Lead-selective PVC membrane electrodes based on bis(crown ether)s

被引:0
|
作者
Oh, KC
Kang, FC
Jeong, KS
Paeng, KJ [1 ]
机构
[1] Yonsei Univ, Dept Chem, Wonju 220710, South Korea
[2] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and all;aline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric Liquid membrane based on trans-18-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10(-6) and 10(-2) M, Pb2+), excellent detection limit (less than 10(-6) M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.
引用
收藏
页码:556 / 558
页数:3
相关论文
共 50 条
  • [31] Application of thiacrown ethers as ligands for lead-selective electrodes
    Radecka, H
    Radecki, J
    Dehaen, W
    ANALYTICAL SCIENCES, 1999, 15 (11) : 1109 - 1114
  • [32] BIS-CROWN ETHER DERIVATIVES AS IONOPHORES FOR POTASSIUM SELECTIVE ELECTRODES
    LINDNER, E
    TOTH, K
    HORVATH, M
    PUNGOR, E
    AGAI, B
    BITTER, I
    TOKE, L
    HELL, Z
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (02): : 157 - 163
  • [33] LEAD-SELECTIVE AND THALLIUM-SELECTIVE ELECTRODES BASED ON VANADIUM-OXIDE BRONZES
    VELIKANOVA, TV
    VOLKOV, VL
    ZHUKOVSKII, VM
    SARAPULOVA, TV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (07): : 995 - 998
  • [34] Application of Thiacrown Ethers as Ligands for Lead-Selective Electrodes
    Hanna Radecka
    Jerzy Radecki
    Wim Dehaen
    Analytical Sciences, 1999, 15 : 1109 - 1114
  • [35] THE CLINICAL-EVALUATION OF BIS CROWN ETHER BASED POTASSIUM-ION SELECTIVE ELECTRODES
    WILLIS, JP
    YOUNG, CC
    OLSONMANK, L
    RADLE, L
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1193 - 1193
  • [36] SODIUM-SELECTIVE ELECTRODES BASED ON PVC MEMBRANES CONTAINING BIS[(3N + 1)-CROWN-N] ETHER DERIVATIVES
    LUKYANENKO, NG
    TITOVA, NY
    KARPINCHIK, OS
    MELNIK, OT
    ANALYTICA CHIMICA ACTA, 1992, 259 (01) : 145 - 148
  • [37] LEAD-SELECTIVE MEMBRANE-ELECTRODE USING METHYLENE BIS(DIISOBUTYLDITHIOCARBAMATE) NEUTRAL CARRIER
    KAMATA, S
    ONOYAMA, K
    ANALYTICAL CHEMISTRY, 1991, 63 (13) : 1295 - 1298
  • [38] COATED WIRE SODIUM-SELECTIVE AND POTASSIUM-SELECTIVE ELECTRODES BASED ON BIS(CROWN ETHER) COMPOUNDS
    TAMURA, H
    KIMURA, K
    SHONO, T
    ANALYTICAL CHEMISTRY, 1982, 54 (07) : 1224 - 1227
  • [39] LEAD-SELECTIVE NEUTRAL CARRIER BASED LIQUID MEMBRANE-ELECTRODE
    LINDNER, E
    TOTH, K
    PUNGOR, E
    BEHM, F
    OGGENFUSS, P
    WELTI, DH
    AMMANN, D
    MORF, WE
    PRETSCH, E
    SIMON, W
    ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1127 - 1131
  • [40] BIS-(CROWN ETHER) ION-SELECTIVE ELECTRODES AND THEIR POTENTIAL APPLICATION
    FU, PC
    ZIC, V
    DAFFERN, M
    FEISTEL, C
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1986, 16 (04): : 328 - 329