Impedimetric aptasensor for the label-free and selective detection of Interleukin-6 for colorectal cancer screening

被引:112
|
作者
Tertis, Mihaela [1 ]
Leva, Petrica Ionut [1 ]
Bogdan, Diana [2 ]
Suciu, Maria [2 ,3 ]
Graur, Florin [4 ,5 ]
Cristea, Cecilia [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Fac Pharm, Dept Analyt Chem, 4 Louis Pasteur St, Cluj Napoca 400349, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, 67-103 Donat St, Cluj Napoca 400293, Romania
[3] Babes Bolyai Univ, Fac Biol & Geol, 5-7 Clinicilor St, Cluj Napoca 400006, Romania
[4] Iuliu Hatieganu Univ Med & Pharm Cluj Napoca, Fac Gen Med, Dept Surg, 4 Louis Pasteur St, Cluj Napoca 400349, Romania
[5] Reg Inst Gastroenterol & Hepatol Octavian Fodor C, 19-21 Croitorilor St, Cluj Napoca, Romania
来源
关键词
Biosensors; Aptamers; Nanoparticles; Interleukin-6; Label-free detection; GLASSY-CARBON ELECTRODE; GOLD-NANOPARTICLES; CIRCULATING INTERLEUKIN-6; ELECTROCHEMICAL DETECTION; NANOTUBE FOREST; RAPID DETECTION; IMMUNOASSAY; FABRICATION; BIOSENSOR; APTAMERS;
D O I
10.1016/j.bios.2019.05.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Despite the fact that cancer research has experienced important advances and remarkable improvement in the curing processes during the last decades, this disease still occupies a leading position among the causes of death worldwide. It has been demonstrated that there is an interconnection between the overexpression of interleukin-6 cytokine and the tumor growth, metastasis, and therapeutic resistance in several types of malignancies. Herein, a highly sensitive and selective aptasensor for quantitative detection of interleukin-6 was developed by using a glassy carbon electrode modified with p-aminobenzoic acid, p-aminothiophenol and gold nanoparticles. A thio-terminated aptamer specific for interleukin-6 was immobilized on the surface of the modified electrode via the formation of gold-sulfur bonds. This DNA oligonucleotide was then used as a detection probe to capture the target protein at the biosensor surface allowing label-free detection by electrochemical impedance spectroscopy. The developed aptasensor showed a good linear response from 5 pgmL(-1) to 100 ngmL(-1) with a detection limit of 1.6 pgmL(-1), within the range of physiological concentration of the protein. The biosensor exhibited high selectivity and has been successfully used to detect interleukin-6 in blood samples collected from patients suffering of colorectal cancer, with excellent recoveries after the addition of known amount of the target protein.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [41] A Label-Free Colorimetric Aptasensor for Flavokavain B Detection
    Ke, Sisi
    Wang, Ningrui
    Chen, Xingyu
    Tian, Jiangwei
    Li, Jiwei
    Yu, Boyang
    SENSORS, 2025, 25 (02)
  • [42] A simple label-free electrochemical aptasensor for dopamine detection
    Zhou, Jiawan
    Wang, Wenyang
    Yu, Peng
    Xiong, Erhu
    Zhang, Xiaohua
    Chen, Jinhua
    RSC ADVANCES, 2014, 4 (94): : 52250 - 52255
  • [43] A label-free fluorescent aptasensor for selective and sensitive detection of streptomycin in milk and blood serum
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Nameghi, Morteza Alinezhad
    Ramezani, Mohammad
    Abnous, Khalil
    FOOD CHEMISTRY, 2016, 203 : 145 - 149
  • [44] Label-free electrochemical aptasensor constructed by layer-by-layer technology for sensitive and selective detection of cancer cells
    Wang, Tianshu
    Liu, Jiyang
    Gu, Xiaoxiao
    Li, Dan
    Wang, Jin
    Wang, Erkang
    ANALYTICA CHIMICA ACTA, 2015, 882 : 32 - 37
  • [45] Label-free impedimetric immunosensor for sensitive detection of fenvalerate in tea
    Wang, Meirong
    Kang, Huimin
    Xu, Dan
    Wang, Chengyin
    Liu, Shuzhao
    Hu, Xiaoya
    FOOD CHEMISTRY, 2013, 141 (01) : 84 - 90
  • [46] Label-free impedimetric detection of glycan-lectin interactions
    La Belle, Jeffrey T.
    Gerlach, Jared Q.
    Svarovsky, Sergei
    Joshi, Lokesh
    ANALYTICAL CHEMISTRY, 2007, 79 (18) : 6959 - 6964
  • [47] Label-free selective impedimetric detection of Cu2+ ions using catalytic DNA
    Ocana, Cristina
    Malashikhina, Natalia
    del Valle, Manel
    Pavlov, Valeri
    ANALYST, 2013, 138 (07) : 1995 - 1999
  • [48] Organic Electrochemical Transistor Aptasensor for Interleukin-6 Detection
    Diacci, Chiara
    Burtscher, Bernhard
    Berto, Marcello
    Ruoko, Tero-Petri
    Lienemann, Samuel
    Greco, Pierpaolo
    Berggren, Magnus
    Borsari, Marco
    Simon, Daniel T.
    Bortolotti, Carlo A.
    Biscarini, Fabio
    ACS APPLIED MATERIALS & INTERFACES, 2023, 16 (45) : 61467 - 61474
  • [49] Label-free impedimetric aptasensor for lysozyme detection based on carbon nanotube-modified screen-printed electrodes
    Rohrbach, Falk
    Karadeniz, Hakan
    Erdem, Arzum
    Famulok, Michael
    Mayer, Guenter
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (02) : 454 - 459
  • [50] Label-free impedimetric aptasensor with antifouling surface chemistry: A prostate specific antigen case study
    Jolly, Pawan
    Formisano, Nello
    Tkac, Jan
    Kasak, Peter
    Frost, Christopher G.
    Estrela, Pedro
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 306 - 312