Electrocatalysis at a thin multi-wall carbon nanotube film modified glassy carbon electrode

被引:0
|
作者
Fei, J [1 ]
Sun, Y [1 ]
Hu, S [1 ]
Gao, Z [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
carbon nanotube; voltammetry; amperometry; electrode; ascorbic acid;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A sensitive and selective amperometric procedure based on a glassy carbon electrode (GCE) modified with a thin multi-wall carbon nanotube (MWNT) film, for the determination of ascorbic acid (AA) was developed. The modified electrode showed excellent electrocatalytic activity towards the oxidation of AA. The oxidation potential of AA shifted negatively by as much as 460 mV to -18 mV (vs. SCE) at the modified electrode. Experimental variables were investigated and optimized. Amperometric tests of AA were performed at -10 mV. A linear response was obtained in the range of 5.0 10(-6) to 4.0 10(-3) M with a detection limit of 2.0 10(-6) M. Interference studies indicated that the modified electrode is highly selective to AA in a mixture of AA, uric acid and dopamine. The proposed procedure was applied to the determination of AA in pharmaceutical and food samples with little or no sample pretreatment.
引用
收藏
页码:260 / 263
页数:4
相关论文
共 50 条
  • [21] Study on electrochemical behavior of Tyrosine at multi-wall carbon nanotubes modified glassy carbon electrode
    Shao, Chen
    Wei, Yingliang
    Jiang, Ling
    [J]. JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2008, 11 (03) : 175 - 179
  • [22] Hematoxylin multi-wall carbon nanotubes modified glassy carbon electrode for electrocatalytic oxidation of hydrazine
    Zare, Hamid R.
    Nasirizadeh, Navid
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (12) : 4153 - 4160
  • [23] Differential Pulse Voltammetric Determination of Hydroxylamine at an Indenedione Derivative Electrodeposited on a Multi-Wall Carbon Nanotube Modified Glassy Carbon Electrode
    Zare, Hamid R.
    Chatraei, Fatemeh
    Nasirizadeh, Navid
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (10) : 1977 - 1985
  • [24] Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    Zare, Hamid R.
    Nasirizadeh, Navid
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02): : 666 - 672
  • [25] Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
    Tefera, M.
    Tessema, M.
    Admassie, S.
    Mehretie, S.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (02): : 139 - 150
  • [26] Voltammetric behavior and determination of phenylephrine at a glassy carbon electrode modified with multi-wall carbon nanotubes
    Zhu, Yuan-hai
    Zhang, Zhi-ling
    Zhao, Wei
    Pang, Dai-wen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 308 - 314
  • [27] Electrochemical Determination of Melamine with a Glassy Carbon Electrode Coated with a Multi-Wall Carbon Nanotube/Chitosan Composite
    Zhao, Tingkai
    Liu, Lehao
    Li, Guangming
    Dang, Alei
    Li, Tiehu
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (05) : K141 - K145
  • [28] Electrochemiluminescence Determination of Phenylbutazone Based on Modified Electrode by Multi-wall Carbon Nanotube
    Chen Yiting
    He Weiwen
    Lin Qi
    Lou Benyong
    Chen Guonan
    [J]. ACTA CHIMICA SINICA, 2009, 67 (14) : 1615 - 1620
  • [29] Electrochemical behavior and determination of isoniazid at multi-wall carbon nanotube modified electrode
    Qu, WY
    Hong, W
    Wu, KB
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (10) : 1431 - 1434
  • [30] Voltammetric Behavior and Determination of 17b-Estradiol at Multi-Wall Carbon Nanotube-Nafion Modified Glassy Carbon Electrode
    Norifumi Terui
    Bunshi Fugetsu
    Shunitz Tanaka
    [J]. Analytical Sciences, 2006, 22 : 895 - 898