Ultrasonic biopsy needle based on the class IV flextensional configuration

被引:0
|
作者
Mathieson, Andrew [1 ]
Feeney, Andrew [1 ]
Tweedie, Andrew [2 ]
Lucas, Margaret [1 ]
机构
[1] Univ Glasgow, Sch Engn, Glasgow, Lanark, Scotland
[2] Thornton Tomasetti, Glasgow, Lanark, Scotland
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/ULTSYM.2015.0213
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study builds on previous research by the authors, where the design of a miniaturized class IV transducer configuration and adaption for including an end-effector for use in biopsy are investigated. Device design has focused on the generation of displacement uniformity across the output surface of the transducer. This has the aim of maximizing device reliability and minimizing nonlinear responses that could adversely affect the performance of devices incorporating end-effectors. The devices investigated in this study, designed using finite element analysis, have been experimentally characterized to identify their impedance and resonant characteristics.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] PET-Based Percutaneous Needle Biopsy
    El-Haddad, Ghassan
    PET CLINICS, 2016, 11 (03) : 333 - +
  • [22] NONPALPABLE MAMMARY ABNORMALITIES - USEFULNESS OF FINE NEEDLE-BIOPSY AFTER ULTRASONIC LOCALIZATION
    TRAVADE, A
    DAUPLAT, J
    PTAK, Y
    LAFAYE, C
    PRESSE MEDICALE, 1986, 15 (13): : 620 - 620
  • [23] ULTRASONIC GUIDANCE OF LIVER-BIOPSY AND FINE-NEEDLE ASPIRATION IN DIFFICULT CASES
    ELYADERANI, MK
    SOUTHERN MEDICAL JOURNAL, 1983, 76 (07) : 850 - 854
  • [24] DIAGNOSIS OF HEPATIC CAVERNOUS HEMANGIOMA BY FINE NEEDLE ASPIRATION BIOPSY UNDER ULTRASONIC GUIDANCE
    NAKAIZUMI, A
    IISHI, H
    YAMAMOTO, R
    KASUGAI, H
    TATSUTA, M
    OKUDA, S
    KISHIGAMI, Y
    KITAMURA, T
    GASTROINTESTINAL RADIOLOGY, 1990, 15 (01): : 39 - 42
  • [25] ULTRASONIC GUIDED PERCUTANEOUS FINE NEEDLE-BIOPSY (PFNB) OF FOCAL LESIONS IN THE LIVER
    BRET, PM
    SENTE, JM
    BRETAGNOLLE, M
    FOND, A
    LABADIE, M
    BERGER, F
    PALIARD, P
    LAMBERT, R
    GASTROENTEROLOGY, 1984, 86 (05) : 1312 - 1312
  • [26] Interstitial inflammatoryinfiltrate at renal biopsy and outcomes of class IV lupus nephritis
    Varriano, V.
    Gremese, E.
    Messuti, L.
    Costanzi, S.
    Petricca, L.
    Nowik, M.
    Gigante, M.
    Marino, G.
    Ferraccioli, G.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2015, 33 (03) : S61 - S61
  • [27] The evolving role of PET-based needle biopsy
    Seraj, Siavash Mehdizadeh
    Ayubcha, Cyrus
    Jahangiri, Pegah
    Werner, Thomas
    Alavi, Abass
    Hunt, Stephen
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [28] NEEDLE ASPIRATION BIOPSY OF MALIGNANT LUNG MASSES WITH NECROTIC CENTERS - IMPROVED SENSITIVITY WITH ULTRASONIC GUIDANCE
    PAN, JF
    YANG, PC
    CHANG, DB
    LEE, YC
    KUO, SH
    LUH, KT
    CHEST, 1993, 103 (05) : 1452 - 1456
  • [29] USE OF THIN NEEDLE-BIOPSY UNDER ULTRASONIC CONTROL IN MORPHOLOGIC DIAGNOSIS OF PERITONEAL CANCER
    TSODIKOVA, LB
    BABKIN, VP
    ARKHIV PATOLOGII, 1988, 50 (03) : 50 - 53
  • [30] PARATHYROID TUMORS-DETECTED BY FINE-NEEDLE ASPIRATION BIOPSY UNDER ULTRASONIC GUIDANCE
    SOLBIATI, L
    MONTALI, G
    CROCE, F
    BELLOTTI, E
    GIANGRANDE, A
    RAVETTO, C
    RADIOLOGY, 1983, 148 (03) : 793 - 797