Semi-automatic Measurement of Ocular Volume from Facial Computed Tomography and Correlation with Axial Length

被引:1
|
作者
Chung, Junkyu [1 ]
Park, In Ki [2 ]
Choi, Samjin [3 ]
Shin, Jae-Ho [1 ]
机构
[1] Kyung Hee Univ, Sch Med, Kyung Hee Univ Hosp Gangdong, Dept Ophthalmol, Seoul, South Korea
[2] Kyung Hee Univ, Sch Med, Med Ctr, Dept Ophthalmol, Seoul, South Korea
[3] Kyung Hee Univ, Sch Med, Dept Bioengn, Seoul, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Axial length; Facial computed tomography; Ocular volume; Volume measurements; INTRAOCULAR-PRESSURE; BEVACIZUMAB; HYPOTONY;
D O I
10.3341/jkos.2019.60.3.210
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure the ocular volume from facial computed tomography (CT) scans using a semi-automatic computer program, and to analyze possible correlations between the axial length and ocular volume using regression analysis. Methods: Forty eyes from 20 facial CT scans were used to measure the ocular volumes. The cross-sectional ocular areas were calculated using a semi-automatic program based on MATLAB r2009a (MathWorks, Inc., Natick, MA, USA), and the ocular volumes were calculated from serial cross-sectional areas. The axial lengths were measured by A-scan ultrasound. Statistical analysis including regression analysis was used to determine possible correlations between the ocular volumes and axial lengths. Results: The mean ocular volumes measured in males and females were 7.16 +/- 1.80 cm(3) and 7.24 +/- 3.38 cm(3), respectively. The mean axial lengths measured in males and females were 23.47 +/- 0.69 mm and 23.23 +/- 1.64 mm, respectively. There were positive correlations using Pearson's correlation coefficient and the partial correlation coefficient adjusted by axial length. Using regression analysis, the following statistically significant equation was derived: (ocular volume [cm(3)] = 0.0056558 x axial length(3) [mm(3)] -0.1798106 x axial length(2) [mm(2)] + 32.9008570 [p < 0.001, R-2 = 0.384]). Conclusions: The ocular volume measurement tool in this study was noninvasive and very useful, without special equipment. Accurate estimation of ocular volumes by a statistical equation was feasible, and these findings may be helpful in further study of various ocular diseases and in predicting preoperative and postoperative ocular volumes.
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [21] Augmented reality guidance in laparoscopic hepatectomy with deformable semi-automatic computed tomography alignment (with video)
    Le Roy, B.
    Ozgur, E.
    Koo, B.
    Buc, E.
    Bartoli, A.
    [J]. JOURNAL OF VISCERAL SURGERY, 2019, 156 (03) : 261 - 262
  • [22] Semi-automatic segmentation and surface reconstruction of computed tomography images by using rotoscoping and warping techniques
    Park, S. K.
    Kim, B. K.
    Shin, D. S.
    [J]. FOLIA MORPHOLOGICA, 2020, 79 (01) : 156 - 161
  • [23] A Semi-Automatic Segmentation Method for the Structural Analysis of Carotid Atherosclerotic Plaques by Computed Tomography Angiography
    dos Santos, Florentino Luciano Caetano
    Joutsen, Atte
    Terada, Mitsugu
    Salenius, Juha
    Eskola, Hannu
    [J]. JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2014, 21 (09) : 930 - 940
  • [24] Semi-Automatic Integrated Segmentation Approaches and Contour Extraction Applied to Computed Tomography Scan Images
    Khoodoruth, B. Dhalila S. Y.
    Rughooputh, Harry C. S.
    Lefer, Wilfrid
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2008, 2008
  • [25] Quantitative Erosion Volume Measurement From Computed Tomography
    Duryea, Jeffrey W.
    Solomon, Daniel H.
    Lu, Bing
    Russell, Ruby
    Han, Roger
    Gravallese, Ellen M.
    Kay, Jonathan
    [J]. ARTHRITIS AND RHEUMATISM, 2013, 65 : S836 - S837
  • [26] A simple method for semi-automatic readjustment for positioning in post-mortem head computed tomography imaging
    Kawazoe, Yusuke
    Morishita, Junji
    Matsunobu, Yusuke
    Okumura, Miki
    Shin, Seitaro
    Usumoto, Yosuke
    Ikeda, Noriaki
    [J]. JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2019, 16 : 57 - 64
  • [27] Dual-energy computed tomography quality control: Initial experiences with a semi-automatic analysis tool
    Sauranen, S.
    Makela, T.
    Kaasalainen, T.
    Kortesniemi, M.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118
  • [28] A semi-automatic technique for measurement of arterial wall from black blood MRI
    Ladak, HM
    Thomas, JB
    Mitchell, JR
    Rutt, BK
    Steinman, DA
    [J]. MEDICAL PHYSICS, 2001, 28 (06) : 1098 - 1107
  • [29] Comparison and assessment of semi-automatic image segmentation in computed tomography scans for image-guided kidney surgery
    Glisson, Courtenay L.
    Altamar, Hernan O.
    Herrell, S. Duke
    Clark, Peter
    Galloway, Robert L.
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6265 - 6274
  • [30] Semi-automatic measurement of the airway dimension by computed tomography using the full-with-half-maximum method: a study of the measurement accuracy according to the measurement accuracy according to the orientation of an artificial airway
    Kim, Namkug
    Seo, Joon Beom
    Song, Koun-Sik
    Chae, Eun Jin
    Kang, Suk-Ho
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 236 - 242