The Electromagnetic Calorimeter of the CMS Experiment

被引:0
|
作者
Pastrone, Nadia [1 ]
机构
[1] Ist Nazl Fis Nucl, I-10125 Turin, Italy
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The CMS electromagnetic calorimeter, made of about 76000 Lead Tungstate scintillating crystals, aims to achieve an extreme precision in the energy measurement of photon and electrons. Main challenges, measured performance and commissioning studies for the start up of LHC collider will be discussed.
引用
收藏
页码:1964 / 1970
页数:7
相关论文
共 50 条
  • [31] Calibration of the CMS electromagnetic calorimeter
    Paramatti, R
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 107 - 111
  • [32] Overview of the CMS electromagnetic calorimeter
    Heath, HF
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 384 - 388
  • [33] Design and performance of the Phase 2 CMS experiment electromagnetic calorimeter readout electronics
    Basile, C.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2024, 47 (03):
  • [34] Beam tests of the trigger and digital processing electronics for the electromagnetic calorimeter of the CMS experiment
    Benetta, R
    Hansen, M
    Lofsted, B
    Varela, J
    Lecomte, P
    Nessi-Tedaldi, F
    Almeida, A
    Machado, E
    Nobrega, R
    da Silva, JC
    Silva, S
    Bercher, M
    Bourotte, J
    Buiron, L
    Busson, P
    Faurlini, L
    Lecouturier, D
    Matricon, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (01): : 31 - 42
  • [35] Beam tests of the trigger and digital processing electronics for the electromagnetic calorimeter of the CMS experiment
    CERN, Geneva, Switzerland
    Nucl Instrum Methods Phys Res Sect A, 1 (31-42):
  • [36] Calibration of the very-front-end electronics for the electromagnetic calorimeter of the CMS experiment
    Blaha, J.
    Combaret, C.
    Fay, J.
    Maurelli, G.
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : C401 - C408
  • [37] Avalanche photodiodes for the CMS electromagnetic calorimeter
    Longo, E
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 406 - 412
  • [38] Avalanche photodiodes for the CMS electromagnetic calorimeter
    Organtini, Giovanni
    IEEE Transactions on Nuclear Science, 1999, 46 (3 I): : 243 - 249
  • [39] Crystal properties in the electromagnetic calorimeter of CMS
    Paramatti, Riccardo
    Calorimetry in High Energy Physics, 2006, 867 : 245 - 251
  • [40] The CMS lead tungstate electromagnetic calorimeter
    Rusack, RW
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 99 - 108