Surgical Paddle-Lead Placement for Screening Trials of Spinal Cord Stimulation

被引:11
|
作者
Pahapill, Peter A. [1 ]
机构
[1] United Neurosurg Associates, Naseff Specialty Ctr, St Paul, MN USA
来源
NEUROMODULATION | 2014年 / 17卷 / 04期
关键词
Case series; chronic pain; electrode paddle; SCS; spinal cord stimulation; BACK SURGERY SYNDROME; CONVENTIONAL MEDICAL-MANAGEMENT; NEUROPATHIC PAIN; COST-EFFECTIVENESS; FOLLOW-UP;
D O I
10.1111/ner.12084
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectivesSpinal cord stimulation (SCS) has become an evidence-based treatment for a variety of chronic pain disorders. A key step in appropriate patient selection and long-term outcome predictability is a percutaneous screening trial of stimulation. Occasionally, a trial cannot be adequately completed with a percutaneous electrode. Rather than depriving this therapy from these patients, the authors have developed a program providing surgically implanted paddle-lead screening trials of SCS. MethodsData from 22 patients undergoing paddle-lead screening trials of SCS from October 2009 to August 2012 were retrospectively reviewed. The surgical paddle leads were positioned with thoracic or cervical laminotomies under local anesthetic and conscious sedation, allowing awakened patients to confirm optimal lead placement. Externalized lead extensions were connected to an external pulse generator for a five-day screening trial. Pain reduction of at least 50% was required for patients to have the previously implanted paddle lead connected to an internalized pulse generator; otherwise, the trial surgical paddle leads were removed. ResultsTwenty-two patients received five-day paddle-lead stimulation screening trials for various chronic neuropathic pain conditions. All paddle screening trials were well tolerated and completed as outpatient procedures. Sixteen patients received fully implanted systems. At an average follow-up of 23 months, all implanted patients continue to have satisfactory pain control. There were no infections, lead migrations, or revisions. ConclusionsSurgically implanted paddle-lead screening trials of SCS can be used safely and effectively in those patients in which an adequate percutaneous-electrode trial cannot be completed. Results are similar to those seen with standard percutaneous screening trials. A systematic approach to surgical-paddle screening trials of SCS has not been previously reported.
引用
收藏
页码:346 / 348
页数:3
相关论文
共 50 条
  • [31] Techniques for Safe Removal of Spinal Cord Stimulation Paddle Leads
    Topp, Gregory
    Harland, Tessa
    Spurgas, Morgan
    Rock, Andrew
    Pilitsis, Julie G.
    OPERATIVE NEUROSURGERY, 2022, 23 (06) : E348 - E352
  • [32] Placement of spinal cord stimulation paddle leads in the thoracic spine using en bloc laminoplasty: A technical note
    Stegelmann, Samuel D.
    Rahmani, Roman
    Yim, Jae Min
    Ahammad, Zubair
    WORLD NEUROSURGERY-X, 2024, 24
  • [33] Analysis of spinal canal diameter in the placement of thoracic spinal cord stimulator paddle leads
    Ragel, Brian T.
    Riedman, Tressa
    Mcgehee, Matthew
    Raslan, Ahmed M.
    PAIN PRACTICE, 2024, 24 (01) : 91 - 100
  • [34] Permanent trials for spinal cord stimulation
    Bandlamuri, Sruti
    Harland, Tessa A.
    Pilitsis, Julie G.
    Sukul, Vishad V.
    PAIN PRACTICE, 2025, 25 (02)
  • [35] Percutaneous Spinal Cord Stimulation Lead Placement Under Deep Sedation and General Anesthesia
    Hasoon, Jamal
    Urits, Ivan
    Viswanath, Omar
    Varrassi, Giustino
    Simopoulos, Thomas T.
    Kohan, Lynn
    Gutierrez, Genaro
    Orhurhu, Vwaire
    Aner, Musa
    Gill, Jatinder
    PAIN AND THERAPY, 2021, 10 (02) : 1719 - 1730
  • [36] Percutaneous Spinal Cord Stimulation Lead Placement Under Deep Sedation and General Anesthesia
    Jamal Hasoon
    Ivan Urits
    Omar Viswanath
    Giustino Varrassi
    Thomas T. Simopoulos
    Lynn Kohan
    Genaro Gutierrez
    Vwaire Orhurhu
    Musa Aner
    Jatinder Gill
    Pain and Therapy, 2021, 10 : 1719 - 1730
  • [37] Epidural spinal cord stimulation with a multiple electrode paddle lead is effective in treating intractable low back pain
    Barolat, G
    Oakley, JC
    Law, JD
    North, RB
    Ketcik, B
    Sharan, A
    NEUROMODULATION, 2001, 4 (02): : 59 - 66
  • [38] Placement of Surgical Spinal Cord Stimulation Leads Using Spinal Process Splitting Laminotomy: Technical Note
    Thissen, Jost
    Bara, Gregor A.
    WORLD NEUROSURGERY, 2021, 155 : 109 - 114
  • [39] Rate of Complications Following Spinal Cord Stimulation Paddle Electrode Removal
    Maldonado-Naranjo, Andres L.
    Frizon, Leonardo A.
    Sabharwal, Navin C.
    Xiao, Roy
    Hogue, Olivia
    Lobel, Darlene A.
    Machado, Andre G.
    Nagel, Sean J.
    NEUROMODULATION, 2018, 21 (05): : 513 - 519
  • [40] Analysis of Spinal Canal Diameter in the Placement of Thoracic Spinal Cord Stimulator (SCS) Paddle Leads
    Riedman, Tressa
    Ragel, Brian
    McGehee, Matthew
    Raslan, Ahmed
    JOURNAL OF NEUROSURGERY, 2022, 136 (05)