Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: A phantom study

被引:37
|
作者
Schindera, S. T. [1 ,2 ]
Winklehner, A. [3 ]
Alkadhi, H. [3 ]
Goetti, R. [3 ]
Fischer, M. [3 ]
Gnannt, R. [3 ]
Szucs-Farkas, Z. [1 ]
机构
[1] Univ Bern, Univ Hosp Berne, Inst Diagnost Intervent & Pediat Radiol, Bern, Switzerland
[2] Univ Basel Hosp, Dept Radiol, CH-4031 Basel, Switzerland
[3] Univ Zurich Hosp, Dept Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
关键词
PATIENT SIZE; NOISE; ENHANCEMENT; ATTENUATION; REDUCTION; SETTINGS; 16-MDCT; ENERGY; TUMORS; PHASE;
D O I
10.1016/j.crad.2012.10.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the effect of an automatic tube voltage selection technique on image quality and radiation dose in abdominal computed tomography (CT) angiography of various body sizes. MATERIALS AND METHODS: An abdominal aortic phantom was filled with iodinated contrast medium and placed into three different cylindrical water containers, which simulated a small, intermediate-sized, and large patient. The phantom was scanned with a standard 120 kVp abdominal CT angiography protocol and with an optimized tube voltage protocol that was modulated by an automatic tube voltage technique. The attenuation of the aorta, background, and image noise was measured, and the contrast-to-noise ratio (CNR) was calculated. Three independent readers assessed the overall image quality. RESULTS: The automatic tube voltage technique selected 70 kVp as the optimal tube voltage for the small phantom, 80 kVp for the intermediate phantom, and 100 kVp for the large phantom. Compared to the standard 120 kVp protocol, the automatic tube voltage selection yielded significantly increased CNR values in the small phantom (15.8 versus 19.4, p < 0.001), intermediate phantom (8.4 versus 8.7, p < 0.05), and large phantom (4.3 versus 4.6, p < 0.01). The automatic tube voltage selection resulted in a 55%, 49%, and 39% reduction in the volume CT dose index (CTDIvol) in the small, intermediate, and large phantoms, respectively. The subjective overall image quality of the three phantom sizes at different tube voltages ranged between poor and good. CONCLUSION: Compared to a standard 120 kVp abdominal CT angiography protocol, the automatic tube voltage selection substantially reduced the radiation dose without compromising image quality in various simulated patient sizes. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E79 / E86
页数:8
相关论文
共 50 条
  • [21] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Hye Joo Park
    Seo-Youn Choi
    Ji Eun Lee
    Sanghyeok Lim
    Min Hee Lee
    Boem Ha Yi
    Jang Gyu Cha
    Ji Hye Min
    Bora Lee
    Yunsub Jung
    [J]. European Radiology, 2022, 32 : 3974 - 3984
  • [22] Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: Phantom study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Toth, Thomas L.
    Nguyen, Giao T.
    Toncheva, Greta I.
    DeLong, David M.
    Yoshizumi, Terry T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : W100 - W105
  • [23] Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol
    Park, Young Jean
    Kim, Young Jin
    Lee, Ji Won
    Kim, Hee Yeong
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Nam, Ji Eun
    Choi, Byoung Wook
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 184 - 190
  • [24] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Meinel, Felix G.
    Canstein, Christian
    Schoepf, U. Joseph
    Sedlmaier, Martin
    Schmidt, Bernhard
    Harris, Brett S.
    Flohr, Thomas G.
    De Cecco, Carlo N.
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (07) : 1643 - 1650
  • [25] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Felix G. Meinel
    Christian Canstein
    U. Joseph Schoepf
    Martin Sedlmaier
    Bernhard Schmidt
    Brett S. Harris
    Thomas G. Flohr
    Carlo N. De Cecco
    [J]. European Radiology, 2014, 24 : 1643 - 1650
  • [26] Coronary CT angiography by modifying tube voltage and contrast medium concentration: Evaluation of image quality and radiation dose
    Gazafroudi, Seyede Shokoofeh Mousavi
    Tavakkoli, Mohammad Bagher
    Moradi, Maryam
    Gazafroudi, Seyede Shabnam Mousavi
    Yadegarfar, Ghasem
    Behjati, Mohaddeseh
    Karimian, Mohammad
    Khajouei, Amirreza Sajjadieh
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (07): : 1391 - 1396
  • [27] The impact of ASiR-V on abdominal CT radiation dose and image quality-A phantom study
    Morup, Svea Deppe
    Stowe, John
    Kusk, Martin Weber
    Precht, Helle
    Foley, Shane
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (03) : 453 - 459
  • [28] Effect of Automatic Tube Voltage Selection and Reconstruction Method On CT Dose Reduction
    Kanal, K.
    Pedroza, F.
    Zamora, D.
    Moirano, J.
    Robinson, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3248 - 3248
  • [29] Effect of Tube Voltage on CT Noise Levels in Different Phantom Sizes
    Karmazyn, Boaz
    Liang, Yun
    Klahr, Paul
    Jennings, S. Gregory
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : 1001 - 1005
  • [30] Pediatric thoracic CT angiography at 70 kV: a phantom study to investigate the effects on image quality and radiation dose
    Robert D. MacDougall
    Patricia L. Kleinman
    Lifeng Yu
    Edward Y. Lee
    [J]. Pediatric Radiology, 2016, 46 : 1114 - 1119