Wind Tunnel Test Study of Estimation Method on Peak Wind Pressure of Low-Rise Buildings

被引:2
|
作者
Duan, Min [1 ]
Wang, Jiaqi [1 ]
Wang, Xiuzhen [1 ]
Li, Pingshi [1 ]
机构
[1] Chongqing Univ, City Coll Sci & Technol, Chongqing 402167, Peoples R China
关键词
low-rise building; estimation of extreme value; wind tunnel test; EQUIVALENT STATIC DESIGN; TECH FIELD EXPERIMENTS; WORKING APPROACH; LOADS;
D O I
10.4028/www.scientific.net/AMM.488-489.813
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In response to the estimation of the peak values of wind pressure on the maintenance structure, the results with TTU low-rise building standard model of different methods are analyzed and compared. The results show: the results of peak-to-average method and Cook & Mayne method are very close for the long sample estimation of the peak values of wind pressure, the former is the most ideal method for estimation of extreme wind pressure; For short sample estimation, the peak-to-average method fails because the sampling is not long enough, but the Cook & Mayne method can estimate accurate peak value of wind pressure by the short sample (the corresponding prototype time not less than 600s); The peak factor method based on the assumption of normal distribution is not applicable to low-rise building and the results are relatively dangerous.
引用
收藏
页码:813 / 816
页数:4
相关论文
共 50 条