Implantable Cardioverter Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices: Utilization Patterns, Related Procedures, and Complications

被引:14
|
作者
Alvarez, Paulino A. [1 ,2 ]
Sperry, Brett W. [1 ,3 ]
Perez, Antonio L. [1 ]
Yaranov, Dmitry M. [1 ]
Randhawa, Varinder [1 ]
Luthman, Jacob [1 ]
Cantillon, Daniel J. [1 ]
Starling, Randall C. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Univ Iowa, Dept Cardiovasc Med, Iowa City, IA USA
[3] St Lukes Hosp Kansas City, Mid Amer Heart Inst, Kansas City, MO USA
来源
关键词
implanted cardioverter defibrillator; infection; left ventricular assist device; ARRHYTHMIAS;
D O I
10.1161/JAHA.118.011813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The effect of implantable cardioverter defibrillators (ICD) in patients with continuous flow left ventricular assist devices (LVADs) on outcomes has not been evaluated in a randomized clinical trial. Methods and Results-This is a retrospective single-center study that included patients who underwent continuous flow LVAD implantation at the Cleveland Clinic between October 2004 and March 2017. Patients were evaluated according to the presence or absence of ICD at the time of LVAD insertion. Among 486 patients in the study cohort, 387 (79.6%) had an ICD before LVAD insertion. Patients with ICD before LVAD were older and had lower use of pre-LVAD inotropes, extracorporeal membrane oxygenation, and mechanical ventilation. There were 81 patients (21.4% of patients with ICD) who required 93 procedures after LVAD: 74 generator exchanges, 12 lead revisions, and 7 complete system removals because of infection. Of the 99 patients without ICD, 52 (53%) underwent ICD implantation: 29 for primary prevention and 23 for secondary prevention. Patients were followed for a median of 401 (interquartile range 150-966) days. The presence of a pre-LVAD ICD was not associated with mortality in a multivariable model (hazard ratio 1.19, 95% CI 0.73-1.93, P=0.492), nor was the presence of an ICD at any point when analyzed as a time-varying covariate (hazard ratio 1.05, 95% CI 0.50-2.20, P=0.907). Conclusions-There is no apparent mortality benefit associated with an ICD in a contemporary cohort of patients with continuous flow LVADs to balance considerable morbidity involving ICD-related procedures and complications.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ventricular Arrhythmias in Left Ventricular Assist Device Patients With Implantable Cardioverter Defibrillators
    Stahl, Erika
    Pauwaa, Sunil
    Modi, Sejal
    Pappas, Pat
    Tatooles, Antone
    Bhat, Geetha
    JOURNAL OF CARDIAC FAILURE, 2010, 16 (08) : S54 - S54
  • [22] Implantable Cardioverter-Defibrillators in Patients With Left Ventricular Assist Devices On Trial and in Need of a Trial
    Pokorney, Sean D.
    Al-Khatib, Sana M.
    JACC-HEART FAILURE, 2017, 5 (12) : 927 - 929
  • [23] Implantable cardioverter-defibrillator-related procedures and associated complications in continuous flow left ventricular assist device recipients: A multicenter experience
    Ravichandran, Ashwin
    Pothineni, Naga Venkata K.
    Trivedi, Jaimin R.
    Roukoz, Henri
    Ahmed, Mustafa M.
    Bhan, Adarsh
    Bhat, Geetha
    Cowger, Jennifer
    Al Ahmad, Amin
    Natale, Andrea
    Di Biase, Luigi
    Slaughter, Mark S.
    Lakkireddy, Dhanunjaya
    Gopinathannair, Rakesh
    HEART RHYTHM O2, 2021, 2 (06): : 691 - 697
  • [24] Implantable Cardioverter Defibrillator Utilization and Programming among Patients with Left Ventricular Assist Devices
    Kiehl, Erich L.
    Joseph, Susan
    Agarwal, Rahul
    Nabutovsky, Yelena
    Cantillon, Daniel J.
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (08) : S21 - S22
  • [25] Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device An Analysis of the INTERMACS Registry
    Clerkin, Kevin J.
    Topkara, Veli K.
    Demmer, Ryan T.
    Dizon, Jose M.
    Yuzefpolskaya, Melana
    Fried, Justin A.
    Mai, Xingchen
    Mancini, Donna M.
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Colombo, Paolo C.
    Garan, A. Reshad
    JACC-HEART FAILURE, 2017, 5 (12) : 916 - 926
  • [26] Ventricular arrhythmias in patients supported with ventricular assist devices and the role of implantable cardioverter defibrillators
    Gkouziouta, A. Aggeliki
    Kostopoulou, A.
    Theodorakis, G.
    Sfirakis, P.
    Adamopoulos, S.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 273 - 273
  • [27] Electromagnetic interference from left ventricular assist devices in patients with subcutaneous implantable cardioverter-defibrillators
    Ishida, Yuji
    Payne, Joshua E.
    Field, Michael E.
    Gold, Michael R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (05) : 1195 - 1201
  • [28] Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review
    Lopez-Gil, Maria
    Fontenla, Adolfo
    Delgado, Juan F.
    Rodriguez-Munoz, Daniel
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2019, 3 (02)
  • [29] Electromagnetic interference from left ventricular assist devices detected in patients with implantable cardioverter-defibrillators
    Sheldon, Seth H.
    Jazayeri, Mohammad-Ali
    Pierpoline, Michael
    Mohammed, Moghniuddin
    Parikh, Valay
    Robinson, Alexander
    Noheria, Amit
    Haglund, Nicholas
    Sauer, Andrew J.
    Reddy, Y. Madhu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (01) : 93 - 101
  • [30] Occurrence of ventricular tachyarrhythmias in left ventricular assist devices patients with implantable defibrillators
    Sasov, M.
    Lesny, P.
    Svetlosak, M.
    Margitfalvi, P.
    Hatala, R.
    Goncalvesova, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 401 - 401