Computed Tomography (CT) of the Chest at Less Than 1 mSv: An Ongoing Prospective Clinical Trial of Chest CT at Submillisievert Radiation Doses with Iterative Model Image Reconstruction and iDose4 Technique

被引:54
|
作者
Khawaja, Ranish Deedar Ali [1 ,2 ]
Singh, Sarabjeet [1 ,2 ]
Gilman, Matthew [1 ,2 ]
Sharma, Amita [1 ,2 ]
Do, Synho [1 ,2 ]
Pourjabbar, Sarvenaz [1 ,2 ]
Padole, Atul [1 ,2 ]
Lira, Diego [1 ,2 ]
Brown, Kevin [3 ]
Shepard, Jo-Anne O. [1 ,2 ]
Kalra, Mannudeep K. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, MGH Imaging, Div Thorac Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Philips Healthcare Res Team, Cleveland, OH USA
关键词
chest CT; lower radiation dose; iterative reconstruction technique; image quality; FILTERED BACK-PROJECTION; LOW-TUBE-VOLTAGE; QUALITY; REDUCTION; ALGORITHMS; EXPERIENCE; IMPACT; SPACE; NOISE; FBP;
D O I
10.1097/RCT.0000000000000087
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess lesion detection and diagnostic confidence of computed tomography (CT) of the chest performed at less than 1 mSv with 2 iterative reconstruction (IR) techniques. Materials and Methods: Ten patients gave written informed consent for the acquisitions of images at submillisievert dose (0.9 mSv), in addition to clinical standard-dose (SD) chest CT (2.9 mSv). Submillisievert images were reconstructed with iDose(4) and iterative model reconstruction (IMR). Two radiologists assessed lesion detection, margins, diagnostic confidence, and visibility of small structures. Objective noise and noise spectral density were measured. Results: Lesion detection was identical for standard-dose filtered back projection (FBP), submSv iDose(4), and submSv IMR. Lesion margins were better seen for 30% of detected lung lesions with submSv IMR compared to standard-dose FBP and submSv iDose(4) (P < 0.05). Visibility of abdominal structures, and diagnostic confidence with submSv iDose(4) and submSv IMR were similar to standard-dose FBP. There was 21% to 64% noise reduction with submSv IMR and 1% to 15% higher noise with iDose(4) compared to standard-dose FBP (P < 0.0001). Conclusions: Submillisievert IMR improves delineation of lesion margins compared to standard-dose FBP and submSv iDose(4).
引用
收藏
页码:613 / 619
页数:7
相关论文
共 5 条
  • [1] Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose4™
    Laqmani, Azien
    Avanesov, Maxim
    Butscheidt, Sebastian
    Kurfuerst, Maximilian
    Sehner, Susanne
    Schmidt-Holtz, Jakob
    Derlin, Thorsten
    Behzadi, Cyrus
    Nagel, Hans D.
    Adam, Gerhard
    Regier, Marc
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (11) : 1971 - 1979
  • [2] Patient radiation exposure and image quality evaluation with the use of iDose4 iterative reconstruction algorithm in chest-abdomen-pelvis CT examinations
    Ploussi, Agapi
    Alexopoulou, Efthymia
    Economopoulos, Nikolaos
    Argentos, Stylianos I.
    Tsitsia, Vasiliki
    Arapakis, Ioannis
    Kordolaimi, Sofia
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 158 (04) : 399 - 405
  • [3] Using "iDose4" iterative reconstruction algorithm in adults' chest-abdomen-pelvis CT examinations: effect on image quality in relation to patient radiation exposure
    Arapakis, I.
    Efstathopoulos, E.
    Tsitsia, V.
    Kordolaimi, S.
    Economopoulos, N.
    Argentos, S.
    Ploussi, A.
    Alexopoulou, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036):
  • [4] CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP
    Laqmani, Azien
    Kurfuerst, Maximillian
    Butscheidt, Sebastian
    Sehner, Susanne
    Schmidt-Holtz, Jakob
    Behzadi, Cyrus
    Nagel, Hans Dieter
    Adam, Gerhard
    Regier, Marc
    [J]. PLOS ONE, 2016, 11 (09):
  • [5] Automatic current selection with iterative reconstruction reduces effective dose to less than 1 mSv in low-dose chest computed tomography in persons with normal BMI
    Chen, Li-Guo
    Wu, Ping-An
    Sheu, Min-Huei
    Tu, Hsing-Yang
    Huang, Li-Chuan
    [J]. MEDICINE, 2019, 98 (28)