Fully automated QRS area measurement for predicting response to cardiac resynchronization therapy

被引:5
|
作者
Plesinger, Filip [1 ]
van Stipdonk, Antonius M. W. [2 ]
Smisek, Radovan [1 ]
Halamek, Josef [1 ]
Jurak, Pavel [1 ]
Maass, Alexander H. [3 ]
Meine, Mathias [4 ]
Vernooy, Kevin [2 ]
Prinzen, Frits W. [5 ]
机构
[1] Czech Acad Sci, Inst Sci Instruments, Brno, Czech Republic
[2] Maastricht Univ, Dept Cardiol, Med Ctr, Maastricht, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Cardiol, Groningen, Netherlands
[4] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[5] Cardiovasc Res Inst Maastricht CARIM, Dept Physiol, Maastricht, Netherlands
关键词
Heart failure; Cardiac resynchronization therapy; Vectorcardiography; QRS area; Software; Signal averaging; DURATION;
D O I
10.1016/j.jelectrocard.2019.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac resynchronization therapy (CRT) is an established treatment in patients with heart failure and conduction abnormalities. However, a significant number of patients do not respond to CRT. Currently employed criteria for selection of patients for this therapy (QRS duration and morphology) have several shortcomings. QRS area was recently shown to provide superior association with CRT response. However, its assessment was not fully automated and required the presence of an expert. Objective: Our objective was to develop a fully automated method for the assessment of vector-cardiographic (VCG) QRS area from electrocardiographic (ECG) signals. Methods: Pre-implantation ECG recordings (N = 864, 695 left-bundle-branch block, 589 men) in PDF files were converted to allow signal processing. QRS complexes were found and clustered into morphological groups. Signals were converted from 12-lead ECG to 3-lead VCG and an average QRS complex was built. QRS area was computed from individual areas in the X, Y and Z leads. Practical usability was evaluated using Kaplan-Meier plots and 5-year follow-up data. Results: The automatically calculated QRS area values were 123 48 mu V.s (mean values and SD), while the manually determined QRS area values were 116 51 ms; the correlation coefficient between the two was r = 0.97. The automated and manual methods showed the same ability to stratify the population (hazard ratios 2.09 vs 2.03, respectively). Conclusion: The presented approach allows the fully automatic and objective assessment of QRS area values. Significance: Until this study, assessing QRS area values required an expert, which means both additional costs and a risk of subjectivity. The presented approach eliminates these disadvantages and is publicly available as part of free signal-processing software.(C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [1] Vectorcardiographic QRS area as a predictor of response to cardiac resynchronization therapy
    Ghossein, Mohammed A.
    Van Stipdonk, Antonius Mw
    Prinzen, Frits W.
    Vernooy, Kevin
    [J]. JOURNAL OF GERIATRIC CARDIOLOGY, 2022, 19 (01) : 9 - 20
  • [2] Vectorcardiographic QRS area as a predictor of response to cardiac resynchronization therapy
    Mohammed A Ghossein
    Antonius MW van Stipdonk
    Frits W Prinzen
    Kevin Vernooy
    [J]. Journal of Geriatric Cardiology, 2022, 19 (01) : 9 - 20
  • [3] QRS dispersion is better than QRS duration for predicting response to cardiac resynchronization therapy
    Chavez-Gonzalez, Elibet
    Moreno-Martinez, Francisco L.
    [J]. HELLENIC JOURNAL OF CARDIOLOGY, 2016, 57 (05) : 366 - 367
  • [4] Vectorcardiographic QRS area as a novel predictor of response to cardiac resynchronization therapy
    van Deursen, Caroline J. M.
    Vernooy, Kevin
    Dudink, Elton
    Bergfeldt, Lennart
    Crijns, Harry J. G. M.
    Prinzen, Frits W.
    Wecke, Liliane
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2015, 48 (01) : 45 - 52
  • [5] Precision of automated QRS duration measurement in patients treated with cardiac resynchronization therapy
    Lund-Andersen, Casper
    Petersen, Helen H.
    Jons, Christian
    Philbert, Berit T.
    Tfelt-Hansen, Jacob
    Skovgaard, Lene T.
    Svendsen, Jesper H.
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (01) : 103 - 110
  • [6] Precision of automated QRS duration measurement in patients treated with cardiac resynchronization therapy
    Casper Lund-Andersen
    Helen H. Petersen
    Christian Jøns
    Berit T. Philbert
    Jacob Tfelt-Hansen
    Lene T. Skovgaard
    Jesper H. Svendsen
    [J]. Journal of Interventional Cardiac Electrophysiology, 2018, 52 : 103 - 110
  • [7] Predicting cardiac resynchronization response by QRS duration - The long and short of it
    Kass, DA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (12) : 2125 - 2127
  • [8] Effect of QRS area reduction and myocardial scar on the hemodynamic response to cardiac resynchronization therapy
    Okafor, Osita
    Umar, Fraz
    Zegard, Abbasin
    van Dam, Peter
    Walton, Jamie
    Stegemann, Berthold
    Marshall, Howard
    Leyva, Francisco
    [J]. HEART RHYTHM, 2020, 17 (12) : 2046 - 2055
  • [9] Change in QRS area by cardiac resynchronization therapy is associated with clinical outcomes and echocardiographic response
    Ghossein, M. A.
    Van Stipdonk, A. M. W.
    Plesinger, F.
    Kloosterman, M.
    Salden, O. A. E.
    Wouters, P.
    Meine, M.
    Maass, A. H.
    Prinzen, F. W.
    Vernooy, K.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 814 - 814
  • [10] Relation of QRS Duration to Response to Cardiac Resynchronization Therapy
    Sassone, Biagio
    Gambetti, Simona
    Bertini, Matteo
    Beltrami, Matteo
    Mascioli, Giosue
    Bressan, Sabrina
    Fuca, Giuseppe
    Pacchioni, Federico
    Pedaci, Mario
    Michelotti, Federica
    Reggiani, Maria Letizia Bacchi
    Padeletti, Luigi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (02): : 214 - 219