Customized correction of wavefront aberrations in abnormal human eyes by using a phase plate and a customized contact lens

被引:0
|
作者
Jeong, Tae Moon [1 ]
Yoon, Geunyoung
机构
[1] Gwangju Inst Sci & Technol, Adv Photon Res Inst, Kwangju 500712, South Korea
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
关键词
eye; wavefront; Shack-Hartmann wavefront sensor; phase plate; customized contact lens; RETINAL IMAGE QUALITY; BENEFIT;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Wavefront aberrations in human eyes were measured with a Shack-Hartmann wavefront sensor. Based on the measured wavefront aberrations, customized optics, such as phase plates and a customized contact lens, were designed and fabricated to compensate for higher-order wavefront aberrations in human eyes. The fabricated customized optics could successfully correct higher-order aberrations in human eyes and improve retinal image quality, and compensating for such aberrations with customized optics might be a promising technique to improve human vision.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 19 条
  • [1] Wavefront-customized soft contact lenses for high-order aberration correction in normal eyes
    Akers, Donnie
    Asimellis, George
    Karageorgiadis, Lefteris
    Katsoulos, Costas
    Vasileiou, Nikos
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [3] Vision improvement using customized optics in normal and abnormal eyes
    Jeong, T
    Yoon, G
    Williams, DR
    Cox, IG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U398 - U398
  • [4] Vision improvement using customized optics in normal and abnormal eyes
    Jeong, T
    Yoon, G
    Williams, DR
    Cox, IG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] A Study about Human Eyes Wavefront Aberrations Capture and Correction
    Toadere, F.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 101 - 104
  • [6] Position tolerance analysis for wavefront aberrations correction of human eyes
    Zhao, Haoxing
    Xu, Bing
    Guangxue Xuebao/Acta Optica Sinica, 2008, 28 (05): : 949 - 954
  • [7] Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
    Sabesan, Ramkumar
    Jeong, Tae Moon
    Carvalho, Luis
    Cox, Ian G.
    Williams, David R.
    Yoon, Geunyoung
    OPTICS LETTERS, 2007, 32 (08) : 1000 - 1002
  • [8] A novel approach to wavefront-guided contact lenses: Aberrations approaching manufacturing tolerances using a surface-customized fitting algorithm
    Schill, Alexander W.
    Maddah, Nasim
    Elam, Evan S.
    Marsack, Jason D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [9] Aberration correction using customized soft contact lenses with aspheric and asymmetric surfaces
    Lopez-Gil, N
    Benito, A
    Castejón-Mochón, JF
    Marín, JM
    Lo-a-Foe, G
    Marin, G
    Fermigier, B
    Joyeux, D
    Chateau, N
    Artal, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U213 - U213
  • [10] An approach for iris contact lens detection and classification using ensemble of customized DenseNet and SVM
    Choudhary, Meenakshi
    Tiwari, Vivek
    Venkanna, U.
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2019, 101 : 1259 - 1270