Electronic neutron dosimeter in high-energy neutron fields

被引:4
|
作者
Wielunski, M. [1 ]
Brall, T. [1 ]
Dommert, M. [2 ]
Trinkl, S. [3 ]
Ruehm, W. [1 ]
Mares, V. [1 ]
机构
[1] Helmholtz Zentrum Munchen, Inst Radiat Protect, Ingolstadter Landstr 1, D-85764 Neuherberg, Germany
[2] Phys Tech Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany
[3] Fed Off Radiat Protect BFS, Ingolstadter Landstr 1, D-85764 Neuherberg, Germany
关键词
CERF; Bonner sphere spectroscopy; Neutron dosimetry; FLUKA; High-energy neutrons; CERF FACILITY; SPECTROMETER; SIMULATION; ALTITUDES;
D O I
10.1016/j.radmeas.2018.04.015
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In neutron fields including neutron energies above 20 MeV a conventional neutron dosimeter is not suitable for measurements of neutron personal dose equivalent, Hp(10), over the whole energy range. Therefore, for such fields an electronic neutron dosimeter has been developed recently at Helmholtz Zentrum Munchen (HMGU). In general, neutron dose measurements performed with this dosimeter at neutron energies below 2 MeV show an accuracy of about 30% [1]. Here we report the use of this dosimeter at the CERN-EU high-energy Reference Field (CERF) facility in Geneva, Switzerland. At this facility the available neutron fields include neutrons with energies below, but also above 20 MeV. In the present paper, personal dose equivalent (Hp(10)) values obtained with the ELectronic neutron DOsimeter (ELDO) are compared to neutron personal dose equivalent (Hp(10)) values obtained with the HMGU extended-range Bonner Sphere Spectrometer, and to reference values from FLUKA Monte Carlo simulations provided by CERF. It is shown that for continuous neutron spectra as those at CERF behind concrete shielding or secondary neutrons from cosmic rays, the dosimeter results are satisfactory for radiation protection purposes. However, in neutron fields including neutrons above about 7 MeV, where the major neutron dose contribution is from neutrons between 10 keV and several MeV (like those at CERF behind iron shielding), the doses provided by ELDO might be too small and care must be taken in interpreting the results.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [21] Neutron-Induced Electronic Failures around a High-Energy Linear Accelerator
    Kry, S.
    Johnson, J.
    White, R.
    Howell, R.
    Kudchadker, R.
    Gillin, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] Probing high-energy electronic excitations in NiO using inelastic neutron scattering
    Kim, Young-June
    Sorini, A. P.
    Stock, C.
    Perring, T. G.
    Van den Brink, J.
    Devereaux, T. P.
    PHYSICAL REVIEW B, 2011, 84 (08):
  • [23] Neutron-induced electronic failures around a high-energy linear accelerator
    Kry, Stephen F.
    Johnson, Jennifer L.
    White, R. Allen
    Howell, Rebecca M.
    Kudchadker, Rajat J.
    Gillin, Michael T.
    MEDICAL PHYSICS, 2011, 38 (01) : 34 - 39
  • [24] HIGH-ENERGY NEUTRON SPECTROMETRY WITH PLASTIC SSNTDS
    BALCAZARGARCIA, M
    DURRANI, SA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 173 (01): : 131 - 135
  • [25] DOSIMETRY STUDIES OF A HIGH-ENERGY NEUTRON BEAM
    BAARLI, J
    SULLIVAN, AH
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (02): : 269 - &
  • [26] SUMMARY OF HIGH-ENERGY NEUTRON SOURCES AND THEIR CHARACTERISTICS
    SMATHERS, JB
    ALMOND, PR
    OTTE, VA
    GRANT, WH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 3 : 149 - 154
  • [27] MICRODOSIMETRY OF A CLINICAL HIGH-ENERGY NEUTRON BEAM
    DURHAM, JS
    BLUE, TE
    WEHRING, BW
    BLUE, JW
    ROBERTS, WK
    HEALTH PHYSICS, 1984, 47 (01): : 192 - 192
  • [28] Calculated intensity of high-energy neutron beams
    Mustapha, B
    Nolen, JA
    Back, BB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 521 (01): : 247 - 253
  • [29] Superheated emulsions as high-energy neutron dosemeters
    Das, M
    Sawamura, T
    Abe, M
    Kaneko, JH
    Homma, A
    Fujita, F
    Tsuda, S
    Nishitani, T
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 325 - 331
  • [30] THE HIGH-ENERGY NEUTRON FACILITY AT CLATTERBRIDGE HOSPITAL
    BLAKE, SW
    SHAW, JE
    BONNETT, DE
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (02): : 165 - 165