Leaky-Least-Logarithmic-Absolute-Difference-Based Control Algorithm and Learning-Based Inc MPPT Technique for Grid-Integrated PV System

被引:77
|
作者
Kumar, Nishant [1 ]
Singh, Bhim [1 ]
Panigrahi, Bijaya Ketan [1 ]
Xu, Lie [2 ]
机构
[1] Indian Inst Technol Delhi, Dept Elect Engn, New Delhi 110016, India
[2] Univ Strathclyde, Dept Elect & Elect Engn, Glasgow G1 1XQ, Lanark, Scotland
关键词
Grid-integrated system; incremental conductance (InC); maximum power point tracking (MPPT); power quality; solar photovoltaic (PV) array; STRATEGY;
D O I
10.1109/TIE.2018.2890497
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper introduces a novel leaky least logarithmic absolute difference (LLLAD)-based control algorithm and a learning-based incremental conductance (LIC) maximum power point tracking algorithm for a grid-integrated solar photovoltaic (PV) system. Here, a three-phase topology of the grid-integrated PV system is implemented, with the nonlinear/linear loads. The proposed LIC technique is an improved form of an incremental conductance (InC) algorithm, where inherent problems of the traditional InC technique, such as steady-state oscillations, slow dynamic responses, and fixed-step-size issues, are successfully mitigated. The prime objective of the proposed LLLAD control is to meet the active power requirement of the loads from the generated solar PV power, and after satisfying the load demand, the excess power is supplied to the grid. However, when the generated solar power is less than the load demand, then LLLAD meets the load by taking extra required power from the grid. During these power management processes, on the grid side, the power quality is maintained. During daytime, the proposed control technique provides load balancing, power factor correction, and harmonic filtering. Moreover, when solar irradiation is zero, then the dc-link capacitor and a voltage-source converter act as a distribution static compensator, which enhances the utilization factor of the system. The proposed techniques are modeled, and their performances are verified experimentally on a developed prototype in solar insolation variation conditions, unbalanced loading, and in different grid disturbances such as over- and undervoltage, phase imbalance, harmonics distortion in the grid voltage, etc. Test results have met the objectives of the proposed paper, and parameters are under the permissible limit, according to the IEEE-519 standard.
引用
收藏
页码:9003 / 9012
页数:10
相关论文
共 40 条
  • [31] A Fast MPPT Algorithm for Smart Grid-PV Connected System Based on Multiple Sparse-Aware Time-Varying Stepsize Adaptation Technique
    Abdallatif, Haider
    Abdel-Qader, Ikhlas
    Harb, Ahmad
    2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,
  • [32] Power quality improvement of grid interfaced solar PV system using an improved least mean square-based unified control technique
    Mohapatra, Prerana
    Panda, Anup Kumar
    Venkata Ramana Naik, N.
    Senapati, Laxmidhar
    Behera, Sameer Kumar
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (06) : 2868 - 2888
  • [33] Adaptive terminal synergetic-backstepping technique based machine learning regression algorithm for MPPT control of PV systems under real climatic conditions
    Nguimfack-Ndongmo, Jean de Dieu
    Harrison, Ambe
    Alombah, Njimboh Henry
    Kuate-Fochie, Rene
    Asoh, Derek Ajesam
    Kenne, Godpromesse
    ISA TRANSACTIONS, 2024, 145 : 423 - 442
  • [34] Single Stage Three-Phase Grid Integrated Solar PV System with Fast Sparse NLMF Based Control Adaptive Technique
    Singh, Amresh Kumar
    Hussain, Ikhlaq
    Singh, Bhim
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [35] Integration of Solar PV With Low-Voltage Weak Grid System: Using Normalized Laplacian Kernel Adaptive Kalman Filter and Learning Based InC Algorithm
    Kumar, Nishant
    Singh, Bhim
    Panigrahi, Bijaya Ketan
    Chakraborty, Chandan
    Suryawanshi, Hiralal Murlidhar
    Verma, Vishal
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (11) : 10746 - 10758
  • [36] Priority Based Critical Load Selection Algorithm for Grid Integrated PV Powered EV Charging System with Optimal DC Link Control
    Aijaz M.
    Hussain I.
    Lone S.A.
    Distributed Generation and Alternative Energy Journal, 2023, 38 (01): : 293 - 318
  • [37] Data-driven green energy extraction: Machine learning-based MPPT control with efficient fault detection method for the hybrid PV-TEG system
    Khan, Kamran
    Rashid, Saad
    Mansoor, Majad
    Khan, Ammar
    Raza, Hasan
    Zafar, Muhammad Hamza
    Akhtar, Naureen
    ENERGY REPORTS, 2023, 9 : 3604 - 3623
  • [38] Deep Q-Network Reinforcement Learning-Based Rotor Side Control System of a Grid Integrated DFIG Wind Energy System Under Variable Wind Speed Conditions
    Behara, Ramesh Kumar
    Saha, Akshay Kumar
    IEEE ACCESS, 2024, 12 : 184179 - 184205
  • [39] Feed-forward DC-bus control loop applied to a single-phase grid-connected PV system operating with PSO-based MPPT technique and active power-line conditioning
    OLiveira da Silva, Sergio Augusto
    Sampaio, Leonardo Poltronieri
    de Oliveira, Fernando Marcos
    Durand, Fabio Renan
    IET RENEWABLE POWER GENERATION, 2017, 11 (01) : 183 - 193
  • [40] Fuzzy SVPWM-based inverter control realisation of grid integrated photovoltaic-wind system with fuzzy particle swarm optimisation maximum power point tracking algorithm for a grid-connected PV/wind power generation system: hardware implementation
    Priyadarshi, Neeraj
    Padmanaban, Sanjeevikumar
    Bhaskar, Mahajan Sagar
    Blaabjerg, Frede
    Sharma, Amarjeet
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (07) : 962 - 971