Diagnostic accuracy of DXA compared to conventional spine radiographs for the detection of vertebral fractures in children

被引:20
|
作者
Adiotomre, E. [1 ,2 ]
Summers, L. [3 ]
Allison, A. [4 ]
Walters, S. J. [4 ]
Digby, M. [3 ]
Broadley, P. [2 ]
Lang, I. [2 ]
Morrison, G. [5 ]
Bishop, N. [6 ]
Arundel, P. [6 ]
Offiah, A. C. [2 ,6 ]
机构
[1] Sheffield Teaching Hosp NHS Fdn Trust, Radiol Dept, Glossop Rd, Sheffield S10 2JF, S Yorkshire, England
[2] Sheffield Childrens Hosp NHS Fdn Trust, Radiol Dept, Western Bank, Sheffield S10 2TH, S Yorkshire, England
[3] Univ Sheffield, Sheffield Med Sch, Beech Hill Rd, Sheffield S10 2RX, S Yorkshire, England
[4] Univ Sheffield, Sch Hlth & Related Res, 30 Regent St, Sheffield S1 4DA, S Yorkshire, England
[5] Sheffield Teaching Hosp NHS Fdn Trust, Med Phys, Glossop Rd, Sheffield S10 2JF, S Yorkshire, England
[6] Univ Sheffield, Acad Unit Child Hlth, Western Bank, Sheffield S10 2TH, S Yorkshire, England
基金
美国国家卫生研究院;
关键词
Spinal fractures; Osteoporosis; Interobserver variability; Dual energy x-ray absorptiometry; Radiography; X-RAY ABSORPTIOMETRY; OSTEOPOROSIS; CANCER; RISK; DENSITOMETRY; RADIATION; RELIABILITY; CHILDHOOD; EXPOSURE; SCANS;
D O I
10.1007/s00330-016-4556-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In children, radiography is performed to diagnose vertebral fractures and dual energy x-ray absorptiometry (DXA) to assess bone density. In adults, DXA assesses both. We aimed to establish whether DXA can replace spine radiographs in assessment of paediatric vertebral fractures. Prospectively, lateral spine radiographs and lateral spine DXA of 250 children performed on the same day were independently scored by three radiologists using the simplified algorithm-based qualitative technique and blinded to results of the other modality. Consensus radiograph read and second read of 100 random images were performed. Diagnostic accuracy, inter/intraobserver and intermodality agreements, patient/carer experience and radiation dose were assessed. Average sensitivity and specificity (95 % confidence interval) in diagnosing one or more vertebral fractures requiring treatment was 70 % (58-82 %) and 97 % (94-100 %) respectively for DXA and 74 % (55-93 %) and 96 % (95-98 %) for radiographs. Fleiss' kappa for interobserver and average kappa for intraobserver reliability were 0.371 and 0.631 respectively for DXA and 0.418 and 0.621 for radiographs. Average effective dose was 41.9 mu Sv for DXA and 232.7 mu Sv for radiographs. Image quality was similar. Given comparable image quality and non-inferior diagnostic accuracy, lateral spine DXA should replace conventional radiographs for assessment of vertebral fractures in children. aEuro cent Vertebral fracture diagnostic accuracy of lateral spine DXA is non-inferior to radiographs. aEuro cent The rate of unreadable vertebrae for DXA is lower than for radiographs. aEuro cent Effective dose of DXA is significantly lower than radiographs. aEuro cent Children prefer DXA to radiographs. aEuro cent Given the above, DXA should replace radiographs for paediatric vertebral fracture assessment.
引用
收藏
页码:2188 / 2199
页数:12
相关论文
共 50 条
  • [31] Osteoporotic Vertebral Fractures in the Elderly: Are Conventional Radiographs Useful? - Clinical and Radiographic Results after Kyphoplasty
    Wick, M.
    Petraschka, C.
    Kronawitter, P.
    Cidlinsky, K.
    Heyer, C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (06): : 641 - 645
  • [32] Accuracy of physical examination for detection of thoracic vertebral fractures.
    Siminoski, K
    Warshawski, R
    Jen, H
    Lee, K
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S274 - S274
  • [33] The accuracy of historical height loss for detection of prevalent vertebral fractures
    Siminoski, K
    Lee, K
    Jen, H
    Warshawski, R
    JOURNAL OF RHEUMATOLOGY, 2004, 31 (07) : 1432 - 1432
  • [34] DIAGNOSTIC ACCURACY OF MODIFIED CPIS WITHOUT CHEST RADIOGRAPHS COMPARED TO FULL CPIS
    Munro, Cindy
    Grap, Mary Jo
    Elswick, R. K.
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U137 - U137
  • [35] COMPARISON OF DIAGNOSTIC PERFORMANCE OF SPINE AND HIP DXA EVALUATION OF BONE-DENSITY IN FRAGILITY FRACTURES
    TREVISAN, C
    BIANCHI, ML
    GANDOLINI, G
    CHERUBINI, R
    ORTOLANI, S
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S358 - S358
  • [36] Diagnosis of vertebral deformities on chest CT and DXA compared to routine lateral thoracic spine X-ray
    van Dort, M. J.
    Romme, E. A. P. M.
    Smeenk, F. W. J. M.
    Geusens, P. P. P. M.
    Wouters, E. F. M.
    van den Bergh, J. P.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 (06) : 1285 - 1293
  • [37] Diagnosis of vertebral deformities on chest CT and DXA compared to routine lateral thoracic spine X-ray
    M. J. van Dort
    E. A. P. M. Romme
    F. W. J. M. Smeenk
    P. P. P. M. Geusens
    E. F. M. Wouters
    J. P. van den Bergh
    Osteoporosis International, 2018, 29 : 1285 - 1293
  • [38] Amplitude Integrated Electroencephalography Compared With Conventional Video EEG for Neonatal Seizure Detection: A Diagnostic Accuracy Study
    Rakshasbhuvankar, Abhijeet
    Rao, Shripada
    Palumbo, Linda
    Ghosh, Soumya
    Nagarajan, Lakshmi
    JOURNAL OF CHILD NEUROLOGY, 2017, 32 (09) : 815 - 822
  • [39] Detection of experimentally induced root fractures on digital and conventional radiographs: an in vitro study
    Athena Kondylidou-Sidira
    Anastasia Fardi
    Michaela Giannopoulou
    Nikolaos Parisis
    Odontology, 2013, 101 : 89 - 95
  • [40] Detection of experimentally induced root fractures on digital and conventional radiographs: an in vitro study
    Kondylidou-Sidira, Athena
    Fardi, Anastasia
    Giannopoulou, Michaela
    Parisis, Nikolaos
    ODONTOLOGY, 2013, 101 (01) : 89 - 95