Impact of a Cooled Cooling Air System on the External Aerodynamics of a Gas Turbine Combustion System

被引:11
|
作者
Walker, A. Duncan [1 ]
Koli, Bharat [1 ]
Guo, Liang [2 ]
Beecroft, Peter [3 ]
Zedda, Marco [4 ]
机构
[1] Loughborough Univ, Dept Aeronaut & Automot Engn, Loughborough LE11 3TU, Leics, England
[2] Jilin Univ, Dept Internal Combust Engines, Changchun 130022, Peoples R China
[3] Rolls Royce PLC, SIN A65, POB 31,Moor Lane, Derby DE24 8BJ, England
[4] Rolls Royce PLC, ML 92, POB 31,Moor Lane, Derby DE24 8BJ, England
基金
“创新英国”项目;
关键词
gas turbine combustion system aerodynamics; prediffuser; cooled cooling air; turbine cooling; COMPRESSOR EXIT CONDITIONS; ANNULAR DIFFUSERS; PERFORMANCE;
D O I
10.1115/1.4035228
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To manage the increasing turbine temperatures of future gas turbines a cooled cooling air system has been proposed. In such a system some of the compressor efflux is diverted for additional cooling in a heat exchanger (HX) located in the bypass duct. The cooled air must then be returned, across the main gas path, to the engine core for use in component cooling. One option is do this within the combustor module and two methods are examined in the current paper; via simple transfer pipes within the dump region or via radial struts in the prediffuser. This paper presents an experimental investigation to examine the aerodynamic impact these have on the combustion system external aerodynamics. This included the use of a fully annular, isothermal test facility incorporating a bespoke 1.5 stage axial compressor, engine representative outlet guide vanes (OGVs), prediffuser, and combustor geometry. Area traverses of a miniature five-hole probe were conducted at various locations within the combustion system providing information on both flow uniformity and total pressure loss. The results show that, compared to a datum configuration, the addition of transfer pipes had minimal aerodynamic impact in terms of flow structure, distribution, and total pressure loss. However, the inclusion of prediffuser struts had a notable impact increasing the prediffuser loss by a third and consequently the overall system loss by an unacceptable 40%. Inclusion of a hybrid prediffuser with the cooled cooling air (CCA) bleed located on the prediffuser outer wall enabled an increase of the prediffuser area ratio with the result that the system loss could be returned to that of the datum level.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The method optimization of gas turbine blades cooling system
    Galitseisky, BM
    Loburev, AV
    Cherny, MS
    [J]. HEAT TRANSFER 1998, VOL 6: GENERAL PAPERS, 1998, : 535 - 540
  • [32] EMERGENCY COOLING SYSTEM FOR A NUCLEAR POWER GAS TURBINE
    BAMMERT, K
    [J]. ATOMKERNENERGIE, 1971, 18 (02): : 131 - &
  • [33] IMPACT OF A COMBUSTOR-TURBINE INTERFACE ON TURBINE VANE AERODYNAMICS AND FILM COOLING
    Lerch, A.
    Bauer, R.
    Krueckels, J.
    Henze, M.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A, 2019,
  • [34] Modeling and Simulation Study of High Mach Gas Turbine Engine with Cooled Cooling Air Technology
    Yao, Yao
    Wang, Zhan-Xue
    Zhang, Xiao-Bo
    Gui, Feng
    [J]. Tuijin Jishu/Journal of Propulsion Technology, 2023, 44 (02):
  • [35] Optimization research of cooling gas injection angle at leading edge of air-cooled turbine
    Hong, Bo-Wen
    Wen, Feng-Bo
    Wang, Song-Tao
    Cui, Tao
    Wang, Zhong-Qi
    [J]. Tuijin Jishu/Journal of Propulsion Technology, 2014, 35 (12): : 1653 - 1660
  • [36] Impact of a Combustor-Turbine Interface on Turbine Vane Aerodynamics and Film Cooling
    Lerch, Andreas
    Bauer, Rainer
    Krueckels, Joerg
    Henze, Marc
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2020, 142 (07):
  • [37] A contribution to the abrassive effect of particles in a gas turbine pre-swirl cooling air system
    Schneider, O.
    Benra, F. -K.
    Dohmen, H. J.
    Jarzombek, K.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2005, VOL 3 PTS A AND B, 2005, : 1113 - 1120
  • [38] Augmentation of gas turbine performance using integrated EAHE and Fogging Inlet Air Cooling System
    Barakat, S.
    Ramzy, Ahmed
    Hamed, A. M.
    El-Emam, S. H.
    [J]. ENERGY, 2019, 189
  • [39] Gas turbine inlet air cooling system for enhancing propane recovery in a gas plant: Theoretical and cost analyses
    Bin Shams, Mohamed
    Elkanzi, E. M.
    Ramadhan, Zakareya
    Rahma, Sadiq
    Khamis, Mohamed
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2017, 43 : 22 - 32
  • [40] Particle Deposition Characteristics on Internal Rib Cooling Channel of Air-Cooled Turbine Blade for Marine Gas Turbine
    Zhao, Hong-Jie
    Jiang, Yu-Ting
    Du, Lei
    Fang, Yi-Bo
    Zheng, Qun