Effect of Straightening the Parent Vessels in Stent-Assisted Coil Embolization for Anterior Communicating Artery Aneurysms

被引:8
|
作者
Funakoshi, Yusuke [1 ]
Imamura, Hirotoshi [1 ]
Tani, Shoichi [1 ]
Adachi, Hidemitsu [1 ]
Fukumitsu, Ryu [1 ]
Sunohara, Tadashi [1 ]
Suzuki, Keita [1 ]
Omura, Yoshihiro [1 ]
Matsui, Yuichi [1 ]
Sasaki, Natsuhi [1 ]
Bando, Toshiaki [2 ]
Fukuda, Tatsumaru [1 ]
Akiyama, Ryo [1 ]
Horiuchi, Kazufumi [1 ]
Kajiura, Shinji [1 ]
Shigeyasu, Masashi [1 ]
Sakai, Nobuyuki [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Neurosurg, Kobe, Hyogo, Japan
[2] Shinko Hosp, Dept Neurosurg & Stroke Ctr, Kobe, Hyogo, Japan
关键词
Aneurysmal stenting; Anterior communicating artery; Progressive thrombosis; Stent-assisted coil embolization; Straightening of parent vessels; ENDOVASCULAR TREATMENT; INTRACRANIAL ANEURYSMS;
D O I
10.1016/j.wneu.2019.02.066
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Stent-assisted coil embolization (SAC) for treating anterior communicating artery (AcomA) aneurysms is safe and effective. Straightening of parent vessels by stent placement can lead to progressive thrombosis. We describe our experience with SAC for AcomA aneurysms and demonstrate the effect of straightening the parent vessels. METHODS: A total of 26 patients with AcomA aneurysms were treated using SAC in our institute between July 2010 and December 2017. Follow-up digital subtraction angiography was performed 6 months after treatment, magnetic resonance angiography was performed every year, and outcomes were analyzed. RESULTS: From all aneurysms (n = 24), 12 (50.0%) were neck remnant, and 12 (50.0%) were dome-filling types immediately after the procedure. At the 6-month digital subtraction angiography follow-up (n = 22), 13 (59.1%) aneurysms were complete obliteration, 8 (36.4%) were neck remnant, and 1 (4.5%) was dome filling. The median parent vessel anglewas measured preoperatively at 98.1 degrees, increased to 124.8 degrees immediately after stent deployment, and further increased to 149.6 degrees at the 6-month follow-up. Progressive thrombosis was observed in 13 of 22 (59.1%) aneurysms. The parent vessel angle change immediately after stent deployment in the progressive thrombosis group tended to be larger than that observed in the no thrombosis group; this change was significant at the 6-month follow-up. The median followup term was 18 months. No patients required retreatment. CONCLUSIONS: Good SAC outcomes were achieved for AcomA aneurysms, and hemodynamic changes related to straightening of the parent vessels is a consideration in SAC.
引用
收藏
页码:E410 / E416
页数:7
相关论文
共 50 条
  • [31] Safety and Efficacy of Tirofiban in Stent-Assisted Coil Embolization of Intracranial Aneurysms
    Chalouhi, Nohra
    Jabbour, Pascal
    Kung, David
    Hasan, David
    [J]. NEUROSURGERY, 2012, 71 (03) : 710 - 714
  • [32] Stent-assisted coil embolization of intracranial aneurysms: A single center experience
    Luo, Chao-Bao
    Teng, Michael Mu-Huo
    Chang, Feng-Chi
    Lin, Chung-Jung
    Guo, Wan-Yuo
    Chang, Cheng-Yen
    [J]. JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2012, 75 (07) : 322 - 328
  • [33] Stent-assisted coil embolization of intracranial wide-necked aneurysms
    Lee, YJ
    Kim, DJ
    Suh, SH
    Lee, SK
    Kim, J
    Kim, DI
    [J]. NEURORADIOLOGY, 2005, 47 (09) : 680 - 689
  • [34] Anatomic Results and Complications of Stent-Assisted Coil Embolization of Intracranial Aneurysms
    Kim, S. -R.
    Vora, N.
    Jovin, T. G.
    Gupta, R.
    Thomas, A.
    Kassam, A.
    Lee, K.
    Gologorsky, Y.
    Jankowitz, B.
    Panapitiya, N.
    Aleu, A.
    Sandhu, E.
    Crago, E.
    Hricik, A.
    Gallek, M.
    Horowitz, M. B.
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2008, 14 (03) : 267 - 284
  • [35] Stent-assisted coil embolization of intracranial wide-necked aneurysms
    Young-Jun Lee
    Dong Joon Kim
    Sang Hyun Suh
    Seung-Koo Lee
    Jinna Kim
    Dong Ik Kim
    [J]. Neuroradiology, 2005, 47 : 680 - 689
  • [36] Stent-assisted coil embolization Response
    Chung, Joonho
    Shin, Yong Sam
    [J]. JOURNAL OF NEUROSURGERY, 2014, 121 (01) : 2 - 3
  • [37] Stent-assisted coil embolization of MCA aneurysm via a trans-posterior communicating artery access
    Joshi, Krishna C.
    Heiferman, Daniel F.
    Beer-Furlan, Andre
    Lopes, Demetrius K.
    [J]. NEUROSURGICAL FOCUS, 2019, 46
  • [38] Neuroform Stent-Assisted Embolization of Incidental Anterior Communicating Artery Aneurysms: Long-term Clinical and Angiographic Follow-up
    Raslan, Ahmed M.
    Oztaskin, Murat
    Thompson, Eric M.
    Dogan, Aclan
    Petersen, Bryan
    Nesbit, Gary
    Lee, David S.
    Barnwell, Stanley L.
    [J]. NEUROSURGERY, 2011, 69 (01) : 27 - 37
  • [39] Comparative analysis of coil embolization in posterior and anterior communicating artery aneurysms
    Choi, Hyun Ho
    Cho, Young Dae
    Yoo, Dong Hyun
    Lee, Su Hwan
    Yeon, Eung Koo
    Kang, Hyun-Seung
    Cho, Won-Sang
    Kim, Jeong Eun
    Han, Moon Hee
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (08) : 790 - 795
  • [40] Clinical results and pathological findings of stent-assisted coil embolization for basilar artery trunk dissecting aneurysms
    Nagashima, H
    Hongo, K
    Matsumoto, Y
    Oya, F
    Kobayashi, S
    Higuchi, K
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2003, 9 : 95 - 99