Analysis of the Ballistocardiographic Artifact Removal in Simultaneous EEG-fMRI Recording Using Independent Component Analysis and Coherence Function

被引:0
|
作者
Silva de Souza, Ana Claudia [1 ]
Rodrigues, Gustavo Fernandes [1 ]
Callan, Daniel [2 ]
Yehia, Hani Camille [3 ]
机构
[1] Fed Univ Sao Joao del Rey, Dept Telecommun & Mechatron Engn, Ouro Branco, MG, Brazil
[2] ATR, Neural Informat Anal Lab, Kyoto, Japan
[3] Univ Fed Minas Gerais, Dept Elect Engn, Belo Horizonte, MG, Brazil
关键词
BCG artifact; independent components; coherence function; BCG ARTIFACTS; MR SCANNER; REDUCTION; SIGNALS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The simultaneous acquisition of EEG and fMRI has becoming increasingly important for neuroimaging research. However, this integration comes with artifacts that directly interfere in the signal quality. Independent component analysis has been one of the most used tools to remove biological artifacts and more recently it has been used to the removal of BCG artifact present when simultaneous EEG and fMRI is acquired. Although widely adopted some questions regarding the reliability of the estimated sources are still unanswered. The efficiency of the removal depends on the correct identification and selection of the artifact-related independent components. This selection is not obvious since different strategies give different results. Considering that no real BCG artifact-free data can be collected inside an MR scanner it is a difficult task to select the best criteria or best algorithm. In this paper we contribute to the solution of this problem proposing an automatic component selection method based on maximum absolute magnitude squared coherence function between the independent components and the ECG signal.
引用
收藏
页码:552 / 556
页数:5
相关论文
共 50 条
  • [41] Ordinal patterns in epileptic brains: Analysis of intracranial EEG and simultaneous EEG-fMRI
    C. Rummel
    E. Abela
    M. Hauf
    R. Wiest
    K. Schindler
    [J]. The European Physical Journal Special Topics, 2013, 222 : 569 - 585
  • [42] Ordinal patterns in epileptic brains: Analysis of intracranial EEG and simultaneous EEG-fMRI
    Rummel, C.
    Abela, E.
    Hauf, M.
    Wiest, R.
    Schindler, K.
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2013, 222 (02): : 569 - 585
  • [43] Using independent component analysis in simultaneous EEG/fMRI for identification and localisation of interictal slow brain activity
    Härle, M.
    Feige, B.
    Frings, L.
    Wagner, K.
    Tebartz van Elst, L.
    Schulze-Bonhage, A.
    [J]. EPILEPSIA, 2006, 47 : 152 - 152
  • [44] Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis
    Nakamura, Wakako
    Anami, Kimitaka
    Mori, Takeyuki
    Saitoh, Osamu
    Cichocki, Andrzej
    Amari, Shun-ichi
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1294 - 1308
  • [45] Removal of imaging artifacts in EEG during simultaneous EEG/fMRI recording: Reconstruction of a high-precision artifact template
    Koskinen, Miika
    Vartiainen, Nuutti
    [J]. NEUROIMAGE, 2009, 46 (01) : 160 - 167
  • [46] Automated Removal of EKG Artifact From EEG Data Using Independent Component Analysis and Continuous Wavelet Transformation
    Hamaneh, Mehdi Bagheri
    Chitravas, Numthip
    Kaiboriboon, Kitti
    Lhatoo, Samden D.
    Loparo, Kenneth A.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (06) : 1634 - 1641
  • [47] Using voxel-specific hemodynamic response function in EEG-fMRI data analysis
    Lu, Yingli
    Bagshaw, Andrew P.
    Grova, Christophe
    Kobayashi, Ellane
    Dubeau, Francois
    Gotman, Jean
    [J]. NEUROIMAGE, 2006, 32 (01) : 238 - 247
  • [48] IMAGING EPILEPTIC NETWORKS USING LOCAL CANONICAL CORRELATION ANALYSIS: A SIMULTANEOUS EEG-fMRI STUDY
    Dong, L.
    Luo, C.
    Yao, D.
    [J]. EPILEPSIA, 2013, 54 : 214 - 214
  • [49] Detection of experimental ERP effects in combined EEG-fMRI: Evaluating the benefits of interleaved acquisition and Independent Component Analysis
    Lavric, Aureliu
    Bregadze, Nino
    Benattayallah, Abdelmalek
    [J]. CLINICAL NEUROPHYSIOLOGY, 2011, 122 (02) : 267 - 277
  • [50] Removal Artifacts from EEG Signal Using Independent Component Analysis and Principal Component Analysis
    Turnip, Arjon
    Junaidi, Edy
    [J]. 2014 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY, INFORMATICS, MANAGEMENT, ENGINEERING, AND ENVIRONMENT (TIME-E 2014), 2014, : 296 - 302