Albumin dialysis: single pass vs. recirculation (MARS)

被引:36
|
作者
Peszynski, P [1 ]
Peters, E [1 ]
Schmidt, R [1 ]
机构
[1] Univ Rostock, Dept Internal Med, D-2500 Rostock, Germany
来源
LIVER | 2002年 / 22卷
关键词
albumin dialysis; bile acids; bilirubin; clearance; CVVH; MARS;
D O I
10.1034/j.1600-0676.2002.00007.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The single pass albumin dialysis (SPAD) was reported to be an alternative to the Molecular Adsorbent Recirculating System (MARS) for the effective removal of protein bound substances in liver failure. Three SPAD experiments using different albumin concentrations and dialysate flow rates were performed. In each experiment, 1000 ml human donor plasma, spiked with 250 mg unconjugated bilirubin, 200 mg sulfobromophthalein (BSP) and 115 mg glycocholic acid (N-[3alpha,7alpha,12alpha-trihydroxy-24-oxycholan-24-yl]glycine) - a conjugated bile acid (BA), circulated in a closed loop with 150 ml/min and was dialysed against albumin solution. These substances are bound to the different binding sites of albumin and have different association constants. For the comparison, the standard MARS experiment was performed using the same plasma flow rate of 150 ml/min. Moreover, the clearances of bilirubin for MARS and SPAD during clinical treatments were calculated using own data and those reported by Seige, Kreymann, Jeschke, et al. in Transplant Proc 1999; 31: 1371-5. The concentrations of bilirubin, BSP and BA were measured in plasma and dialysate and for these substances clearances (Cl) were calculated. It is known that the elimination rate of bilirubin is not very high during albumin dialysis in comparison to other substances, like bile acids, due to the high association constant. An increase of albumin concentration or the flow rate improved the efficacy but also raised the costs substantially. In this study, we have shown that MARS is the more effective kind of albumin dialysis for the important substances like bile acids. By SPAD an improvement of efficacy can be reached only by dramatic increase of the costs. Also, the earlier experiments showed that MARS is safer because of the removal of the stabilizers, which are normally included in the commercial albumin solutions.
引用
收藏
页码:40 / 42
页数:3
相关论文
共 50 条
  • [41] SINGLE PASS ALBUMIN DIALYSIS (SPAD) AND PLASMAPHERESIS FOR COPPER TOXICITY IN ACUTE WILSON'S DISEASE
    Teoh, Chia Wei
    Bakhsh, Shireen
    Harvey, Elizabeth
    Noone, Damien
    PEDIATRIC NEPHROLOGY, 2015, 30 (09) : 1640 - 1641
  • [42] Single pass albumin dialysis (SPAD) with Fresenius Multifiltrate system for treatment of acute liver failure
    Griskevicius, A.
    Audzijoniene, J.
    Baublys, A.
    BLOOD PURIFICATION, 2008, 26 (05) : 446 - 446
  • [43] Single-Pass Albumin Dialysis as Rescue Therapy for Pediatric Calcium Channel Blocker Overdose
    Essink, Jenna
    Berg, Sydney
    Montange, Jaka
    Sankey, Andrew
    Taylor, Veronica
    Salomon, Jeffrey
    JOURNAL OF INVESTIGATIVE MEDICINE HIGH IMPACT CASE REPORTS, 2022, 10
  • [45] Albumin dialysis MARS 2003: what evidence, how to proceed?
    Mitzner, S
    Williams, R
    LIVER INTERNATIONAL, 2003, 23 : 3 - 4
  • [46] Liver support using the albumin dialysis MARS - Update 2003
    Mitzner, SR
    PROCEEDINGS OF THE 7TH BIENNIAL CONGRESS OF THE ASIAN SOCIETY OF HEPATO-BILIARY PANCREATIC SURGERY, ASHBPS 2003, 2003, : 69 - 78
  • [47] Liver Albumin Dialysis (MARS) in Severe Valproic Acid Poisoning
    Hydzik, P.
    Wilimowska, J.
    Groszek, B.
    CLINICAL TOXICOLOGY, 2009, 47 (05) : 482 - 482
  • [48] Albumin liver dialysis (MARS) - Treatment in acute acetaminophen poisonings
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 926 - 926
  • [49] Removal of albumin bound drugs in albumin dialysis (MARS) - A new liver support system
    Majcher-Peszynska, J
    Klammt, S
    Hehl, EM
    Wacke, R
    Peszynski, P
    Stange, J
    Mitzner, S
    Schmidt, R
    Drewlow, B
    JOURNAL OF HEPATOLOGY, 2000, 32 : 60 - 60
  • [50] Removal of albumin bound drugs in albumin dialysis (MARS) - a new liver support system
    Peszynski, P.
    Majcher-Peszynska, J.
    Klammt, S.
    Hehl, E.-M.
    Wacke, R.
    Stange, J.
    Mitzner, S.
    Schmidt, R.
    Drewelow, B.
    ASAIO Journal, 2000, 46 (02)