810
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail-which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm gamma-evaluation, with the measured dose distributions serving as ground truth. Overall gamma-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% +/- 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high gamma-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that-in the sense of 4D QA of VMAT treatment plans-allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
    Chung, Hyekyun
    Jung, Jinhong
    Jeong, Chiyoung
    Kwak, Jungwon
    Park, Jin-hong
    Kim, Su Ssan
    Yoon, Sang Min
    Song, Si Yeol
    Kim, Jong Hoon
    Choi, Eun Kyung
    Cho, Seungryong
    Cho, Byungchul
    [J]. PLOS ONE, 2018, 13 (09):
  • [2] Inverse planning for four-dimensional (4D) volumetric modulated arc therapy
    Ma, Yunzhi
    Chang, Daniel
    Keall, Paul
    Xie, Yiaoqin
    Park, Jae-yoon
    Suh, Tae-Suk
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5627 - 5633
  • [3] Investigation of 4D dose in volumetric modulated arc therapy-based stereotactic body radiation therapy: does fractional dose or number of arcs matter?
    Shintani, Takashi
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Miyabe, Yuki
    Mukumoto, Nobutaka
    Mitsuyoshi, Takamasa
    Iizuka, Yusuke
    Mizowaki, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2020, 61 (02) : 325 - 334
  • [4] Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy
    Masi, Laura
    Doro, Raffaela
    Favuzza, Virginia
    Cipressi, Samantha
    Livi, Lorenzo
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [5] Volumetric modulated arc therapy quality assurance: Characterisation and evaluation of Octavius 4D system
    Lafond, C.
    Irazola, L.
    Manens, J. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S150 - S150
  • [6] AN ANALYSIS OF ACCURACY OF DOSE USING THE COMPSS PROGRAM IN VOLUMETRIC MODULATED ARC THERAPY
    Huh, H. D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S507 - S507
  • [7] A Formulation of 4D Treatment Planning for Tumour Tracking Volumetric Modulated Arc Therapy for Lung Cancer
    Cheung, Michael L. M.
    Lee, Louis K. Y.
    Chan, Anthony T. C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3645 - 3645
  • [8] Detailed evaluation of Mobius3D dose calculation accuracy for volumetric-modulated arc therapy
    Kim, Jihun
    Han, Min Cheol
    Lee, Eungman
    Park, Kwangwoo
    Chang, Kyung Hwan
    Kim, Dong Wook
    Kim, Jin Sung
    Hong, Chae-Seon
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 125 - 132
  • [9] Clinical implementation of 4D dynamic Arc therapy
    Yang, Y
    Scheibmann, E
    Li, T
    Xing, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S563 - S564
  • [10] Accuracy of 4D Cone Beam CT and 4D Fan Beam CT for Thoracic Radiation Therapy Simulation and Verification Imaging
    Nyflot, M.
    Bowen, S. R.
    Lee, T.
    Meyer, J.
    Sandison, G. A.
    Kinahan, P. E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S640 - S640