Biocompatible PEG Grafting on DLC-coated Nitinol Alloy for Vascular Stents

被引:30
|
作者
Shin, Hong-Sub [1 ,2 ]
Park, Kwideok [1 ]
Kim, Ji Heung [2 ]
Kim, Jae-Jin [1 ]
Han, Dong Keun [1 ]
Moon, Myoung-Woon [3 ]
Lee, Kwang-Ryeol [3 ]
Shin, Ji Hoon [4 ]
机构
[1] Korea Inst Sci & Technol, Biomat Res Ctr, Seoul 130650, South Korea
[2] Sungkyunkwan Univ, Dept Chem Engn, Suwon, South Korea
[3] Korea Inst Sci & Technol, Future Convergence Technol Lab, Seoul 130650, South Korea
[4] Asan Hosp, Dept Radiol, Seoul, South Korea
关键词
stent; nitinol (TiNi alloy); surface modification; diamond-like carbon (DLC); poly(ethylene glycol) (PEG); biocompatibility; ENHANCED BLOOD COMPATIBILITY; SELF-ASSEMBLED MONOLAYERS; STAINLESS-STEEL STENTS; NEGATIVE CILIA CONCEPT; POLY(ETHYLENE GLYCOL); PROTEIN ADSORPTION; BIOMEDICAL APPLICATIONS; IN-VIVO; SURFACE; PLASMA;
D O I
10.1177/0883911509104273
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The surfaces of Nitinol (TiNi), a popular metal alloy for arterial stents were thin-coated with diamond-like carbon (DLC) and then grafted with poly(ethylene glycol) (PEG) to increase biocompatibility. The TiNi control, DLC-coated TiNi (TiNi-DLC), and the PEG-grafted TiNi-DLC (TiNi-DLC-PEG) surface characteristics and biocompatibility were evaluated. The hydrophilicity of the TiNi-DLC-PEG significantly increased and the amount of both oxygen and nitrogen on the TiNi-DLC-PEG also increased compared to the TiNi control and TiNi-DLC due to the grafted PEG. The ratio between albumin and fibrinogen was higher on the PEG-grafted surface than the other surfaces when tested with human blood components; the platelet adhesion decreased the most on the TiNi-DLC-PEG surface, indicating improved blood compatibility. For in vivo tests using a rat model, the samples that were implanted for 6 weeks formed fibrous tissue; the tissue layer was much thinner on the PEG-grafted sample than the other two groups. The present results indicate that PEG-grafted TiNi-DLC surface may be effective in enhancing biocompatibility of blood-contacting biomaterials including vascular stents.
引用
收藏
页码:316 / 328
页数:13
相关论文
共 30 条
  • [21] Excellent Seizure and Friction Properties Achieved with a Combination of an a-C:H:Si DLC-Coated Journal and an Aluminum Alloy Plain Bearing
    Iwata, Takumi
    Oikawa, Masakuni
    Chida, Riki
    Ishii, Daijiro
    Ogihara, Hidemi
    Mihara, Yuji
    Kano, Makoto
    COATINGS, 2021, 11 (09)
  • [22] Influence of zirconium doping on the growth of apatite and corrosion behavior of DLC-coated titanium alloy Ti-13Nb-13Zr
    Mohan, L.
    Babu, P. Dilli
    Kumar, Prateek
    Anandan, C.
    SURFACE AND INTERFACE ANALYSIS, 2013, 45 (11-12) : 1785 - 1791
  • [23] Tribological and investigation study of a dlc-coated H13 friction drilling tool on AZ31B magnesium alloy
    Alphonse, Mathew
    Raja, V. K. Bupesh
    Cepova, Lenka
    Salunkhe, Sachin
    Nasr, Emad Abouel
    Abdelgawad, Abdelaty Edrees
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2024, 10
  • [24] Investigation of Anti-Corrosive Performance of a Si-Doped DLC-Coated Magnesium Alloy Stent Deposited by RF-Plasma CVD
    Nakatani, Tatsuyuki
    Takeuchi, Harumichi
    Wada, Akira
    Yamashita, Shuzo
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2019, 32 (03) : 511 - 517
  • [25] A completely new biocompatible metal alloy for construction of stents with minimal MR interference: Initial tests versus nitinol, tantalum and stainless steel
    Van Dijk, LC
    Van dijk, BF
    Van Holten, J
    Matheijssen, NA
    Pattynama, PM
    RADIOLOGY, 1999, 213P : 366 - 366
  • [26] Tribocorrosion behavior of DLC-coated Ti-6Al-4V alloy deposited by PIID and PEMS plus PIID techniques for biomedical applications
    Hatem, Andre
    Lin, Jianliang
    Wei, Rougha
    Torres, Ricardo D.
    Laurindo, Carlos
    Soares, Paulo
    SURFACE & COATINGS TECHNOLOGY, 2017, 332 : 223 - 232
  • [27] A cytotoxicity and wear analysis of trapeziometacarpal total joint replacement implant consisting of DLC-coated Co-Cr-Mo alloy with the use of titanium gradient interlayer
    Kopova, Ivana
    Kronek, Jakub
    Bacakova, Lucie
    Fencl, Jaroslav
    DIAMOND AND RELATED MATERIALS, 2019, 97
  • [28] MICROSTRUCTURE AND MECHANICAL PROPERTIES OF AMORPHOUS HYDROGENATED DLC-COATED Ti-6Al-4V ELI ALLOY WITH TiCN INTERLAYER PREPARED BY rf-PECVD
    Lee, Kwangmin
    Kang, Seokil
    ARCHIVES OF METALLURGY AND MATERIALS, 2020, 65 (04) : 1357 - 1360
  • [29] Tribological performance of ultra-high-molecular-weight polyethylene sliding against DLC-coated and nitrogen ion implanted CoCrMo alloy measured in a hip joint simulator
    Liu, Hengjun
    Leng, Yongxiang
    Tang, Jinglong
    Wang, Shuo
    Xie, Dong
    Sun, Hong
    Huang, Nan
    SURFACE & COATINGS TECHNOLOGY, 2012, 206 (23): : 4907 - 4914
  • [30] Effects of high-velocity oxygen fuel metal-ceramic interlayer on the mechanical and tribological properties of Si/DLC-coated Ti-6Al-4V alloy
    Mou, Chenglong
    Yin, Pingmei
    Li, Wenbo
    Wang, Fu
    Cao, Xueqian
    Liu, Qianxi
    Shang, Lunlin
    Zhang, Guangan
    DIAMOND AND RELATED MATERIALS, 2023, 135