Development of a Portable, Reliable and Low-Cost Electrical Impedance Tomography System Using an Embedded System

被引:25
|
作者
Zamora-Arellano, Francisco [1 ]
Roberto Lopez-Bonilla, Oscar [1 ]
Efren Garcia-Guerrero, Enrique [1 ]
Everardo Olguin-Tiznado, Jesus [1 ]
Inzunza-Gonzalez, Everardo [1 ]
Lopez-Mancilla, Didier [2 ]
Tlelo-Cuautle, Esteban [3 ]
机构
[1] Autonomous Univ Baja California UABC, Fac Engn Architecture & Design, Ensenada 22860, Baja California, Mexico
[2] Univ Guadalajara UDG, Ctr Univ Los Lagos, Guadalajara 47460, Jalisco, Mexico
[3] Inst Nacl Astrofis Opt & Elect INAOE, Dept Elect, Puebla 72840, Mexico
关键词
electrical impedance tomography; EIT; image reconstruction; embedded system; Raspberry Pi 4; electronic instrumentation; DESIGN; BRAIN;
D O I
10.3390/electronics10010015
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical impedance tomography (EIT) is a useful procedure with applications in industry and medicine, particularly in the lungs and brain area. In this paper, the development of a portable, reliable and low-cost EIT system for image reconstruction by using an embedded system (ES) is introduced herein. The novelty of this article is the hardware development of a complete low-cost EIT system, as well as three simple and efficient algorithms that can be implemented on ES. The proposed EIT system applies the adjacent voltage method, starting with an impedance acquisition stage that sends data to a Raspberry Pi 4 (RPi4) as ES. To perform the image reconstruction, a user interface was developed by using GNU Octave for RPi4 and the EIDORS library. A statistical analysis is performed to determine the best average value from the samples measured by using an analog-to-digital converter (ADC) with a capacity of 30 kSPS and 24-bit resolution. The tests for the proposed EIT system were performed using materials such as metal, glass and an orange to simulate its application in food industry. Experimental results show that the statistical median is more accurate with respect to the real voltage measurement; however, it represents a higher computational cost. Therefore, the mean is calculated and improved by discarding data values in a transitory state, achieving better accuracy than the median to determine the real voltage value, enhancing the quality of the reconstructed images. A performance comparison between a personal computer (PC) and RPi4 is presented. The proposed EIT system offers an excellent cost-benefit ratio with respect to a traditional PC, taking into account precision, accuracy, energy consumption, price, light weight, size, portability and reliability. The proposed EIT system has potential application in mechanical ventilation, food industry and structural health monitoring.
引用
收藏
页码:1 / 24
页数:24
相关论文
共 50 条
  • [31] DAQ based Impedance Measurement System for Low Cost and Portable Electrical Cell-Substrate Impedance Sensing
    Il-Hwan Park
    Yeonhee Hong
    Hee-Sook Jun
    Eou-Sik Cho
    Sungbo Cho
    [J]. BioChip Journal, 2018, 12 : 18 - 24
  • [32] DAQ based Impedance Measurement System for Low Cost and Portable Electrical Cell-Substrate Impedance Sensing
    Park, Il-Hwan
    Hong, Yeonhee
    Jun, Hee-Sook
    Cho, Eou-Sik
    Cho, Sungbo
    [J]. BIOCHIP JOURNAL, 2018, 12 (01) : 18 - 24
  • [33] Portable impedance measurement system based on Embedded System
    Luo Xiaohui
    [J]. PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL & ELECTRONICS ENGINEERING AND COMPUTER SCIENCE (ICEEECS 2016), 2016, 50 : 114 - 117
  • [34] BUILDING A SIMPLE RELIABLE LOW-COST MODELOCKER SYSTEM
    ALBRECHT, GF
    LUND, L
    SMITH, D
    [J]. APPLIED OPTICS, 1983, 22 (09) : 1276 - 1280
  • [35] A RELIABLE LOW-COST MOORING SYSTEM FOR OCEANOGRAPHIC INSTRUMENTATION
    PILLSBUR.D
    SMITH, RL
    TIPPER, RC
    [J]. LIMNOLOGY AND OCEANOGRAPHY, 1969, 14 (02) : 307 - &
  • [36] Tomo: Wearable, Low-Cost, Electrical Impedance Tomography for Hand Gesture Recognition
    Zhang, Yang
    Harrison, Chris
    [J]. UIST'15: PROCEEDINGS OF THE 28TH ANNUAL ACM SYMPOSIUM ON USER INTERFACE SOFTWARE AND TECHNOLOGY, 2015, : 167 - 173
  • [37] Practical Design of Low-cost Instrumentation For Industrial Electrical Impedance Tomography (EIT)
    Khalighi, Mohammad
    Vahdat, Bijan Vosoughi
    Mortazavi, Mohammad
    Wei, H. Y.
    Soleimani, Manuchehr
    [J]. 2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1259 - 1263
  • [38] A low-cost, portable biopotential monitoring system to study electrical activities of the human brain and body
    Bandara, Vibodha
    Nanayakkara, Asiri
    [J]. EUROPEAN JOURNAL OF PHYSICS, 2020, 41 (06)
  • [39] A low-cost cryptographic processor for security embedded system
    Lu, Ronghua
    Han, Jun
    Zeng, Xiaoyang
    Li, Qing
    Mai, Lang
    Zhao, Jia
    [J]. 2008 ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE, VOLS 1 AND 2, 2008, : 19 - 20
  • [40] Low-cost Embedded Control System for Environmental Monitoring
    Palczynska, Beata
    Rabczuk, Dorota
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,