Semi-automatic Measurement of Ocular Volume from Facial Computed Tomography and Correlation with Axial Length

被引:1
|
作者
Chung, Junkyu [1 ]
Park, In Ki [2 ]
Choi, Samjin [3 ]
Shin, Jae-Ho [1 ]
机构
[1] Kyung Hee Univ, Sch Med, Kyung Hee Univ Hosp Gangdong, Dept Ophthalmol, Seoul, South Korea
[2] Kyung Hee Univ, Sch Med, Med Ctr, Dept Ophthalmol, Seoul, South Korea
[3] Kyung Hee Univ, Sch Med, Dept Bioengn, Seoul, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Axial length; Facial computed tomography; Ocular volume; Volume measurements; INTRAOCULAR-PRESSURE; BEVACIZUMAB; HYPOTONY;
D O I
10.3341/jkos.2019.60.3.210
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure the ocular volume from facial computed tomography (CT) scans using a semi-automatic computer program, and to analyze possible correlations between the axial length and ocular volume using regression analysis. Methods: Forty eyes from 20 facial CT scans were used to measure the ocular volumes. The cross-sectional ocular areas were calculated using a semi-automatic program based on MATLAB r2009a (MathWorks, Inc., Natick, MA, USA), and the ocular volumes were calculated from serial cross-sectional areas. The axial lengths were measured by A-scan ultrasound. Statistical analysis including regression analysis was used to determine possible correlations between the ocular volumes and axial lengths. Results: The mean ocular volumes measured in males and females were 7.16 +/- 1.80 cm(3) and 7.24 +/- 3.38 cm(3), respectively. The mean axial lengths measured in males and females were 23.47 +/- 0.69 mm and 23.23 +/- 1.64 mm, respectively. There were positive correlations using Pearson's correlation coefficient and the partial correlation coefficient adjusted by axial length. Using regression analysis, the following statistically significant equation was derived: (ocular volume [cm(3)] = 0.0056558 x axial length(3) [mm(3)] -0.1798106 x axial length(2) [mm(2)] + 32.9008570 [p < 0.001, R-2 = 0.384]). Conclusions: The ocular volume measurement tool in this study was noninvasive and very useful, without special equipment. Accurate estimation of ocular volumes by a statistical equation was feasible, and these findings may be helpful in further study of various ocular diseases and in predicting preoperative and postoperative ocular volumes.
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [1] Measurement of Orbital Volume from Different Slice Thickness Facial Computed Tomography Scans Using a Semi-automatic Program
    Kim, Hye Jee
    Han, Ji Sang
    Park, In Ki
    Choi, Sam Jin
    Shin, Jae-Ho
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (11): : 1671 - 1677
  • [2] A semi-automatic method for measurement of seedling length
    Orbovic, V
    Kieu, K
    [J]. PLANT GROWTH REGULATION, 1996, 20 (03) : 303 - 305
  • [3] Semi-automatic volumetric assessment of perihemorrhagic edema with computed tomography
    Volbers, Bastian
    Staykov, Dimitre
    Wagner, Ingrid
    Doerfler, Arnd
    Saake, Marc
    Schwab, Stefan
    Bardutzky, Juergen
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2011, 18 (11) : 1323 - 1328
  • [4] A robust and semi-automatic quantitative measurement of patellofemoral instability based on four dimensional computed tomography
    Chen, Hao
    Kluijtmans, Leo
    Bakker, Max
    Dunning, Hans
    Kang, Yan
    van de Groes, Sebastiaan
    Sprengers, Andre M. J.
    Verdonschot, Nico
    [J]. MEDICAL ENGINEERING & PHYSICS, 2020, 78 (78) : 29 - 38
  • [5] Semi-automatic segmentation of subcutaneous tumours from micro-computed tomography images
    Ali, Rehan
    Gunduz-Demir, Cigdem
    Szilagyi, Tuende
    Durkee, Ben
    Graves, Edward E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 8007 - 8019
  • [6] Semi-Automatic Segmentation of Cone Beam Computed Tomography Datasets for Volume Measurements of Equine Cheek Teeth
    Herren, Fabienne L.
    Gerber, Vinzenz
    Meier, Raphael
    Schweizer-Gorgas, Daniela
    Klopfenstein Bregger, Micael D.
    [J]. JOURNAL OF VETERINARY DENTISTRY, 2022, 39 (01) : 41 - 48
  • [7] Semi-automatic magnetic resonance imaging based orbital fat volumetry: reliability and correlation with computed tomography
    Willaert, R.
    Degrieck, B.
    Orhan, K.
    Deferm, J.
    Politis, C.
    Shaheen, E.
    Jacobs, R.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (03) : 416 - 422
  • [8] Measurement of normal ocular volume by the use of computed tomography
    Igbinedion, B. O.
    Ogbeide, O. U.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 315 - 319
  • [9] Semi-Automatic Ice-Rafted Debris Quantification With Computed Tomography
    Cederstrom, Jan Magne
    Van der Bilt, Willem G. M.
    Storen, Eivind W. N.
    Rutledal, Sunniva
    [J]. PALEOCEANOGRAPHY AND PALEOCLIMATOLOGY, 2021, 36 (10)
  • [10] VASCULAR NETWORK SEMI-AUTOMATIC SEGMENTATION Using Computed Tomography Angiography
    Maule, Petr
    Polivka, Jiri
    Kleckova, Jana
    [J]. ICSOFT 2010: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON SOFTWARE AND DATA TECHNOLOGIES, VOL 1, 2010, : 323 - 326