DC-bias-voltage dependence of degradation of aluminum electrolytic capacitors

被引:11
|
作者
Hasegawa, K. [1 ]
Tsuzaki, K. [1 ]
Nishizawa, S. [2 ]
机构
[1] Kyushu Inst Technol, Dept Biol Funct Engn, Wakamatsu Ku, 2-4 Hibikino, Kitakyushu, Fukuoka 8080196, Japan
[2] Kyushu Univ, Res Inst Appl Mech, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
关键词
FILM CAPACITORS;
D O I
10.1016/j.microrel.2018.02.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attention has been paid to reliability-related issues for dc-link capacitors such as monitoring methods, power loss estimation, and ageing tests. The degradation of the capacitors depends on their operating condition including temperature, ripple current, and dc-bias voltage, which has a strong influence on failures as well. In design stages of power converters, it is desirable to know the relation between the degradation and electrolytic parameters. This paper makes an intensive discussion on the voltage dependence of the degradation of a small aluminum electrolytic capacitor with an ageing test and a leakage-current measurement. The ageing test reveals that a higher dc-bias voltage brings a faster increase in ESR but results in a slower drop in capacitance in a range within the rated voltage. This result implies that either capacitance or ESR cannot be a unique indicator of the lifetime. Attention should be paid both to the ESR and to the capacitance when one monitors the capacitor condition. On the other hand, more than the rated voltage leads a rapid degradation of the capacitor, which can be confirmed by a leakage-current measurement instead of the ageing test.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 50 条
  • [31] RESIDUAL VOLTAGE OF TANTALUM OXIDE ELECTROLYTIC CAPACITORS
    DREINER, R
    SCHIMMEL, J
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1962, 109 (03) : C63 - C64
  • [32] THERMOGRAVIMETRIC STUDIES ON ALUMINUM FOILS FOR ELECTROLYTIC CAPACITORS
    KOMIVES, J
    GAL, S
    TOMOR, K
    KOVACS, G
    JOURNAL OF THERMAL ANALYSIS, 1983, 27 (02): : 315 - 324
  • [33] Symmetric Pulsed Anodizing of Aluminum Foil for Aluminum Electrolytic Capacitors
    Li, Xiang
    Lin, Baige
    Xiong, Lilong
    Du, Xianfeng
    ACS APPLIED ENERGY MATERIALS, 2020, 3 (02) : 1804 - 1810
  • [34] DEGRADATION ANALYSIS OF DC-LINK ALUMINIUM ELECTROLYTIC CAPACITORS OPERATING IN PWM POWER CONVERTERS
    Enisz, Krisztian
    Kohlrusz, Gabor
    Fodor, Denes
    Kovacs, Laszlo
    Marschalko, Richard
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 18 (02) : 85 - 91
  • [35] Test Fixtures to Apply Variable DC Bias and AC Ripple Current for Reliability Testing of Electrolytic Capacitors
    Wang, Xuechao
    Karami, Marzieh
    Tallam, Rangarajan M.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 4073 - 4079
  • [36] Dissipation Factor as a Degradation Indicator for Electrolytic Capacitors
    Ghadrdan, Moein
    Peyghami, Saeed
    Mokhtari, Hossein
    Wang, Huai
    Blaabjerg, Frede
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (01) : 1035 - 1044
  • [37] Estimating Aluminum Electrolytic Capacitors Condition Using a Low Frequency Transformer Together with a DC Power Supply
    Amaral, Acacio M. R.
    Marques Cardoso, A. J.
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 2010), 2010, : 815 - 820
  • [38] Field angle dependence of voltage-induced ferromagnetic resonance under DC bias voltage
    Shiota, Yoichi
    Miwa, Shinji
    Tamaru, Shingo
    Nozaki, Takayuki
    Kubota, Hitoshi
    Fukushima, Akio
    Suzuki, Yoshishige
    Yuasa, Shinji
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2016, 400 : 159 - 162
  • [40] Measurement and analysis of low-frequency noise in large capacity high voltage aluminum electrolytic capacitors
    Wu Yong
    Ma Zhongfa
    Du Lei
    He Liang
    2014 15TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY (ICEPT), 2014, : 1127 - 1132