Effects of a lateral row anchor position on the suture holding strength of a double-row knotless fixation in rotator cuff repair

被引:5
|
作者
Acan, Ahmet Emrah [1 ]
Hapa, Onur [2 ]
Horoz, Levent [2 ]
Kara, Aylin [3 ]
Havitcioglu, Hasan [2 ]
机构
[1] Mugla Sitki Kocman Univ, Training & Res Hosp, Dept Orthoped & Traumatol, Mugla, Turkey
[2] Dokuz Eylul Univ, Med Fac, Dept Orthoped & Traumatol, Izmir, Turkey
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkey
关键词
Biomechanics; double-row; rotator cuff; FAILURE; MODEL; BONE;
D O I
10.5606/ehc.2018.57519
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aims to evaluate the effects of anchor positions on the suture holding strength of a double-row knotless fixation in rotator cuff repair. Materials and methods: Four different double-row fixation techniques were assessed. In group 1, a 15-mm-wide mattress suture was fixed using a knotless lateral row anchor, horizontal to the shaft. In group 2, the medial sutures were fixed with a 5-mm more lateral anchor that was placed at 45 degrees to the long axis of the humeral shaft. In group 3, different from group 2, medial sutures were fixed with a 30-mm mattress suture width. In group 4, the mattress sutures coming from the medial row anchors were fixed to the 10-mm more lateral row, vertical to the long axis of the humeral shaft. The specimens were cyclically loaded from 10 N to 30 N at 0.5 Hz for 50 cycles, and then loaded to failure. Results: Group 4 had higher cyclic elongation values than group 1 (p=0.021) and group 3 (p=0.006). Group 1 had lower maximum load value than group 3 (p=0.011). Most of the specimens failed with suture ruptures. Unlike the other groups, none of the specimens in group 4 failed via a suture pull through the lateral anchor. Conclusion: A horizontal lateral row anchor positioned closer to the medial anchor resulted in less cyclic elongation when compared to a more vertically positioned lateral row anchor. The vertical or oblique positioning of the lateral row anchor did not result in any increase in the failure load value; however, the vertical placement prevented a suture pull through the lateral row anchor.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [1] Biomechanical comparison of knotless wide suture double-row SutureBridge rotator cuff repair to double-row standard suture repair
    Liu, Victor K.
    Bouwmeester, Theresia M.
    Smith, Geoffrey C. S.
    Lam, Patrick H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) : 1621 - 1626
  • [2] Arthroscopic single-row versus double-row suture anchor rotator cuff repair
    Mazzocca, AD
    Millett, PJ
    Guanche, CA
    Santangelo, SA
    Arciero, RA
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (12): : 1861 - 1868
  • [3] Does the Literature Support Double-Row Suture Anchor Fixation for Arthroscopic Rotator Cuff Repair? A Systematic Review Comparing Double-Row and Single-Row Suture Anchor Configuration
    Nho, Shane J.
    Slabaugh, Mark A.
    Seroyer, Shane T.
    Grumet, Robert C.
    Wilson, Joseph B.
    Verma, Nikhil N.
    Romeo, Anthony A.
    Bach, Bernard R., Jr.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (11): : 1319 - 1328
  • [4] Early pullout of lateral row knotless anchor in rotator cuff repair
    Tsiouri, Chrysi
    Mok, Daniel H.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2009, 3 (03): : 63 - 65
  • [5] Suture Loosening and Its Effect on Tendon Fixation in Knotless Double-Row Rotator Cuff Repairs
    Kummer, Frederick
    Hergan, David J.
    Thut, David C.
    Pahk, Brian
    Jazrawi, Laith M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (11): : 1478 - 1484
  • [6] Arthroscopic rotator cuff repair with double-row fixation
    Huijsmans, Pol E.
    Pritchard, Mark P.
    Berghs, Bart M.
    van Rooyen, Karin S.
    Wallace, Andrew L.
    de Beer, Joe F.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (06): : 1248 - 1257
  • [7] The Arthroscopic "Montgolfier Double-Row Knotless" Rotator Cuff Repair Technique
    Gasbarro, Gregory
    Neyton, Lionel
    ARTHROSCOPY TECHNIQUES, 2019, 8 (07): : E669 - E674
  • [8] Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model
    Mahar, Andrew
    Tamborlane, Jeffrey
    Oka, Richard
    Esch, James
    Pedowitz, Robert A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (12): : 1265 - 1270
  • [9] Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
    Kim, DH
    ElAttrachet, NS
    Tibone, JE
    Jun, BJ
    DeLaMora, SN
    Kvitnet, RS
    Lee, TQ
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (03): : 407 - 414
  • [10] Bridging suture makes consistent and secure fixation in double-row rotator cuff repair
    Fukuhara, Tetsutaro
    Mihata, Teruhisa
    Jun, Bong Jae
    Neo, Masashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (05) : 852 - 857