A NEW KNOTLESS SUTURE STAPLE DOUBLE ROW CONSTRUCT FOR MEDIAL REPAIR OF ROTATOR CUFF TEARS

被引:0
|
作者
Schlegel, Theodore F. [1 ]
Otarodifard, Karimdad Amir [1 ]
Hawkins, Richard J. [1 ]
Vangsness, Thomas, Jr. [1 ]
Bui, Christopher [1 ]
McGarry, Michelle H. [1 ]
Lee, Thay Q. [1 ]
机构
[1] Steadman Hawkins Clin, Denver, CO USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:17 / 18
页数:2
相关论文
共 50 条
  • [1] Biomechanical comparison of knotless wide suture double-row SutureBridge rotator cuff repair to double-row standard suture repair
    Liu, Victor K.
    Bouwmeester, Theresia M.
    Smith, Geoffrey C. S.
    Lam, Patrick H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) : 1621 - 1626
  • [2] Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears
    Ide, Junji
    Karasugi, Tatsuki
    Okamoto, Nobukazu
    Taniwaki, Takuya
    Oka, Kiyoshi
    Mizuta, Hiroshi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (10) : 1544 - 1554
  • [3] Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
    Greenspoon, Joshua A.
    Petri, Maximilian
    Millett, Peter J.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (01): : E127 - E132
  • [4] Rotator Cuff Repair with Knotless All-Suture Medial Row Anchors and Biceps Autograft Augmentation
    Hassebrock, Jeffrey D.
    Mccarthy, Timothy P.
    Sylvia, Stephen M.
    Stokes, Daniel J.
    Shinsako, Kevin K.
    Frank, Rachel M.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (08): : E1361 - E1367
  • [5] Arthroscopic Knotless Double-Row Rotator Cuff Repair Without Side-to-Side Suture Placement
    Giannotti, Bradley F.
    Tauro, Joseph C.
    TECHNIQUES IN ORTHOPAEDICS, 2010, 25 (03) : 165 - 166
  • [6] Effects of a lateral row anchor position on the suture holding strength of a double-row knotless fixation in rotator cuff repair
    Acan, Ahmet Emrah
    Hapa, Onur
    Horoz, Levent
    Kara, Aylin
    Havitcioglu, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2018, 29 (01): : 46 - 51
  • [7] Knotless Single-row Rotator Cuff Repair: A Comparative Biomechanical Study of 2 Knotless Suture Anchors
    Efird, Chad
    Traub, Shaun
    Baldini, Todd
    Rioux-Forker, Dana
    Spalazzi, Jeffrey P.
    Davisson, Twana
    Hawkins, Monica
    McCarty, Eric
    ORTHOPEDICS, 2013, 36 (08) : E1033 - E1037
  • [8] The Arthroscopic "Montgolfier Double-Row Knotless" Rotator Cuff Repair Technique
    Gasbarro, Gregory
    Neyton, Lionel
    ARTHROSCOPY TECHNIQUES, 2019, 8 (07): : E669 - E674
  • [9] Medial rotator cuff failure after arthroscopic double-row rotator cuff repair
    Trantalis, John N.
    Boorman, Richard S.
    Pletsch, Kristie
    Lo, Ian K. Y.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (06): : 727 - 731
  • [10] H-loop Knotless Double-Row Repair Versus Knotted Suture Bridge for Rotator Cuff Tears A Biomechanical and Histological Study in an Animal Model
    Guo, Jiang
    Long, Yi
    Zhou, Min
    He, Zhang-Hai
    Zeng, Wei-Ke
    Yu, Meng-Lei
    Yamuhanmode, Alike
    Tang, Yi-Yong
    Li, Fang-Qi
    Meng, Ke
    Hou, Jing-Yi
    Yang, Rui
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (07): : 1948 - 1959